Airborne particulate matter (PM) filter analysis and modeling by total reflection X-ray fluorescence (TXRF) and X-ray standing wave (XSW)

被引:33
|
作者
Borgese, L. [1 ,2 ]
Salmistraro, M. [1 ,2 ]
Gianoncelli, A. [1 ,2 ]
Zacco, A. [1 ,2 ]
Lucchini, R. [3 ]
Zimmerman, N. [4 ]
Pisani, L. [5 ]
Siviero, G. [5 ]
Depero, L. E. [1 ,2 ]
Bontempi, E. [1 ,2 ]
机构
[1] Univ Brescia, INSTM, I-25123 Brescia, Italy
[2] Univ Brescia, Chem Technol Lab, I-25123 Brescia, Italy
[3] Univ Brescia, Inst Occupat Hlth, I-25123 Brescia, Italy
[4] Purdue Univ, Sch Hlth Sci, W Lafayette, IN 47907 USA
[5] GNR Srl, I-28010 Agrate Conturbia, NO, Italy
关键词
TXRF; XSW; Airbone particulate matter (PM) filter; Chemical analysis; DIFFRACTION;
D O I
10.1016/j.talanta.2011.11.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work is presented as an improvement of a recently introduced method for airborne particulate matter (PM) filter analysis [1]. X-ray standing wave (XSW) and total reflection X-ray fluorescence (TXRF) were performed with a new dedicated laboratory instrumentation. The main advantage of performing both XSW and TXRF, is the possibility to distinguish the nature of the sample: if it is a small droplet dry residue, a thin film like or a bulk sample. Another advantage is related to the possibility to select the angle of total reflection to make TXRF measurements. Finally, the possibility to switch the X-ray source allows to measure with more accuracy lighter and heavier elements (with a change in X-ray anode, for example from Mo to Cu). The aim of the present study is to lay the theoretical foundation of the new proposed method for airborne PM filters quantitative analysis improving the accuracy and efficiency of quantification by means of an external standard. The theoretical model presented and discussed demonstrated that airborne PM filters can be considered as thin layers. A set of reference samples is prepared in laboratory and used to obtain a calibration curve. Our results demonstrate that the proposed method for quantitative analysis of air PM filters is affordable and reliable without the necessity to digest filters to obtain quantitative chemical analysis, and that the use of XSW improve the accuracy of TXRF analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 104
页数:6
相关论文
共 50 条
  • [31] Thin film characterization by total reflection x-ray fluorescence
    Danel, Adrien
    Nolot, Emmanuel
    Veillerot, Marc
    Olivier, Segolene
    Decorps, Tifenn
    Calvo-Munoz, Maria-Luisa
    Hartmann, Jean-Michel
    Lhostis, Sandrine
    Kohno, Hiroshi
    Yamagami, Motoyuki
    Geoffroy, Charles
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (12) : 1365 - 1369
  • [32] Total reflection X-ray fluorescence analysis of pollen as an indicator for atmospheric pollution
    Pepponi, G
    Lazzeri, P
    Coghe, N
    Bersani, M
    Gottardini, E
    Cristofolini, F
    Clauser, G
    Torboli, A
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1205 - 1209
  • [33] Production of the ideal sample shape for Total Reflection X-ray Fluorescence analysis
    Horntrich, C.
    Kregsamer, P.
    Prost, J.
    Stadlbauer, F.
    Wobrauschek, P.
    Streli, C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 77 : 31 - 34
  • [34] Synchrotron radiation-induced total reflection X-ray fluorescence analysis
    Meirer, F.
    Singh, A.
    Pepponi, G.
    Streli, C.
    Homma, T.
    Pianetta, P.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (06) : 479 - 496
  • [35] Fundamental parameter model for quantification of total reflection X-ray fluorescence analysis
    Szaloki, I
    Radocz, G.
    Gerenyi, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 156 : 33 - 41
  • [36] Considerations on the ideal sample shape for Total Reflection X-ray Fluorescence Analysis
    Horntrich, C.
    Kregsamer, P.
    Wobrauschek, P.
    Streli, C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (11-12) : 815 - 821
  • [37] Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum
    Wobrauschek, P.
    Streli, C.
    Kregsamer, P.
    Meirer, F.
    Jokubonis, C.
    Markowicz, A.
    Wegrzynek, D.
    Chinea-Cano, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (12) : 1404 - 1407
  • [38] Total Reflection X-ray Spectrometry (TXRF) for Trace Elements Assessment in Edible Clams
    Margui, Eva
    Marques, Alexandra de Fatima
    Prisal, Maria de Lurdes
    Hidalgo, Manuela
    Queralt, Ignasi
    Carvalho, Maria Luisa
    APPLIED SPECTROSCOPY, 2014, 68 (11) : 1241 - 1246
  • [39] Low Z total reflection X-ray fluorescence analysis - challenges and answers
    Streli, C
    Kregsamer, P
    Wobrauschek, P
    Gatterbauer, H
    Pianetta, P
    Pahlke, S
    Fabry, L
    Palmetshofer, L
    Schmeling, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (10) : 1433 - 1441
  • [40] The assessment of a method for measurements and lead quantification in air particulate matter using total reflection X-ray fluorescence spectrometers
    Borgese, Laura
    Bilo, Fabjola
    Zacco, Annalisa
    Federici, Stefania
    Mutahi, Anne Wambui
    Bontempi, Elza
    Trzepla, Krystyna
    Hyslop, Nicole
    Yatkin, Sinan
    Wobrauschek, Peter
    Prost, Joseph
    Ingerle, Dieter
    Depero, Laura E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 167 (167)