Nonenhanced Arterial Spin Labeled Carotid MR Angiography Using Three-Dimensional Radial Balanced Steady-State Free Precession Imaging

被引:17
|
作者
Koktzoglou, Ioannis [1 ,2 ]
Meyer, Joel R. [1 ,2 ]
Ankenbrandt, William J. [1 ,2 ]
Giri, Shivraman [3 ]
Piccini, Davide [4 ,5 ,6 ]
Zenge, Michael O. [7 ]
Flanagan, Oisin [1 ,8 ]
Desai, Tina [2 ,9 ]
Gupta, NavYash [2 ,9 ]
Edelman, Robert R. [1 ,8 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
[3] Siemens Healthcare, Chicago, IL USA
[4] Siemens Healthcare IM BM PI, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[6] Univ Lausanne UNIL, Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[7] Siemens AG, Healthcare Sect, MR Prod Innovat & Definit, Erlangen, Germany
[8] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[9] NorthShore Univ HealthSyst, Dept Surg, Evanston, IL 60201 USA
关键词
carotid; angiography; arterial spin labeling; radial; nonenhanced; INVERSION-RECOVERY; CONTRAST; STENOSIS;
D O I
10.1002/jmri.24640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. Materials and MethodsThe carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of approximate to 4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. ResultsUsing hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in 2 min. ConclusionNonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1150 / 1156
页数:7
相关论文
共 50 条
  • [1] Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
    Han, Paul Kyu
    Marin, Thibault
    Zhuo, Yue
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 126 - 132
  • [2] Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling
    Han, Paul Kyu
    Ye, Jong Chul
    Kim, Eung Yeop
    Choi, Seung Hong
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2016, 29 (03) : 264 - 274
  • [3] Fast projective carotid MR angiography using arterial spin-labeled balanced SSFP
    Koktzoglou, Ioannis
    Edelman, Robert R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) : 778 - 782
  • [4] FMRI using balanced steady-state free precession (SSFP)
    Miller, Karla L.
    NEUROIMAGE, 2012, 62 (02) : 713 - 719
  • [5] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [6] Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession
    Park, Sung-Hong
    Han, Paul Kyu
    Choi, Seung Hong
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (03) : 550 - 559
  • [7] Multiple Repetition Time Balanced Steady-State Free Precession Imaging
    Cukur, Tolga
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 193 - 204
  • [8] Flow Targeted 3D Steady-State Free-Precession Coronary MR Angiography Comparison of Three Different Imaging Approaches
    Katoh, Marcus
    Spuentrup, Elmar
    Stuber, Matthias
    Buecker, Arno
    Manning, Warren J.
    Guenther, Rolf W.
    Botnar, Rene M.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (12) : 757 - 762
  • [9] Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla
    Koktzoglou, Ioannis
    Walker, Matthew T.
    Meyer, Joel R.
    Murphy, Ian G.
    Edelman, Robert R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [10] Nonenhanced Extracranial Carotid MR Angiography Using Arterial Spin Labeling: Improved Performance With Pseudocontinuous Tagging
    Koktzoglou, Ioannis
    Gupta, NavYash
    Edelman, Robert R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (02) : 384 - 394