Cardiac output measurement

被引:1
|
作者
Kolb, Benjamin [1 ]
Kapoor, Vikas [2 ]
机构
[1] North Manchester Gen Hosp, Anaesthesia, Manchester, Lancs, England
[2] North Manchester Gen Hosp, Manchester, Lancs, England
关键词
Aortic Doppler; bioimpedance; cardiac output; indicator dilution; oesophageal Doppler; pulse contour analysis; pulse power analysis; pulse waveform analysis; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.1016/j.mpaic.2019.01.007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cardiac output measurement has become increasingly important in anaesthesia and critical care, particularly with the growing emphasis on perioperative medicine. Flow cannot be measured by any direct means and therefore models are employed to deduce useful information from other parameters. Numerous techniques are available, each with advantages and disadvantages in terms of invasiveness and validity. Often a balance is struck between invasiveness and validity of the measurements, with acceptance of trends monitoring in some cases, rather than absolute values of cardiac output.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 50 条
  • [31] Measurement of Cardiac Output in Children by Bioreactance
    Yolanda Ballestero
    Jesús López-Herce
    Javier Urbano
    Maria José Solana
    Marta Botrán
    Jose M. Bellón
    Angel Carrillo
    Pediatric Cardiology, 2011, 32 : 469 - 472
  • [32] Cardiac output measurement in pediatric anesthesia
    Skowno, Justin J.
    Broadhead, Michael
    PEDIATRIC ANESTHESIA, 2008, 18 (11) : 1019 - 1028
  • [33] Equipment review: New techniques for cardiac output measurement - oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis
    Berton, C
    Cholley, B
    CRITICAL CARE, 2002, 6 (03): : 216 - 221
  • [34] Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique
    Raval N.Y.
    Squara P.
    Cleman M.
    Yalamanchili K.
    Winklmaier M.
    Burkhoff D.
    Journal of Clinical Monitoring and Computing, 2008, 22 (2) : 113 - 119
  • [35] Noninvasive Assessment of Cardiac Output: Accuracy and Precision of the Closed-Circuit Acetylene Rebreathing Technique for Cardiac Output Measurement
    Hardin, E. Ashley
    Stoller, Douglas
    Lawley, Justin
    Howden, Erin J.
    Hieda, Michinari
    Pawelczyk, James
    Jarvis, Sara
    Prisk, Kim
    Sarma, Satyam
    Levine, Benjamin D.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2020, 9 (17):
  • [36] MEASUREMENT OF CARDIAC-OUTPUT - TRANSTRACHEAL DOPPLER VERSUS THERMODILUTION
    FROESE, N
    FRIESEN, R
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (07): : 931 - 934
  • [37] THE VALIDITY OF CARDIAC-OUTPUT MEASUREMENT BY THORACIC IMPEDANCE - A METAANALYSIS
    FULLER, HD
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1992, 15 (02): : 103 - 112
  • [38] Equipment review: New techniques for cardiac output measurement – oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis
    Christine Berton
    Bernard Cholley
    Critical Care, 6
  • [39] Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique
    Della Rocca, G
    Costa, MG
    Pompei, L
    Coccia, C
    Pietropaoli, P
    BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) : 350 - 356
  • [40] Analysis of the accuracy of continuous thermodilution cardiac output measurement - Comparison with intermittent thermodilution and Fick cardiac output measurement
    Jacquet, L
    Hanique, G
    Glorieux, D
    Matte, P
    Goenen, M
    INTENSIVE CARE MEDICINE, 1996, 22 (10) : 1125 - 1129