Passive sampling techniques for sensing freely dissolved hydrophobic organic chemicals in sediment porewater

被引:24
作者
Bao, Lian-Jun [1 ,2 ]
Zeng, Eddy Y. [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Guangdong, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Equilibrium sampling; Hydrophobic organic chemical; In-fiber standardization; Kinetic diffusion-controlled sampling; Low density polyethylene; Passive sampler; Sediment porewater; Solid-phase microextraction; Time-weighted average sampling; SOLID-PHASE MICROEXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; SEMIPERMEABLE-MEMBRANE DEVICES; PORE-WATER; POLYETHYLENE DEVICES; MONITOR POPS; SAMPLERS; BIOAVAILABILITY; POLLUTANTS; SPME;
D O I
10.1016/j.trac.2011.05.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With compiled and analyzed information about recent advances in passive sampling techniques for sediment porewater, we discuss common quantitation methods (equilibrium and kinetic diffusion-controlled sampling), effects of temperature and salinity on passive sampling, and benefits and drawbacks of currently available passive samplers based on the principles of solid-phase microextraction. The results show that the in-fiber standardization technique, which is kinetic diffusion-controlled, could shorten sampling time and obtain accurate results using isotopically-labeled reference compounds. Another quantitative method, time-weighted average sampling, may be viable for simultaneously measuring all analytes in sediment porewater, as it is more effective with respect to cost and time. In addition, the effects of temperature and salinity on passive sampling should be quantified in field applications. Currently available passive samplers (e.g., employing polymer-coated fibers and low-density polyethylene sheets) can sense hydrophobic organic chemicals (HOCs) in sediment porewater, but the small capacity and the inflexibility of polymer-coated fibers need to be further improved, while better physical protection of polyethylene devices, particularly when they are deployed under rough conditions, should be carefully considered. In conclusion, passive samplers for in-situ measurement of dissolved HOCs in sediment porewater should be combined with a suitable quantitative method and calibration for the effects of temperature and salinity. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1422 / 1428
页数:7
相关论文
共 40 条
[1]   Reinterpreting literature sorption data considering both absorption into organic carbon and adsorption onto black carbon [J].
Accardi-Dey, A ;
Gschwend, PM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (01) :99-106
[2]   Polyethylene devices: Passive samplers for measuring dissolved hydrophobic organic compounds in aquatic environments [J].
Adams, Rachel G. ;
Lohmann, Rainer ;
Fernandez, Loretta A. ;
Macfarlane, John K. ;
Gschwend, Philip M. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (04) :1317-1323
[3]  
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[4]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[5]  
Bao L.-J., 2011, UNPUB
[6]   Comment on "Global Aquatic Passive Sampling (AQUA-GAPS): Using Passive Samplers to Monitor POPs in the Waters of the World" [J].
Bao, Lian-Jun ;
Zeng, Eddy Y. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (12) :4385-4385
[7]   Temperature-dependent uptake rates of nonpolar organic compounds by semipermeable membrane devices and low-density polyethylene membranes [J].
Booij, K ;
Hofmans, HE ;
Fischer, CV ;
Van Weerlee, EM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (02) :361-366
[8]   Dissolved PCBs, PAHs, and HCB in pore waters and overlying waters of contaminated harbor sediments [J].
Booij, K ;
Hoedemaker, JR ;
Bakker, JF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (18) :4213-4220
[9]   Kinetics and the on-site application of standards in a solid-phase microextration fiber [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5807-5815
[10]   Field testing of equilibrium passive samplers to determine freely dissolved native polycyclic aromatic hydrocarbon concentrations [J].
Cornelissen, Gerard ;
Pettersen, Arne ;
Broman, Dag ;
Mayer, Philipp ;
Breedveld, Gijs D. .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2008, 27 (03) :499-508