Electrochemiluminescence Immunosensor Based on Platinum Electrode Modified with TiO2@ATO Nanocomposite for Sensitive Detection of AFB1

被引:10
|
作者
Cheng, Shuting [1 ,2 ,3 ]
Chu, Guanglei [1 ,2 ,3 ]
Liu, Zengning [1 ,2 ,3 ]
Guo, Yemin [1 ,2 ,3 ]
Sun, Xia [1 ,2 ,3 ]
机构
[1] Shandong Univ Technol, Sch Agr Engn & Food Sci, Zibo 255049, Peoples R China
[2] Shandong Prov Engn Res Ctr Vegetable Safety & Qua, Zibo 255049, Peoples R China
[3] Zibo City Key Lab Agr Prod Safety Traceabil, Zibo 255049, Peoples R China
基金
中国国家自然科学基金;
关键词
AFLATOXIN B-1; ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL APTASENSOR; MONOCLONAL-ANTIBODY; QUANTUM DOTS; LUMINOL; OXIDE; BIOSENSOR; NANOFLOWERS; CANCER;
D O I
10.1149/2.0741916jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel electrochemiluminescence (ECL) immunosensor was fabricated by using titanium dioxide (TiO2) and antimony tin oxide (ATO) nanocomposite as electrode modified material to detect aflatoxin B-1 (AFB(1)). Luminol with ECL characteristics was modified on the surface of a platinum electrode to prepare the luminescent electrode. The buffer solution contained hydrogen peroxide (H2O2) was used to monitor the ECL signals owing to the chemiluminescence properties of luminol-H2O2 in alkaline solution. TiO2 and ATO were doped with chitosan to form TiO2@ATO nanocomposite, which was modified on the electrode to enhance the ECL intensity by accelerating the electron transfer and provided more binding sites for aflatoxin B-1 antibody (Ab) and AFB(1). An ECL immunosensor was prepared for AFB(1) detection by modifying Ab and bovine serum albumin (BSA) successively. The specific combination of AFB(1) and Ab weakened the ECL intensity, thus the concentration of AFB(1) was determined according to the strength change of ECL signal. Under optimum conditions, the constructed immunosensor provided a wide linear range from 1.0 x 10(-2) to 1.0 x 10(3) ng mL(-1) with a detection limit of 0.03 ng mL(-1) (S/N = 3) and showed great specificity and high stability. Furthermore, the proposed immunosensor successfully demonstrated its applicability for detecting AFB(1) in peanut oil samples. (C) 2019 The Electrochemical Society.
引用
收藏
页码:B1727 / B1731
页数:5
相关论文
共 50 条
  • [31] Sensitive detection of H2O2 based on a MWCNTs/Ti3C2 nanocomposite-modified electrode
    Liu, Wei
    Li, Hongfang
    Li, Deming
    Liu, Xiaoting
    Liu, Lei
    Zhu, Zhiyong
    Hao, Haoyu
    Zeng, Qiongyao
    Sun, Yanhua
    ANALYTICAL METHODS, 2025,
  • [32] Degradation of AFB1 in edible oil by aptamer-modified TiO2 composite photocatalytic materials: Selective efficiency, degradation mechanism and toxicity
    Ku, Mengdan
    Li, Jiajun
    Zhang, Wenhao
    Sun, Shumin
    Zhang, Yaqi
    Xie, Yanli
    FOOD CHEMISTRY, 2025, 470
  • [33] An ultrasensitive label-free photoelectrochemical sensor based on Ag2O-sensitized WO3/TiO2 acicular composite for AFB1 detection
    Liu, Xin
    Fan, Dawei
    Duan, Shengquan
    Bao, Chunzhu
    Wang, Huan
    Wang, Xueying
    Sun, Xu
    Wei, Qin
    ANALYTICAL METHODS, 2019, 11 (30) : 3890 - 3897
  • [34] Label free electrochemiluminescence protocol for sensitive DNA detection with a tris(2,2'-bipyridyl)ruthenium(II) modified electrode based on nucleic acid oxidation
    Wei, Hui
    Du, Yan
    Kang, Jianzhen
    Wang, Erkang
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (07) : 1474 - 1479
  • [35] Sensitive detection of barium ion based on its enhancing effect on luminol electrochemiluminescence at cucurbit[7]uril-modified electrode
    Luo, Yuhua
    Yao, Haifeng
    Zhang, Yahui
    Dong, Yongping
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (05) : 1023 - 1032
  • [36] Sensitive detection of barium ion based on its enhancing effect on luminol electrochemiluminescence at cucurbit[7]uril-modified electrode
    Yuhua Luo
    Haifeng Yao
    Yahui Zhang
    Yongping Dong
    Journal of Applied Electrochemistry, 2023, 53 : 1023 - 1032
  • [37] Highly sensitive and selective detection of dopamine based on hollow gold nanoparticles-graphene nanocomposite modified electrode
    Zhu, Wencai
    Chen, Ting
    Ma, Xuemei
    Ma, Houyi
    Chen, Shenhao
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 321 - 326
  • [38] Sensitive Voltammetric Detection of Metol with a TiO2 Nanowire Modified Carbon Ionic Liquid Electrode
    Niu, Xueliang
    Yan, Lijun
    Li, Xiaobao
    Hu, Anhui
    Zheng, Caijuan
    Zhang, Yiliang
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1720 - 1729
  • [39] Highly sensitive electrochemiluminescence immunosensor based on ABEI/H2O2 system with PFO dots as enhancer for detection of kidney injury molecule-1
    Yang, Huiyun
    Wang, Haijun
    Xiong, Chengyi
    Chai, Yaqin
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2018, 116 : 16 - 22
  • [40] A fluorescent aptasensor based on nitrogen-doped carbon supported palladium and exonuclease III-assisted signal amplification for sensitive detection of AFB1
    Zhao, Luyang
    Suo, Zhiguang
    He, Baoshan
    Huang, Yawei
    Liu, Yong
    Wei, Min
    Jin, Huali
    ANALYTICA CHIMICA ACTA, 2022, 1226