DFIG rotor voltage control for system dynamic performance enhancement

被引:26
作者
Rahim, A. H. M. A. [1 ]
Habiballah, I. O. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Elect Engn, Dhahran 31261, Saudi Arabia
关键词
Wind power generation; Doubly fed induction generator (DFIG); Converter controls of NIG; POD controller; FED INDUCTION GENERATOR; POWER-SYSTEM; WIND TURBINES; SPEED; DESIGN; DRIVEN;
D O I
10.1016/j.epsr.2010.10.014
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article develops a model of a doubly fed induction generator system including the detailed dynamics of the converter circuitry. The order of the converter controls in terms of providing damping to the system is identified through residue principles. Supplementary damping controller has been incorporated so as to compensate for the phase lag introduced by the rotor voltage input, which was observed to have the largest residue contribution at the lightly damped mode. The improvement in damping profile was verified by simulating the system for a number of disturbance conditions. While the power oscillation damping (POD) controller was observed to enhance the system damping generally, it was also able to ride through low voltage conditions arising out of severe fault conditions thus averting total system collapse. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:503 / 509
页数:7
相关论文
共 24 条
[1]   Control design and dynamic performance analysis of a wind turbine-induction generator unit [J].
Abdin, ES ;
Xu, W .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2000, 15 (01) :91-96
[2]   Damping controller design for power system oscillations using global signals [J].
AboulEla, ME ;
Sallam, AA ;
McCalley, JD ;
Fouad, AA .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1996, 11 (02) :767-773
[3]   Analytical determination of steady-state converter control laws for wind turbines equipped with doubly fed induction generators [J].
Aguglia, D. ;
Viarouge, P. ;
Wamkeue, R. ;
Cros, J. .
IET RENEWABLE POWER GENERATION, 2008, 2 (01) :16-25
[4]   Provision of a synchronising power characteristic on DFIG-based wind farms [J].
Anaya-Lara, O. ;
Hughes, F. M. ;
Jenkins, N. ;
Strbac, G. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2007, 1 (01) :162-169
[5]   Network power flux control of a wind generator [J].
Aouzellag, D. ;
Ghedamsi, K. ;
Berkouk, E. M. .
RENEWABLE ENERGY, 2009, 34 (03) :615-622
[6]   Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm [J].
Cartwright, P ;
Holdsworth, L ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (04) :495-502
[7]   Variable-speed wind power generation using doubly fed wound rotor induction machine - A comparison with alternative schemes [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (03) :414-421
[8]   On the stability of power systems containing doubly fed induction generator-based generation [J].
Elkington, Katherine ;
Enazkins, Valerijs ;
Ghandhari, Mehrdad .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (09) :1477-1484
[9]   Impact of wind farms on a power system.: An eigenvalue analysis approach [J].
Fernandez, R. D. ;
Mantz, R. J. ;
Battaiotto, P. E. .
RENEWABLE ENERGY, 2007, 32 (10) :1676-1688
[10]  
Heier S., 2007, Grid Integration of Wind Energy Conversion Systems, V2nd