Assessing local tissue edema in postmastectomy lymphedema

被引:1
作者
Mayrovitz, H. N. [1 ]
机构
[1] Nova SE Univ, Coll Med Sci, Ft Lauderdale, FL 33328 USA
关键词
breast cancer; lymphedema measurement; edema measurement;
D O I
暂无
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Overall limb lymphedema can be assessed by several methods but none are suitable to determine local edema. Quantifying local edema could provide important information not previously available. Our goal was to determine the suitability of using the tissue dielectric constant (TDC) as and index of local tissue water to detect and quantify edema in postmastectomy patients with unilateral arm lymphedema. Segmental arm volume and TDC were measured in both arms of 18 women with unilateral lymphedema, and in 15 premenopausal and 15 postmenopausal controls. TDC was measured at a frequency of 300 MHz using open-ended coaxial probes with effective measuring depths of 0.5, 1.5, 2.5 and 5.0 mm. For patients and controls, absolute TDC depended on measurement depth but for any depth the TDC of lymphedematous segments was significantly greater than for non-affected contralateral arms (p<0.001). At a depth of 2.5 mm, the TDC ratio between arms for patients was 1.64 +/- 0.30 vs. 1.04 +/- 0.04 for both control groups (p<0.001). No patient's TDC ratio was as low as 1.2 and no control subject's TDC ratio was as great as 1.2. Results suggest that this method is a good quantitative discriminator of the presence of lymphedema in patients with unilateral limb lymphedema.
引用
收藏
页码:87 / 94
页数:8
相关论文
共 25 条
  • [1] Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe
    Aimoto, A
    Matsumoto, T
    [J]. MEDICAL ENGINEERING & PHYSICS, 1996, 18 (08) : 641 - 646
  • [2] Variational formulation of open-ended coaxial line in contact with layered biological medium
    Alanen, E
    Lahtinen, T
    Nuutinen, J
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (10) : 1241 - 1248
  • [3] Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensors
    Alanen, E
    Lahtinen, T
    Nuutinen, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) : 475 - 485
  • [4] Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements
    Alanen, E
    Lahtinen, T
    Nuutinen, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) : N169 - N176
  • [5] BATES DO, 1992, INT J MICROCIRC, V11, P359
  • [6] CASLEYSMITH JR, 1994, LYMPHOLOGY, V27, P56
  • [7] A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases
    Cornish, BH
    Thomas, BJ
    Ward, LC
    Hirst, C
    Bunce, IH
    [J]. ANGIOLOGY, 2002, 53 (01) : 41 - 47
  • [8] Cornish BH, 2001, LYMPHOLOGY, V34, P2
  • [9] Concurrent validity of upper-extremity volume estimates: Comparison of calculated volume derived from girth measurements and water displacement volume
    Karges, JR
    Mark, BE
    Stikeleather, SJ
    Worrell, TW
    [J]. PHYSICAL THERAPY, 2003, 83 (02): : 134 - 145
  • [10] The distribution of oedema in the lower limb of patients with chronic critical limb ischaemia: a study with computed tomography
    Khiabani, HZ
    Anvar, MD
    Rostad, B
    Stranden, E
    Kroese, AJ
    [J]. VASA-JOURNAL OF VASCULAR DISEASES, 1999, 28 (04): : 265 - 270