Real-time Detection of Aortic Valve in Echocardiography using Convolutional Neural Networks

被引:13
作者
Nizar, Muhammad Hanif Ahmad [1 ]
Chan, Chow Khuen [1 ]
Khalil, Azira [2 ]
Yusof, Ahmad Khairuddin Mohamed [3 ]
Lai, Khin Wee [1 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Jalan Univ, Kuala Lumpur 50603, Malaysia
[2] Islamic Sci Univ Malaysia, Dept Appl Phys, Nilai 71800, Negeri Sembilan, Malaysia
[3] Natl Heart Inst, Kuala Lumpur 50400, Malaysia
关键词
Aortic valve; heart valve; echocardiography; cardiology; convolutional neural network; deep learning; DIAGNOSIS; DISEASE;
D O I
10.2174/1573405615666190114151255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Valvular heart disease is a serious disease leading to mortality and increasing medical care cost. The aortic valve is the most common valve affected by this disease. Doctors rely on echocardiogram for diagnosing and evaluating valvular heart disease. However, the images from echocardiogram are poor in comparison to Computerized Tomography and Magnetic Resonance Imaging scan. This study proposes the development of Convolutional Neural Networks (CNN) that can function optimally during a live echocardiographic examination for detection of the aortic valve. An automated detection system in an echocardiogram will improve the accuracy of medical diagnosis and can provide further medical analysis from the resulting detection. Methods: Two detection architectures, Single Shot Multibox Detector (SSD) and Faster Regional based Convolutional Neural Network (R-CNN) with various feature extractors were trained on echocardiography images from 33 patients. Thereafter, the models were tested on 10 echocardiography videos. Results: Faster R-CNN Inception v2 had shown the highest accuracy (98.6%) followed closely by SSD Mobilenet v2. In terms of speed, SSD Mobilenet v2 resulted in a loss of 46.81% in frames-per-second (fps) during real-time detection but managed to perform better than the other neural network models. Additionally, SSD Mobilenet v2 used the least amount of Graphic Processing Unit (GPU) but the Central Processing Unit (CPU) usage was relatively similar throughout all models. Conclusion: Our findings provide a foundation for implementing a convolutional detection system to echocardiography for medical purposes.
引用
收藏
页码:584 / 591
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1996, Presence
[2]  
Bradski G, 2000, DR DOBBS J SOFTWARE
[3]   An artifacts removal post-processing for epiphyseal region-of-interest (EROI) localization in automated bone age assessment (BAA) [J].
Chai, Hum Yan ;
Wee, Lai Khin ;
Swee, Tan Tian ;
Salleh, Sh-Hussain ;
Chea, Lim Yee .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[4]   The effects of frame rate and resolution on users playing first person shooter games [J].
Claypool, M ;
Claypool, K ;
Damaa, F .
MULTIMEDIA COMPUTING AND NETWORKING 2006, 2006, 6071
[5]  
Duruoz CI, 2003, DIGITAL VIDEO DECODI
[6]   The Pascal Visual Object Classes (VOC) Challenge [J].
Everingham, Mark ;
Van Gool, Luc ;
Williams, Christopher K. I. ;
Winn, John ;
Zisserman, Andrew .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2010, 88 (02) :303-338
[7]   Multiple LREK Active Contours for Knee Meniscus Ultrasound Image Segmentation [J].
Faisal, Amir ;
Ng, Siew-Cheok ;
Goh, Siew-Li ;
George, John ;
Supriyanto, Eko ;
Lai, Khin W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (10) :2162-2171
[8]   Registration of multiview real-time 3-D echocardiographic sequences [J].
Grau, Vicente ;
Becher, Harald ;
Noble, J. Alison .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (09) :1154-1165
[9]   Contrast enhancement of ultrasound imaging of the knee joint cartilage for early detection of knee osteoarthritis [J].
Hossain, Md Belayet ;
Lai, Khin Wee ;
Pingguan-Murphy, Belinda ;
Hum, Yan Chai ;
Salim, Maheza Irna Mohd ;
Liew, Yih Miin .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 13 :157-167
[10]  
Huang J, 2017, IEEE INT C INT ROBOT, P3296, DOI 10.1109/IROS.2017.8206166