Electrochemiluminescence Immunosensor Based on Platinum Electrode Modified with TiO2@ATO Nanocomposite for Sensitive Detection of AFB1

被引:10
|
作者
Cheng, Shuting [1 ,2 ,3 ]
Chu, Guanglei [1 ,2 ,3 ]
Liu, Zengning [1 ,2 ,3 ]
Guo, Yemin [1 ,2 ,3 ]
Sun, Xia [1 ,2 ,3 ]
机构
[1] Shandong Univ Technol, Sch Agr Engn & Food Sci, Zibo 255049, Peoples R China
[2] Shandong Prov Engn Res Ctr Vegetable Safety & Qua, Zibo 255049, Peoples R China
[3] Zibo City Key Lab Agr Prod Safety Traceabil, Zibo 255049, Peoples R China
基金
中国国家自然科学基金;
关键词
AFLATOXIN B-1; ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL APTASENSOR; MONOCLONAL-ANTIBODY; QUANTUM DOTS; LUMINOL; OXIDE; BIOSENSOR; NANOFLOWERS; CANCER;
D O I
10.1149/2.0741916jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel electrochemiluminescence (ECL) immunosensor was fabricated by using titanium dioxide (TiO2) and antimony tin oxide (ATO) nanocomposite as electrode modified material to detect aflatoxin B-1 (AFB(1)). Luminol with ECL characteristics was modified on the surface of a platinum electrode to prepare the luminescent electrode. The buffer solution contained hydrogen peroxide (H2O2) was used to monitor the ECL signals owing to the chemiluminescence properties of luminol-H2O2 in alkaline solution. TiO2 and ATO were doped with chitosan to form TiO2@ATO nanocomposite, which was modified on the electrode to enhance the ECL intensity by accelerating the electron transfer and provided more binding sites for aflatoxin B-1 antibody (Ab) and AFB(1). An ECL immunosensor was prepared for AFB(1) detection by modifying Ab and bovine serum albumin (BSA) successively. The specific combination of AFB(1) and Ab weakened the ECL intensity, thus the concentration of AFB(1) was determined according to the strength change of ECL signal. Under optimum conditions, the constructed immunosensor provided a wide linear range from 1.0 x 10(-2) to 1.0 x 10(3) ng mL(-1) with a detection limit of 0.03 ng mL(-1) (S/N = 3) and showed great specificity and high stability. Furthermore, the proposed immunosensor successfully demonstrated its applicability for detecting AFB(1) in peanut oil samples. (C) 2019 The Electrochemical Society.
引用
收藏
页码:B1727 / B1731
页数:5
相关论文
共 50 条
  • [21] Sensitive Voltammetric Detection of Metol with a TiO2 Nanowire Modified Carbon Ionic Liquid Electrode
    Niu, Xueliang
    Yan, Lijun
    Li, Xiaobao
    Hu, Anhui
    Zheng, Caijuan
    Zhang, Yiliang
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1720 - 1729
  • [22] A sensitive label-free electrochemical immunosensor for detection of cytokeratin 19 fragment antigen 21-1 based on 3D graphene with gold nanopaticle modified electrode
    Zeng, Yan
    Bao, Jing
    Zhao, Yanan
    Huo, Danqun
    Chen, Mei
    Yang, Mei
    Fa, Huanbao
    Hou, Changjun
    TALANTA, 2018, 178 : 122 - 128
  • [23] Development of Impedimetric Immunosensor for The Detection of Amyloid Beta (1-40) on maβa/ortho-Polyphenylenediamine Modified Platinum Micro Disk Electrode
    Norazreen, Z.
    Zainiharyati, M. Z.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 872 - 881
  • [24] Electrochemical Immunosensor for Carcinoembryonic Antigen Detection Based on Mo-Mn3O4/MWCNTs/Chits Nanocomposite Modified ITO Electrode
    Li, Wen-Ting
    Wang, Yu
    Deng, Fen-Fang
    Liu, Li-Li
    Nan, Hai-Jun
    Li, He
    NANO, 2015, 10 (08)
  • [25] Electrochemiluminescence immunosensor for highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on carbon quantum dot coated Au/SiO2 core-shell nanoparticles
    Zhang, Ting-Ting
    Zhao, Hui-Min
    Fan, Xin-Fei
    Chen, Shuo
    Quan, Xie
    TALANTA, 2015, 131 : 379 - 385
  • [26] Efficient double electrochemiluminescence quenching based label-free highly sensitive detection of haptoglobin on a novel nanocomposite modified carbon nanofibers interface
    Rizwan, Mohammad
    Keasberry, Natasha Ann
    Ahmed, Minhaz Uddin
    SENSING AND BIO-SENSING RESEARCH, 2019, 24
  • [27] Highly sensitive photoelectrochemical immunosensor based on anatase/rutile TiO2 and Bi2S3 for the zero-biased detection of PSA
    Monteiro, Thatyara Oliveira
    dos Santo, Clenilton Costa
    do Prado, Thiago Martimiano
    Damos, Flavio Santos
    Silva Luz, Rita de Cassia
    Fatibello-Filho, Orlando
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2020, 24 (08) : 1801 - 1809
  • [28] Microfluidic Immunosensor Platform for Sensitive Detection of Human Epidermal Growth Factor Receptor-2 Based on Enhanced Cathode Electrochemiluminescence of Bimetallic Nanoclusters
    Liu, Xuening
    Zhang, Xiaoyue
    Feng, Rui
    Ren, Xiang
    Wu, Dan
    Liu, Xuejing
    Liu, Lei
    Wei, Qin
    ANALYTICAL CHEMISTRY, 2024, 96 (21) : 8390 - 8398
  • [29] A sensitive electrochemiluminescence folic acid sensor based on a 3D graphene/CdSeTe/Ru(bpy)32+-doped silica nanocomposite modified electrode
    Li, Xiaoyu
    Tan, Xuecai
    Yan, Jun
    Hu, Qi
    Wu, Jiawen
    Zhang, Hui
    Chen, Xiao
    ELECTROCHIMICA ACTA, 2016, 187 : 433 - 441
  • [30] Target-Induced Electrochemical Sensor Based on Foldable Aptamer and MoS2@MWCNTs-PEI for Enhanced Detection of AFB1 in Peanuts
    Meng, Xiaoya
    Sang, Maosheng
    Guo, Qi
    Li, Zhongyu
    Zhou, Quanlong
    Sun, Xia
    Zhao, Wenping
    LANGMUIR, 2023, 39 (46) : 16422 - 16431