Determining performance characteristics of an NGS-based HLA typing method for clinical applications

被引:75
作者
Duke, J. L. [1 ]
Lind, C. [1 ]
Mackiewicz, K. [1 ]
Ferriola, D. [1 ]
Papazoglou, A. [1 ]
Gasiewski, A. [1 ]
Heron, S. [1 ]
Huynh, A. [1 ]
McLaughlin, L. [1 ]
Rogers, M. [1 ]
Slavich, L. [1 ]
Walker, R. [1 ]
Monos, D. S. [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Dept Pathol & Lab Med, Immunogenet Lab, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Dept Pathol & Lab Med, Philadelphia, PA USA
关键词
human leukocyte antigen genotyping; MiSeq; next-generation sequencing; HIGH-RESOLUTION; HIGH-THROUGHPUT; LOCI; MISEQ;
D O I
10.1111/tan.12736
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
This study presents performance specifications of an in-house developed human leukocyte antigen (HLA) typing assay using next-generation sequencing (NGS) on the Illumina MiSeq platform. A total of 253 samples, previously characterized for HLA-A, -B, -C, -DRB1 and -DQB1 were included in this study, which were typed at high-resolution using a combination of Sanger sequencing, sequence-specific primer (SSP) and sequence-specific oligonucleotide probe (SSOP) technologies and recorded at the two-field level. Samples were selected with alleles that cover a high percentage of HLA specificities in each of five different race/ethnic groups: European, African-American, Asian Pacific Islander, Hispanic and Native American. Sequencing data were analyzed by two software programs, Omixon's TARGET and GenDx's NGSENGINE. A number of metrics including allele balance, sensitivity, specificity, precision, accuracy and remaining ambiguity were assessed. Data analyzed by the two software systems are shown independently. The majority of alleles were identical in the exonic sequences (third field) with both programs for HLA-A, -B, -C and -DQB1 in 97.7% of allele determinations. Among the remaining discrepant genotype calls at least one of the analysis programs agreed with the reference typing. Upon additional manual analysis 100% of the 2530 alleles were concordant with the reference HLA genotypes; the remaining ambiguities did not exceed 0.8%. The results demonstrate the feasibility and significant benefit of HLA typing by NGS as this technology is highly accurate, eliminates virtually all ambiguities, provides complete sequencing information for the length of the HLA gene and forms the basis for utilizing a single methodology for HLA typing in the immunogenetics labs.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 18 条
[1]   Ambiguous allele combinations in HLA class I and class II sequence-based typing: When precise nucleotide sequencing leads to imprecise allele identification [J].
Adams S.D. ;
Barracchini K.C. ;
Chen D. ;
Robbins F. ;
Wang L. ;
Larsen P. ;
Luhm R. ;
Stroncek D.F. .
Journal of Translational Medicine, 2 (1)
[2]   High-resolution, high-throughput HLA genotyping by next-generation sequencing [J].
Bentley, G. ;
Higuchi, R. ;
Hoglund, B. ;
Goodridge, D. ;
Sayer, D. ;
Trachtenberg, E. A. ;
Erlich, H. A. .
TISSUE ANTIGENS, 2009, 74 (05) :393-403
[3]   Rapid, scalable and highly automated HLA genotyping using next-generation sequencing: a transition from research to diagnostics [J].
Danzer, Martin ;
Niklas, Norbert ;
Stabentheiner, Stephanie ;
Hofer, Katja ;
Proell, Johannes ;
Stueckler, Christina ;
Raml, Edeltraud ;
Polin, Helene ;
Gabriel, Christian .
BMC GENOMICS, 2013, 14
[4]   16th IHIW: Review of HLA typing by NGS [J].
De Santis, D. ;
Dinauer, D. ;
Duke, J. ;
Erlich, H. A. ;
Holcomb, C. L. ;
Lind, C. ;
Mackiewicz, K. ;
Monos, D. ;
Moudgil, A. ;
Norman, P. ;
Parham, P. ;
Sasson, A. ;
Allcock, R. J. N. .
INTERNATIONAL JOURNAL OF IMMUNOGENETICS, 2013, 40 (01) :72-76
[5]   Towards allele-level human leucocyte antigens genotyping - assessing two next-generation sequencing platforms: Ion Torrent Personal Genome Machine and Illumina MiSeq [J].
Duke, J. L. ;
Lind, C. ;
Mackiewicz, K. ;
Ferriola, D. ;
Papazoglou, A. ;
Derbeneva, O. ;
Wallace, D. ;
Monos, D. S. .
INTERNATIONAL JOURNAL OF IMMUNOGENETICS, 2015, 42 (05) :346-358
[6]   Next-generation sequencing for HLA typing of class I loci [J].
Erlich, Rachel L. ;
Jia, Xiaoming ;
Anderson, Scott ;
Banks, Eric ;
Gao, Xiaojiang ;
Carrington, Mary ;
Gupta, Namrata ;
DePristo, Mark A. ;
Henn, Matthew R. ;
Lennon, Niall J. ;
de Bakker, Paul I. W. .
BMC GENOMICS, 2011, 12
[7]   Rapid high-throughput human leukocyte antigen typing by massively parallel pyrosequencing for high-resolution allele identification [J].
Gabriel, Christian ;
Danzer, Martin ;
Hackl, Christa ;
Kopal, Guido ;
Hufnagl, Peter ;
Hofer, Katja ;
Polin, Helene ;
Stabentheiner, Stephanie ;
Proell, Johannes .
HUMAN IMMUNOLOGY, 2009, 70 (11) :960-964
[8]   Six-locus high resolution HLA haplotype frequencies derived from mixed-resolution DNA typing for the entire US donor registry [J].
Gragert, Loren ;
Madbouly, Abeer ;
Freeman, John ;
Maiers, Martin .
HUMAN IMMUNOLOGY, 2013, 74 (10) :1313-1320
[9]   A multi-site study using high-resolution HLA genotyping by next generation sequencing [J].
Holcomb, C. L. ;
Hoeglund, B. ;
Anderson, M. W. ;
Blake, L. A. ;
Boehme, I. ;
Egholm, M. ;
Ferriola, D. ;
Gabriel, C. ;
Gelber, S. E. ;
Goodridge, D. ;
Hawbecker, S. ;
Klein, R. ;
Ladner, M. ;
Lind, C. ;
Monos, D. ;
Pando, M. J. ;
Proell, J. ;
Sayer, D. C. ;
Schmitz-Agheguian, G. ;
Simen, B. B. ;
Thiele, B. ;
Trachtenberg, E. A. ;
Tyan, D. B. ;
Wassmuth, R. ;
White, S. ;
Erlich, H. A. .
TISSUE ANTIGENS, 2011, 77 (03) :206-217
[10]   Phase-defined complete sequencing of the HLA genes by next-generation sequencing [J].
Hosomichi, Kazuyoshi ;
Jinam, Timothy A. ;
Mitsunaga, Shigeki ;
Nakaoka, Hirofumi ;
Inoue, Ituro .
BMC GENOMICS, 2013, 14