Combined phenyl silane and immunoaffinity column cleanup with liquid chromatography for determination of ochratoxin A in roasted coffee: Collaborative study

被引:0
|
作者
Entwisle, AC
Williams, AC
Mann, PJ
Russell, J
Slack, PT
Gilbert, J
机构
[1] Leatherhead Food Res Assoc, Leatherhead KT22 7RY, Surrey, England
[2] Minist Agr Fisheries & Food, Cent Sci Lab, York YO41 1LZ, N Yorkshire, England
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A collaborative study was conducted to evaluate a liquid chromatography (LC) method for ochratoxin A using sequential phenyl silane and immunoaffinity column cleanup, The method was tested at 3 different levels of ochratoxin A in roasted coffee, which spanned the range of possible future European regulatory limits, The test portion was extracted with methanol and sodium bicarbonate by shaking for 30 min, The extract was filtered, centrifuged, and then cleaned Lap on a phenyl silane column before being eluted from the washed column with methanol-water. The eluate was diluted with phosphate-buffered saline (PBS) and applied to an ochratoxin A immunoaffinity column, which was washed with water. The ochratoxin A was eluted with methanol, the solvent was evaporated, and the residue was redissolved in injection solvent, After injection of this solution onto a reversed-phase LC apparatus, ochratoxin A was measured by fluorescence detection, Eight laboratory samples of low-level naturally contaminated roasted coffee and 2 laboratory samples of blank coffee (< 0.2 ng/g ochratoxin A at the signal-to-noise ratio of 3:1), along with ampules of ochratoxin A calibrant and:spiking solutions, were sent to 15 laboratories in 13 different European countries, Test portions of the laboratory samples were spiked at levels of 4 ng/g ochratoxin A, and recoveries ranged from 65 to 97%. Based on results for Spiked blank material (blind duplicates) and naturally contaminated material (blind duplicates at 3 levels), the relative standard deviation for repeatability (RSDr) ranged from 2 to 22% and the relative standard deviation for reproducibility (RSDR) ranged from 14 to 26%. The method showed acceptable within- and between-laboratory precision, as evidenced by HORRAT values, at the low lever of determination for ochratoxin A in roasted coffee.
引用
收藏
页码:444 / 450
页数:7
相关论文
共 50 条
  • [21] Verifying the performance in the determination of ochratoxin by immunoaffinity column cleanup and high performance liquid chromatography in a laboratory using single laboratory validation
    Mendes de Souza, Maria de Lourdes
    Goncalves, Elisabeth Borges
    Silva, Otniel Freitas
    de Farias, Antonio Xavier
    da Silva Cavalcanti, Anderson Luis
    CIENCIA E TECNOLOGIA DE ALIMENTOS, 2010, 30 : 197 - 204
  • [22] Immunoaffinity column clean-up and thin layer chromatography for determination of ochratoxin A in green coffee
    Santos, EA
    Vargas, EA
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2002, 19 (05): : 447 - 458
  • [23] Determination of Ochratoxin A in Pig Kidneys by Immunoaffinity Cleanup and Ultra-High Performance Liquid Chromatography
    Hou, YaLi
    Zhou, Jinhui
    Li, YuPing
    Xie, JiangHua
    Zhou, Li
    Lv, FengLin
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (06) : 1566 - 1570
  • [24] Ochratoxin A in roasted coffee marketed in Czech Republic: determination by liquid chromatography and fluorescence detection
    Pernica, Marek
    Martinik, Jan
    Bosko, Rastislav
    Svoboda, Zdenek
    Cwikova, Olga
    Belakova, Sylvie
    Benesova, Karolina
    JOURNAL OF FOOD AND NUTRITION RESEARCH, 2023, 62 (02): : 191 - 197
  • [25] Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxin B1 in cattle feed:: Collaborative study
    Stroka, J
    Von Holst, C
    Anklam, E
    Reutter, M
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (06) : 1179 - 1186
  • [26] Immunoaffinity column cleanup with liquid chromatography using post-column bromination for determination of aflatoxin B1 in cattle feed: Collaborative study
    Stroka, Joerg
    Von Holst, Christoph
    Anklam, Elke
    Reutter, Matthias
    Anklam, E. (elke.anklam@cec.eu.int), 1600, AOAC International (86):
  • [27] Simultaneous determination of aflatoxins, ochratoxin A, and zearalenone in grains by new immunoaffinity column/liquid chromatography
    Göbel, R
    Lusky, K
    JOURNAL OF AOAC INTERNATIONAL, 2004, 87 (02) : 411 - 416
  • [28] Simultaneous determination of aflatoxins, ochratoxin A, and zearalenone in grains by new immunoaffinity column/liquid chromatography
    Göbel, Roswitha
    Lusky, Klaus
    Journal of AOAC International, 1600, 87 (02): : 411 - 416
  • [29] Determination of fumonisins B1 and B2 in corn and corn flakes by liquid chromatography with immunoaffinity column cleanup:: Collaborative study
    Visconti, A
    Solfrizzo, M
    De Girolamo, A
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (06) : 1828 - 1837
  • [30] Determination of aflatoxin B1 in baby food (infant formula) by immunoaffinity column cleanup liquid chromatography with postcolumn bromination:: Collaborative study
    Stroka, J
    Anklam, E
    Joerissen, U
    Gilbert, J
    JOURNAL OF AOAC INTERNATIONAL, 2001, 84 (04) : 1116 - 1123