A radiological evaluation of the morphometry and safety of S1, S2 and S2-ilium screws in the Asian population using three dimensional computed tomography scan: an analysis of 180 pelvis

被引:39
作者
Kwan, Mun Keong [1 ]
Jeffry, Amit [1 ]
Chan, Chris Yin Wei [1 ]
Saw, Lim Beng [1 ]
机构
[1] Univ Malaya, Dept Orthoped Surg, Fac Med, Kuala Lumpur 50603, Malaysia
关键词
Morphometry; Safety; S1; S2; S2-ilium screw; 1ST SACRAL VERTEBRA; FIXATION; PLACEMENT; ARTHRODESIS; PROJECTION; ADULTS; L5;
D O I
10.1007/s00276-011-0919-2
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Studies of sacral pedicle anatomy have been reported in the European population. However, the feasibility for the use of S1, S2 and S2-ilium screws has not been fully investigated in the Asian population. To assess feasibility, morphometric parameters and safety of S1, S2 and S2-ilium screw insertion in the Asian population. 180 three dimensional computed tomography (CT) scans of pelvis (90 males and 90 females) with contrast were analysed using Mimics(A (R)) version 13.1 (Materialise, Belgium) software. All parameters were measured using this programme. The safety medial trajectory of S1 pedicle screw was 11.8 +/- A 3.9 to 37.1 +/- A 4.5A degrees in males and 11.7 +/- A 3.1 to 35.9 +/- A 4.4A degrees in females. The screw length was from 35.0 +/- A 3.0 to 58.3 +/- A 3.1 mm in males and from 31.9 +/- A 2.6 to 53.1 +/- A 3.5 mm in females. Right S1 pedicle screws were safe as long as the anterior cortical penetration of quadrant 2, 3 and 4 were avoided. On the left, it was safe for the screws to exit at quadrant 1, 2 and 3. The lateral trajectory of S2 sacral alar screw was from 0 to 32.6 +/- A 3.3A degrees in males and from 0 to 33.6 +/- A 3.5A degrees in females. The screw length was from 23.9 +/- A 3.2 to 53.1 +/- A 4.1 mm in males and from 23.0 +/- A 2.5 to 53.2 +/- A 4.5 mm in females. For S2 screws, on the right side, the frequency of the internal iliac artery location was 7.2, 38.3, 47.2 and 1.7% for quadrants 1, 2, 3 and 4, whereas on the left side, the frequency was 7.8, 50.6, 33.9 and 2.2% for quadrants 1, 2, 3 and 4. For S2-ilium screws, the lateral trajectory was from 39.3 +/- A 3.1 to 50.4 +/- A 6.1A degrees in males and from 39.5 +/- A 3.1 to 50.2 +/- A 5.9A degrees in females. The screw lengths were from 85.3 +/- A 22.2 to 122.6 +/- A 11.4 mm and from 86.4 +/- A 22.7 to 122.2 +/- A 11.9 mm in males and females, respectively. The application of S1, S2 and S2-ilium screws are feasible. The amount of medial angulation and the ideal screw length in the Asian population must be borne in mind during insertion. Right S1 screws carry higher risk of injury to the internal iliac artery when the anterior cortical penetration occurs due to the course of the iliac vessels.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 20 条
  • [1] [Anonymous], NEUROANATOMY
  • [2] Low Profile Pelvic Fixation Anatomic Parameters for Sacral Alar-Iliac Fixation Versus Traditional Iliac Fixation
    Chang, Tai-Li
    Sponseller, Paul D.
    Kebaish, Khaled M.
    Fishman, Elliot K.
    [J]. SPINE, 2009, 34 (05) : 436 - 440
  • [3] ANATOMIC AND EXPERIMENTAL BASIS FOR THE INSERTION OF A SCREW AT THE 1ST SACRAL VERTEBRA
    DEPERETTI, F
    ARGENSON, C
    BOURGEON, A
    OMAR, F
    EUDE, P
    ABOULKER, C
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 1991, 13 (02) : 133 - 137
  • [4] Anatomic considerations of the second sacral vertebra and dorsal screw placement
    Ebraheim, NA
    Lu, J
    Yang, H
    Heck, BE
    Yeasting, RA
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 1997, 19 (06) : 353 - 357
  • [5] Long adult deformity fusions to L5 and the sacrum - A matched cohort analysis
    Edwards, CC
    Bridwell, KH
    Patel, A
    Rinella, AS
    Berra, A
    Lenke, LG
    [J]. SPINE, 2004, 29 (18) : 1996 - 2005
  • [6] Thoracolumbar deformity arthrodesis to L5 in adults: The fate of the L5-S1 disc
    Edwards, CC
    Bridwell, KH
    Patel, A
    Rinella, AS
    Kim, YJ
    Berra, A
    Della Rocca, GJ
    Lenke, LG
    [J]. SPINE, 2003, 28 (18) : 2122 - 2131
  • [7] SURGICAL ANATOMY OF THE SACRUM - A GUIDE FOR RATIONAL SCREW FIXATION
    ESSES, SI
    BOTSFORD, DJ
    HULER, RJ
    RAUSCHNING, W
    [J]. SPINE, 1991, 16 (06) : S283 - S288
  • [8] HARRINGTON PR, 1976, CLIN ORTHOP RELAT R, P157
  • [9] Sacropelvic Fixation Techniques and Complications
    Kebaish, Khaled M.
    [J]. SPINE, 2010, 35 (25) : 2245 - 2251
  • [10] Pseudarthrosis in adult spinal deformity following multisegmental instrumentation and arthrodesis
    Kim, YJ
    Bridwell, KH
    Lenke, LG
    Cho, KJ
    Enwards, CC
    Rinella, AS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (04) : 721 - 728