Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique in transcatheter aortic valve-in-valve procedures: a single-center initial experience

被引:4
|
作者
Tagliari, Ana Paula [1 ,2 ]
Miura, Mizuki [1 ]
Gavazzoni, Mara [1 ]
Haager, Philipp K. [3 ]
Russo, Giulio [1 ]
Pozzoli, Alberto [1 ]
Zuber, Michel [1 ]
Jorg, Lucas [3 ]
Rickli, Hans [3 ]
Gennari, Marco [1 ]
Maisano, Francesco [1 ]
Taramasso, Maurizio [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Cardiac Surg Dept, Zurich, Switzerland
[2] Univ Fed Rio Grande do Sul, Fac Med, Postgrad Program Hlth Sci Cardiol & Cardiovasc Sc, Porto Alegre, RS, Brazil
[3] Kantonsspital St Gallen, Cardiol Dept, St Gallen, Switzerland
关键词
bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique; coronary artery obstruction; structural heart disease; transcatheter aortic valve implantation; COMPUTED-TOMOGRAPHY; CLINICAL-OUTCOMES; IMPLANTATION; REPLACEMENT; PROTECTION; INSIGHTS; TAVR; PREDICTORS; OCCLUSION;
D O I
10.2459/JCM.0000000000001104
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To describe six cases using the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique to prevent coronary artery obstruction during transcatheter aortic valve-in-valve procedures. Methods All patients presented degeneration of a bovine pericardium bioprosthesis [four Trifecta (19, 21, 23, and 25 mm); two Mitroflow (25 and 27 mm)] resulting in severe aortic stenosis (n = 5) or severe aortic regurgitation (n = 1). Procedures were performed under fluoroscopic and echocardiography guidance, and the transfemoral access was used to deliver a self-expanding valve. Data are expressed as frequency or median (Q(1)-Q(3)). Results Age, EuroScore II, and Society of Thoracic Surgeons score were 81 years (75-83.2), 2.9% (2.6-10.7), and 2.7% (2.3-3.2), respectively. Median left and right coronary heights were 9.1 mm (6.2-10.3) and 12.4 mm (10-13.5), respectively, with a median virtual transcatheter heart valve-to-coronary distance of 2.9 mm on the left and 4.6 mm on the right side. Isolated left leaflet laceration was planned in four patients, and bileaflet in two. One unsuccessful right leaflet laceration was reported, corresponding to the first patient (success rate 87.5%). All other seven leaflets lacerations were successfully performed, with no intraprocedure complications. No coronary obstruction, in-hospital death, valve complication, cardiovascular event, or pacemaker implantation were reported. All patients are being followed in routine outpatient visits, and no adverse events were registered. Conclusion The high procedural success and low complication rate reported in this initial experience, demonstrates that the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique can be a viable solution to prevent coronary obstruction in selected patients undergoing valve-in-valve procedures. Operator experience, periprocedural imaging and teamwork are essential to enable an accurate and successful procedure.
引用
收藏
页码:212 / 221
页数:10
相关论文
共 50 条
  • [31] Transcatheter Valve Implantation for Failed Surgical Aortic and Mitral Bioprostheses: A Single-Center Experience
    Lipinski, Jerry
    Patel, Sandeep M.
    Patel, Toral R.
    Kobe, Daniel
    Saric, Petar
    Panhwar, Muhammad
    Nadeem, Fahd
    Li, Jun
    Clevenger, Joshua R.
    Ichibori, Yasuhiro
    Fares, Anas
    Lang, Katherine
    Bezerra, Hiram G.
    Sareyyupoglu, Basar
    Medalion, Benjamin
    Deo, Salil
    Elgudin, Yakov
    Markowitz, Alan
    Simon, Daniel, I
    Costa, Marco A.
    Kalra, Ankur
    Attizzani, Guilherme F.
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (05) : 186 - +
  • [32] Evaluation of procedural and clinical outcomes of transcatheter aortic valve implantation: A single-center experience
    Karaduman, Bilge Duran
    Ayhan, Huseyin
    Keles, Telat
    Bozkurt, Engin
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2020, 23 (05) : 288 - 296
  • [33] Transcatheter aortic valve replacement in atypical valve anatomy using the Lotus valve A Chinese single-center experience
    Xu, Q.
    Liu, X.
    Jiang, J.
    He, Y.
    Zhu, Q.
    Gao, F.
    Du, F.
    He, W.
    Cheng, J.
    Kong, M.
    Pu, Z.
    Zhou, Q.
    Gooley, R.
    Wang, J.
    HERZ, 2021, 46 (01) : 63 - 70
  • [34] Comparison Between Transcatheter and Surgical Aortic Valve Replacement: A Single-Center Experience
    Silberman, Shuli
    Abu Akr, Firas
    Bitran, Daniel
    Almagor, Yaron
    Balkin, Jonathan
    Tauber, Rachel
    Merin, Ofer
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (04) : 448 - 454
  • [35] A Novel Transapical Transcatheter Aortic Valve System for Treatment of Aortic Stenosis: A Single-Center Early Experience
    Jin, Ping
    Guo, Hong
    Mao, Yu
    Zhai, Mengen
    Liu, Yang
    Yang, Jian
    CLINICAL MEDICINE INSIGHTS-CARDIOLOGY, 2025, 19
  • [36] Transfemoral transcatheter aortic valve replacement for pure native aortic regurgitation: one-year outcomes of a single-center study
    Zheng, Hua-Jie
    Cheng, Yong-Bo
    Yan, Chao-Jun
    Lin, De-Qing
    Yu, San-Jiu
    Li, Jun
    He, Ping
    Cheng, Wei
    BMC CARDIOVASCULAR DISORDERS, 2023, 23 (01)
  • [37] Trend and Outcomes of Direct Transcatheter Aortic Valve Replacement from a Single-Center Experience
    Bavry A.A.
    Aalaei-Andabili S.H.
    Park K.E.
    Choi C.Y.
    Manning III E.W.
    Stinson W.W.
    Cardiology and Therapy, 2018, 7 (2) : 191 - 196
  • [38] Early and Mid-Term Outcomes of Coronary Protection during Transcatheter Aortic Valve Replacement: A Single-Center Retrospective Analysis
    Zhou, Jiawei
    Li, Yuehuan
    Shen, Jinglun
    Wu, Kaisheng
    Wang, Jiangang
    Yu, Yi
    Zhang, Haibo
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (11)
  • [39] Pacemaker-Related Complications in Patients Undergoing Transcatheter Aortic Valve Implantation: A Single-Center Experience
    Lanzillo, Giuseppe
    Mangieri, Antonio
    Pagnesi, Matteo
    Montalto, Claudio
    Demir, Ozan M.
    Laricchia, Alessandra
    Curio, Jonathan
    Paglino, Gabriele
    Giannini, Francesco
    Colombo, Antonio
    Montorfano, Matteo
    Latib, Azeem
    JOURNAL OF INVASIVE CARDIOLOGY, 2020, 32 (12) : E362 - E369
  • [40] The outcomes of transcatheter aortic valve implantation with Edwards SAPIEN or CoreValve devices: Single-center experience in Turkey
    Gul, Mehmet
    Yildirim, Aydin
    Uslu, Nevzat
    Eksik, Abdurrahman
    Erol, Mustafa Kemal
    Uyarel, Huseyin
    Erturk, Mehmet
    Surgit, Ozgur
    Bakir, Ihsan
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 20 (03): : 434 - 441