Abdominal MR Imaging at 3.0 T

被引:69
作者
Akisik, Fatih M. [1 ]
Sandrasegaran, Kumaresan [1 ]
Aisen, Alex M. [1 ]
Lin, Chen [1 ]
Lall, Chandana [1 ]
机构
[1] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
关键词
D O I
10.1148/rg.275075023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance ( MR) imaging at 3.0 T offers an improved signal-to-noise ratio compared with that at 1.5 T. However, the physics of high field strength also brings disadvantages, such as increases in the specific absorption rate, in magnetic field inhomogeneity effects, and in susceptibility artifacts. The use of 3.0-T MR imaging for abdominal evaluations, in particular, has lagged behind that for other applications because of the difficulty of imaging a large volume while compensating for respiratory motion. At a minimum, abdominal MR imaging at 3.0 T requires modifications in the pulse sequences used at 1.5 T. Such modifications may include a decrease in the flip angle used for refocusing pulses and an increase in the repetition time for T1-weighted acquisitions. In addition, parallel imaging and other techniques ( hyperecho sequences, transition between pseudo steady states) may be used to maintain a high signal-to-noise ratio while decreasing acquisition time and minimizing the occurrence of artifacts on abdominal MR images. (c) RSNA, 2007
引用
收藏
页码:1433 / 1444
页数:12
相关论文
共 20 条
  • [1] Bammer Roland, 2004, Top Magn Reson Imaging, V15, P129, DOI 10.1097/01.rmr.0000139666.23921.27
  • [2] Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
  • [3] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [4] THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
    EDELSTEIN, WA
    GLOVER, GH
    HARDY, CJ
    REDINGTON, RW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) : 604 - 618
  • [5] Increased diffusion sensitivity with hyperechos
    Frank, LR
    Wong, EC
    Liu, TT
    Buxton, RB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) : 1098 - 1105
  • [6] Magnetic resonance imaging at 3.0 Tesla: Challenges and advantages in clinical neurological imaging
    Frayne, R
    Goodyear, BG
    Dickhoff, P
    Lauzon, ML
    Sevick, RJ
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (07) : 385 - 402
  • [7] Parallel MR imaging: A user's guide
    Glockner, JF
    Hu, HH
    Stanley, DW
    Angelos, L
    King, K
    [J]. RADIOGRAPHICS, 2005, 25 (05) : 1279 - 1297
  • [8] Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)
    Hennig, J
    Weigel, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 527 - 535
  • [9] Hyperechoes
    Hennig, J
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) : 6 - 12
  • [10] Hussain Shahid M, 2005, Top Magn Reson Imaging, V16, P325, DOI 10.1097/01.rmr.0000224689.06501.16