Robotics, imaging, and artificial intelligence in the catheterisation laboratory

被引:18
作者
Beyar, Rafael [1 ,2 ]
Davies, Justin E. [3 ]
Cook, Christopher [4 ]
Dudek, Dariusz [5 ,6 ]
Cummins, Paul A. [7 ]
Bruining, Nico [8 ]
机构
[1] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, B 9602,Rambam Hlth Care Campus, IL-3109601 Haifa, Israel
[2] Rambam Hlth Care Campus, Haifa, Israel
[3] Imperial Coll NHS Trust, Hammersmith Hosp, London, England
[4] Essex Cardiothorac Ctr, Basildon, Essex, England
[5] Jagiellonian Univ Med Coll, Inst Cardiol, Krakow, Poland
[6] Maria Cecilia Hosp, GVM Care & Res, Cotignola, RA, Italy
[7] Erasmus MC, Dept Cardiol, Rotterdam, Netherlands
[8] Erasmus MC, Dept Cardiol, Thoraxctr, Clin Epidemiol & Innovat, Rotterdam, Netherlands
关键词
fractional flow reserve; miscellaneous; non-invasive imaging; other techniques; QCA; PERCUTANEOUS CORONARY INTERVENTION; MAGNETIC NAVIGATION SYSTEM; INTRAVASCULAR ULTRASOUND; RADIATION SAFETY; FEASIBILITY; FUTURE; ANGIOGRAPHY; CARDIOLOGY; PLAQUE; ANGIOPLASTY;
D O I
10.4244/EIJ-D-21-00145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The catheterisation laboratory today combines diagnosis and therapeutics, through various imaging modali-ties and a prolific list of interventional tools, led by balloons and stents. In this review, we focus primarily on advances in image-based coronary interventions. The X-ray images that are the primary modality for diagnosis and interventions are combined with novel tools for visualisation and display, including multi-imaging co-registration modalities with three-and four-dimensional presentations. Interpretation of the physiologic significance of coronary stenosis based on prior angiographic images is being explored and implemented. Major efforts to reduce X-ray exposure to the staff and the patients, using computer-based algorithms for image processing, and novel methods to limit the radiation spread are being explored. The use of artificial intelligence (AI) and machine learning for better patient care requires attention to univer-sal methods for sharing and combining large data sets and for allowing interpretation and analysis of large cohorts of patients. Barriers to data sharing using integrated and universal protocols should be overcome to allow these methods to become widely applicable. Robotic catheterisation takes the physician away from the ionising radiation spot, enables coronary angioplasty and stenting without compromising safety, and may allow increased precision. Remote coronary procedures over the internet, that have been explored in virtual and animal studies and already applied to patients in a small pilot study, open possibilities for shar-ing experience across the world without travelling. Application of those technologies to neurovascular, and particularly stroke interventions, may be very timely in view of the need for expert neuro-interventionalists located mostly in central areas.
引用
收藏
页码:537 / 549
页数:13
相关论文
共 89 条
[1]   Rotate-on-Retract Procedural Automation for Robotic-Assisted Percutaneous Coronary Intervention: First Clinical Experience [J].
Al Nooryani, Arif ;
Aboushokka, Wael .
CASE REPORTS IN CARDIOLOGY, 2018, 2018
[2]   The Role of the FDA in Ensuring the Safety and Efficacy of Artificial Intelligence Software and Devices [J].
Allen, Bibb .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2019, 16 (02) :208-210
[3]   Robotically performed excimer laser coronary atherectomy: Proof of feasibility [J].
Almasoud, Abdullah ;
Walters, Daniel ;
Mahmud, Ehtisham .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (04) :713-716
[4]   3D advanced imaging overlay with rapid registration in CHD to reduce radiation and assist cardiac catheterisation interventions [J].
Arar, Yousef ;
Reddy, Surendranath R. Veeram ;
Kim, Heidi ;
Dimas, V. Vivian ;
Zellers, Thomas M. ;
Abou Zahr, Riad ;
Vamsee, Ravi ;
Greer, Joshua S. ;
Tandon, Animesh ;
Pontiki, Antonia ;
Dillenbeck, Jeanne ;
Zabala, Luis ;
Greil, Gerald ;
Nugent, Alan W. ;
Hussain, Tarique .
CARDIOLOGY IN THE YOUNG, 2020, 30 (05) :656-662
[5]   An artificial intelligence-enabled ECG algorithm for the identification of patients with atrial fibrillation during sinus rhythm: a retrospective analysis of outcome prediction [J].
Attia, Zachi, I ;
Noseworthy, Peter A. ;
Lopez-Jimenez, Francisco ;
Asirvatham, Samuel J. ;
Deshmukh, Abhishek J. ;
Gersh, Bernard J. ;
Carter, Rickey E. ;
Yao, Xiaoxi ;
Rabinstein, Alejandro A. ;
Erickson, Brad J. ;
Kapa, Suraj ;
Friedman, Paul A. .
LANCET, 2019, 394 (10201) :861-867
[6]  
Balter S, 1999, CATHETER CARDIO INTE, V47, P347, DOI 10.1002/(SICI)1522-726X(199907)47:3<347::AID-CCD23>3.0.CO
[7]  
2-N
[8]   Significant radiation reduction in interventional fluoroscopy using a novel eye controlled movable region of interest [J].
Balter, Stephen ;
Simon, Dan ;
Itkin, Max ;
Granada, Juan F. ;
Melman, Haim ;
Dangas, George .
MEDICAL PHYSICS, 2016, 43 (03) :1531-1538
[9]   Calcium detection, its quantification, and grayscale morphology-based risk stratification using machine learning in multimodality big data coronary and carotid scans: A review [J].
Banchhor, Sumit K. ;
Londhe, Narendra D. ;
Araki, Tadashi ;
Saba, Luca ;
Radeva, Petia ;
Khanna, Narendra N. ;
Suri, Jasjit S. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 101 :184-198
[10]   Remote-control percutaneous coronary interventions - Concept, validation, and first-in-humans pilot clinical trial [J].
Beyar, R ;
Gruberg, L ;
Deleanu, D ;
Roguin, A ;
Almagor, Y ;
Cohen, S ;
Kumar, G ;
Wenderow, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) :296-300