Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review

被引:16
作者
Lee, Roger [1 ,2 ]
James, Carole [1 ,3 ]
Edwards, Suzi [4 ]
Skinner, Geoff [5 ]
Young, Jodi L. [6 ]
Snodgrass, Suzanne J. [1 ,2 ]
机构
[1] Univ Newcastle, Sch Hlth Sci, Newcastle, NSW 2308, Australia
[2] Univ Newcastle, Ctr Brain & Mental Hlth Res, Newcastle, NSW 2308, Australia
[3] Univ Newcastle, Ctr Resources Hlth & Safety, Newcastle, NSW 2308, Australia
[4] Univ Sydney, Sch Hlth Sci, Sydney, NSW 2006, Australia
[5] Univ Newcastle, Sch Informat & Phys Sci, Newcastle, NSW 2308, Australia
[6] Bellin Coll, Dept Phys Therapy, Green Bay, WI 54311 USA
关键词
wearable devices; posture; industrial/workplace ergonomics; feedback; TIME POSTURAL BIOFEEDBACK; MONOTONOUS KEYBOARD WORK; MUSCULOSKELETAL DISORDERS; RISK-FACTORS; OFFICE WORKERS; MEASUREMENT UNIT; MUSCLE-ACTIVITY; CERVICAL-SPINE; GLOBAL BURDEN; NECK PAIN;
D O I
10.3390/s21196377
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Wearable inertial sensor technology (WIST) systems provide feedback, aiming to modify aberrant postures and movements. The literature on the effects of feedback from WIST during work or work-related activities has not been previously summarised. This review examines the effectiveness of feedback on upper body kinematics during work or work-related activities, along with the wearability and a quantification of the kinematics of the related device. Methods: The Cinahl, Cochrane, Embase, Medline, Scopus, Sportdiscus and Google Scholar databases were searched, including reports from January 2005 to July 2021. The included studies were summarised descriptively and the evidence was assessed. Results: Fourteen included studies demonstrated a 'limited' level of evidence supporting posture and/or movement behaviour improvements using WIST feedback, with no improvements in pain. One study assessed wearability and another two investigated comfort. Studies used tri-axial accelerometers or IMU integration (n = 5 studies). Visual and/or vibrotactile feedback was mostly used. Most studies had a risk of bias, lacked detail for methodological reproducibility and displayed inconsistent reporting of sensor technology, with validation provided only in one study. Thus, we have proposed a minimum 'Technology and Design Checklist' for reporting. Conclusions: Our findings suggest that WIST may improve posture, though not pain; however, the quality of the studies limits the strength of this conclusion. Wearability evaluations are needed for the translation of WIST outcomes. Minimum reporting standards for WIST should be followed to ensure methodological reproducibility.
引用
收藏
页数:37
相关论文
共 183 条
  • [1] Exploring the Role of Wearable Technology in Sport Kinematics and Kinetics: A Systematic Review
    Adesida, Yewande
    Papi, Enrica
    McGregor, Alison H.
    [J]. SENSORS, 2019, 19 (07)
  • [2] Sit-stand workstations and impact on low back discomfort: a systematic review and meta-analysis
    Agarwal, Shuchi
    Steinmaus, Craig
    Harris-Adamson, Carisa
    [J]. ERGONOMICS, 2018, 61 (04) : 538 - 552
  • [3] Ahmad N., 2013, INT J SIGNAL PROCESS, V1, P256, DOI [DOI 10.12720/IJSPS.1.2.256-262, 10.12720/ijsps.1.2.256-262]
  • [4] Influence of the wearable posture correction sensor on head and neck posture:Sitting and standing workstations
    Ailneni, Ravi Charan
    Syamala, Kartheek Reddy
    Kim, In-Sop
    Hwang, Jaejin
    [J]. WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2019, 62 (01): : 27 - 35
  • [5] Efficacy of virtual reality to reduce chronic low back pain: Proof-of-concept of a non-pharmacological approach on pain, quality of life, neuropsychological and functional outcome
    Alemanno, Federica
    Houdayer, Elise
    Emedoli, Daniele
    Locatelli, Matteo
    Mortini, Pietro
    Mandelli, Carlo
    Raggi, Alberto
    Iannaccone, Sandro
    [J]. PLOS ONE, 2019, 14 (05):
  • [6] Validation of a Helmet-Based System to Measure Head Impact Biomechanics in Ice Hockey
    Allison, Mari A.
    Kang, Yun Seok
    Bolte, John H.
    Maltese, Matthew R.
    Arbogast, Kristy B.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (01) : 115 - 123
  • [7] Validation of tri-axial accelerometer for the calculation of elevation angles
    Amasay, Tal
    Zodrow, Keely
    Kincl, Laurel
    Hess, Jennifer
    Karduna, Andrew
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2009, 39 (05) : 783 - 789
  • [8] Risk factors in the onset of neck/shoulder pain in a prospective study of workers in industrial and service companies
    Andersen, JH
    Kaergaard, A
    Mikkelsen, S
    Jensen, UF
    Frost, P
    Bonde, JP
    Fallentin, N
    Thomsen, JF
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2003, 60 (09) : 649 - 654
  • [9] [Anonymous], 2018, P 1 INT C HUM SYST E
  • [10] [Anonymous], 2016, MAN THER, DOI DOI 10.1016/J.MATH.2016.05.323