Efficacy of current and novel electromyographic normalization methods for lower limb high-speed muscle actions

被引:13
作者
Ball, Nick [1 ]
Scurr, Joanna C. [2 ]
机构
[1] Univ Canberra, Fac Hlth, Bruce, ACT 2617, Australia
[2] Univ Portsmouth, Dept Sport & Exercise Sci, Portsmouth, Hants, England
关键词
Normalization; surface electromyography; reliability; triceps surae; sprint; SURFACE ELECTROMYOGRAPHY; ISOMETRIC CONTRACTIONS; EMG NORMALIZATION; RELIABILITY; AMPLITUDE; ACTIVATION; COORDINATION; RECRUITMENT; KNEE; LEG;
D O I
10.1080/17461391.2010.536583
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The aim of this study was to assess the efficacy of electromyography (EMG) normalization methods for a high-speed 20-m sprint. Comparisons were based on intra-individual reliability and magnitude of normalized EMG signals from three repeat sessions separated by 1 day (between days) and 1 week (between weeks) from the initial test. Surface EMGs were recorded (n = 16) from the medial and lateral gastrocnemius and soleus during the normalization methods (isometric: maximum/submaximum/body weight; isotonic: maximum/sub-maximum/body weight; isokinetic: 1.05 rad . s(-1), 1.31 rad . s(-1), 1.83 rad . s(-1); squat jump). The EMG data from the 20-m sprint were normalized using each method and using the within-sprint peak EMG (sprint peak). Intra-individual reliability of the EMG was assessed using typical error of measurement as a percentage of intra-individual coefficient of variance (TEMCV%). Sprint peak normalization improved intra-individual reliability of EMG (soleus: <4.91(CV%); medial gastrocnemius: <6.2(CV%); lateral gastrocnemius: <7.1(CV%)) compared with un-normalized EMG (soleus: <13.3(CV%); medial gastrocnemius: <16.5(CV%); lateral gastrocnemius: <16.3(CV%)) both between days and between weeks. Squat jump normalization improved the soleus (<11.2(CV%)) and medial gastrocnemius (<15.7(CV%)) reliability between days and weeks and provided a representative measure of triceps surae muscle activation. The intra-individual reliability of the medial gastrocnemius EMG data was improved both between days and weeks when using isotonic normalization. Isometric and isokinetic normalization showed no improvement in intra-individual reliability either between days or weeks for any muscle. The method of normalization influenced the between-stride muscle interaction during the 20-m sprint. The results of this study suggest that peak normalization can be used to normalize high-speed muscle actions, while normalizing EMG to a squat jump may provide an alternative method to represent relative muscle activation.
引用
收藏
页码:447 / 456
页数:10
相关论文
共 43 条