Detection of granulocyte-reactive antibodies: a comparison of different methods

被引:17
作者
Heinzl, M. W. [1 ]
Schoenbacher, M. [1 ]
Dauber, E-M [1 ]
Panzer, S. [1 ]
Mayr, W. R. [1 ]
Koermoeczi, G. F. [1 ]
机构
[1] Med Univ Vienna, Dept Blood Grp Serol & Transfus Med, A-1090 Vienna, Austria
关键词
flow cytometry; granulocyte immunology; granulocyte-reactive antibodies; human neutrophil antigens; microbeads assay; ACUTE LUNG INJURY; TRANSFUSION REACTIONS; LEUKOCYTE ANTIBODIES; BLOOD-DONORS; ANTIGEN; ALLOANTIBODIES;
D O I
10.1111/vox.12227
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and ObjectivesGranulocyte-reactive antibodies can cause autoimmune and neonatal immune neutropenias as well as transfusion-related acute lung injury. The classical antibody-detection methods granulocyte aggregation test (GAT), granulocyte immunofluorescence test (GIFT) and monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA) are time-consuming and technically challenging. In recent years, flow cytometric white blood cell immunofluorescence test (Flow-WIFT) and the microbeads assay LabScreen (R) Multi have emerged and are still subject of evaluation. These serological tests were compared on a screening and specification level. Materials and MethodsFor screening, the combination of GAT/GIFT was compared to Flow-WIFT testing 333 samples. Positive samples were further analysed with MAIGA and LabScreen (R) Multi. ResultsGranulocyte aggregation test/GIFT detected 77 positive samples, Flow-WIFT found 108 granulocyte-reactive samples. Six Samples were only positive in GAT/GIFT, and 37 samples were only positive in Flow-WIFT (=0682). Antibody specification with MAIGA and the microbeads assay confirmed granulocyte-reactivity in 83 cases with 70 matching results (=0742). However, out of six detected human neutrophil antigen (HNA) reactivities only two specificities matched in both assays. ConclusionFlow-WIFT may be a valuable addition to GIFT for granulocyte-reactive antibody screening. MAIGA remains the most reliable laboratory method for antibody specification.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 21 条
  • [1] Recommendations of the ISBT Working Party on Granulocyte Immunobiology for leucocyte antibody screening in the investigation and prevention of antibody-mediated transfusion-related acute lung injury
    Bierling, P.
    Bux, J.
    Curtis, B.
    Flesch, B.
    Fung, I.
    Lucas, G.
    Macek, M.
    Muniz-Diaz, E.
    Porcelijn, I.
    Reil, A.
    Sachs, U.
    Schuller, R.
    Tsuno, N.
    Uhrynowska, M.
    Urbaniak, S.
    Valentin, N.
    Wikman, A.
    Zupanska, B.
    [J]. VOX SANGUINIS, 2009, 96 (03) : 266 - 269
  • [2] Human neutrophil alloantigens
    Bux, J.
    [J]. VOX SANGUINIS, 2008, 94 (04) : 277 - 285
  • [3] Antibody-mediated (immune) transfusion-related acute lung injury
    Bux, J.
    [J]. VOX SANGUINIS, 2011, 100 (01) : 122 - 128
  • [4] ANALYSIS OF GRANULOCYTE-REACTIVE ANTIBODIES USING AN IMMUNOASSAY BASED UPON MONOCLONAL-ANTIBODY-SPECIFIC IMMOBILIZATION OF GRANULOCYTE ANTIGENS
    BUX, J
    KOBER, B
    KIEFEL, V
    MUELLERECKHARDT, C
    [J]. TRANSFUSION MEDICINE, 1993, 3 (02) : 157 - 162
  • [5] Granulocyte antibody screening: evaluation of a bead-based assay in comparison with classical methods
    Fromont, Patricia
    Prie, Nolwen
    Simon, Philippe
    Cesbron-Gautier, Anne
    Quelvennec, Erwann
    Bignon, Jean-Denis
    Muller, Jean-Yves
    Audrain, Marie
    [J]. TRANSFUSION, 2010, 50 (12) : 2643 - 2648
  • [6] Neutrophil antibody diagnostics and screening: review of the classical versus the emerging
    Fung, Y. L.
    Minchinton, R. M.
    Fraser, J. F.
    [J]. VOX SANGUINIS, 2011, 101 (04) : 282 - 290
  • [7] MICRO-TECHNIQUE FOR DETECTION OF LEUKOCYTE AGGLUTININS
    JIANG, AF
    LALEZARI, P
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1975, 7 (01) : 103 - 108
  • [8] The German Haemovigilance System-reports of serious adverse transfusion reactions between 1997 and 2007
    Keller-Stanislawski, B.
    Lohmann, A.
    Guenay, S.
    Heiden, M.
    Funk, M. B.
    [J]. TRANSFUSION MEDICINE, 2009, 19 (06) : 340 - 349
  • [9] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174
  • [10] External quality assessment of human neutrophil antigen (HNA)-specific antibody detection and HNA genotyping from 2000 to 2012
    Lucas, G.
    Porcelijn, L.
    Fung, Y. L.
    Green, F.
    Reil, A.
    Hopkins, M.
    Schuller, R.
    Green, A.
    de Haas, M.
    Bux, J.
    [J]. VOX SANGUINIS, 2013, 105 (03) : 259 - 269