Cardiac output measurement

被引:1
|
作者
Kolb, Benjamin [1 ]
Kapoor, Vikas [2 ]
机构
[1] North Manchester Gen Hosp, Anaesthesia, Manchester, Lancs, England
[2] North Manchester Gen Hosp, Manchester, Lancs, England
关键词
Aortic Doppler; bioimpedance; cardiac output; indicator dilution; oesophageal Doppler; pulse contour analysis; pulse power analysis; pulse waveform analysis; thermodilution; THORACIC ELECTRICAL BIOIMPEDANCE;
D O I
10.1016/j.mpaic.2019.01.007
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cardiac output measurement has become increasingly important in anaesthesia and critical care, particularly with the growing emphasis on perioperative medicine. Flow cannot be measured by any direct means and therefore models are employed to deduce useful information from other parameters. Numerous techniques are available, each with advantages and disadvantages in terms of invasiveness and validity. Often a balance is struck between invasiveness and validity of the measurements, with acceptance of trends monitoring in some cases, rather than absolute values of cardiac output.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 50 条
  • [1] Cardiac output monitoring
    Betteridge, Nathan
    Armstrong, Fiona
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2022, 23 (02) : 101 - 110
  • [2] Cardiac output measurement
    Gilbert, Michael
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2016, 17 (02) : 95 - 101
  • [3] Cardiac output measurement
    Gilbert, Michael
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2013, 14 (02) : 63 - 67
  • [4] Cardiac output measurement
    Prabhu, Mahesh
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2007, 8 (02) : 66 - 69
  • [5] Cardiac output measurement
    Holmes, Thomas W. L.
    Williams, David J.
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2010, 11 (02) : 58 - 61
  • [6] Clinical validation of bioreactance for the measurement of cardiac output in pregnancy
    Ling, H. Z.
    Gallardo-Arozena, M.
    Company-Calabuig, A. M.
    Nicolaides, K. H.
    Kametas, N. A.
    ANAESTHESIA, 2020, 75 (10) : 1307 - 1313
  • [7] Lithium dilution cardiac output measurement: A comparison with thermodilution
    Linton, R
    Band, D
    OBrien, T
    Jonas, M
    Leach, R
    CRITICAL CARE MEDICINE, 1997, 25 (11) : 1796 - 1800
  • [8] Cardiac output measurement in children: comparison of the Ultrasound Cardiac Output Monitor with thermodilution cardiac output measurement
    Walter Knirsch
    Oliver Kretschmar
    Maren Tomaske
    Kathrina Stutz
    Nicole Nagdyman
    Christian Balmer
    Achim Schmitz
    Dominique Béttex
    Felix Berger
    Urs Bauersfeld
    Markus Weiss
    Intensive Care Medicine, 2008, 34 : 1060 - 1064
  • [9] Methods in pharmacology: measurement of cardiac output
    Geerts, Bart F.
    Aarts, Leon P.
    Jansen, Jos R.
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2011, 71 (03) : 316 - 330
  • [10] Measurement of Cardiac Output in Children by Bioreactance
    Ballestero, Yolanda
    Lopez-Herce, Jesus
    Urbano, Javier
    Jose Solana, Maria
    Botran, Marta
    Bellon, Jose M.
    Carrillo, Angel
    PEDIATRIC CARDIOLOGY, 2011, 32 (04) : 469 - 472