Cardiac output measurement has become increasingly important in anaesthesia and critical care, particularly with the growing emphasis on perioperative medicine. Flow cannot be measured by any direct means and therefore models are employed to deduce useful information from other parameters. Numerous techniques are available, each with advantages and disadvantages in terms of invasiveness and validity. Often a balance is struck between invasiveness and validity of the measurements, with acceptance of trends monitoring in some cases, rather than absolute values of cardiac output.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 50 条
  • [41] Transpulmonary thermodilution cardiac output measurement is not affected by severe pulmonary oedema: a newborn animal study
    Nusmeier, A.
    Vrancken, S.
    de Boode, W. P.
    van der Hoeven, J. G.
    Lemson, J.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (02) : 286 - 292
  • [42] Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution
    Blissitt, KJ
    Young, LE
    Jones, RS
    Darke, PGG
    Utting, J
    EQUINE VETERINARY JOURNAL, 1997, 29 (01) : 18 - 25
  • [43] Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects
    Tomaske, Maren
    Knirsch, Walter
    Kretschmar, Oliver
    Balmer, Christian
    Woitzek, Katja
    Schmitz, Achim
    Bauersfeld, Urs
    Weiss, Markus
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2009, 26 (05) : 412 - 415
  • [44] Measurement of cardiac output from dynamic pulmonary circulation time CT
    Yee, Seonghwan
    Scalzetti, Ernest M.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [45] Evaluation of a noninvasive method for cardiac output measurement in critical care patients
    Murias, GE
    Villagrá, A
    Vatua, S
    Fernandez, MDM
    Solar, H
    Ochagavía, A
    Fernández, R
    Aguilar, JL
    Romero, PV
    Blanch, L
    INTENSIVE CARE MEDICINE, 2002, 28 (10) : 1470 - 1474
  • [46] Transpulmonary cardiac output measurement in a rat model of cardiac arrest and CPR: Impact of vascular access
    Kelm, Robert F.
    Wagenfuehrer, Juergen
    Schmidtmann, Irene
    Engelhard, Kristin
    Werner, Christian
    Noppens, Ruediger R.
    RESUSCITATION, 2010, 81 (02) : 248 - 254
  • [47] Comparison of two methods for cardiac output measurement in critically ill patients
    Saraceni, E.
    Rossi, S.
    Persona, P.
    Dan, M.
    Rizzi, S.
    Meroni, M.
    Ori, C.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (05) : 690 - 694
  • [48] Validation of MRI measurement of cardiac output in the dog: The effects of dobutamine and minoxidil
    Hockings, PD
    Busza, AL
    Byrne, J
    Patel, B
    Smart, SC
    Reid, DG
    Lloyd, HL
    White, A
    Pointing, K
    Farnfield, BA
    Criado-Gonzalez, A
    Whelan, GA
    Taylor, GL
    Birmingham, JM
    Slaughter, MR
    Osborne, JA
    Krebs-Brown, A
    Templeton, D
    TOXICOLOGY MECHANISMS AND METHODS, 2003, 13 (01) : 39 - 43
  • [49] Arterial thermodilution for the measurement of continuous cardiac output and intrathoracic blood volume
    Perel, A
    STATE-OF-THE-ART TECHNOLOGY IN ANESTHESIA AND INTENSIVE CARE, 1998, 1168 : 67 - 73
  • [50] Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
    Lemson, Joris
    de Boode, Willem P.
    Hopman, Jeroen C. W.
    Singh, Sandeep K.
    van der Hoeven, Johannes G.
    PEDIATRIC CRITICAL CARE MEDICINE, 2008, 9 (03) : 313 - 319