A techno-commercial review on grid connected photovoltaic system

被引:35
作者
Chatterjee, Shantanu [1 ]
Kumar, Prashant [1 ]
Chatterjee, Saibal [2 ]
机构
[1] NIT, Dept Elect Engn, Yupia, Arunachal Prade, India
[2] NERIST, Dept Elect Engn, Nirjuli, Arunachal Prade, India
关键词
Anti-islanding; Filter; Maximum power point tracking (MPPT); Neutral point clamp inverter(NPC); Phase locked loop(PLL); Photovoltaic(PV); Pulse width modulation(PWM); Synchronous reference frame(SRF); POWER-POINT TRACKING; MAXIMUM-POWER; ISLANDING-DETECTION; MPPT ALGORITHM; PERFORMANCE EVALUATION; CURRENT CONTROLLER; CONTROL STRATEGY; SOLAR-ENERGY; LOCKED LOOP; INVERTER;
D O I
10.1016/j.rser.2017.06.045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Owing to rapid depletion of fossil fuels and environmental hazard, different non-conventional sources of energy like wind, geothermal, nuclear, photovoltaic etc, have been taken into consideration for power generation. Environmental familiarness, reduced installation cost, improved power quality, abundant availability of source makes photovoltaic based distributed generation as one of the most popular alternative source of energy production. Improvement in power electronics technology makes synchronization of PV system with grid more viable. Power output from the PV module changes continuously with time depending upon the climatic condition. In order to get maximum output from the PV system different types of MPPT algorithm present in literature are studied and improvement proposed are described in this paper. Furthermore, different types of inverter topologies along with different grid synchronization technique and PWM topologies used to connect the PV system with the 3-phase AC grid are presented. In order to minimize the harmonic content of the inverter output, different types of filters used are presented in the proceeding section. Nextly different commonly used advanced islanding detection techniques for the safety purpose of PV based distribution generation system have been addressed and based on advantages and limitation of anti-islanding techniques, a comparison table has been presented. Afterward based on parameters like input, output voltage & current, MPP range, used standards etc, a comparison table between different commercially available grid tied PV inverters are presented in this paper. Finally, drawbacks of the prevailing grid connected PV system have been discussed.
引用
收藏
页码:2371 / 2397
页数:27
相关论文
共 139 条
[31]  
Chandhaket S, 2001, IEEE POWER ELECTRON, P589, DOI 10.1109/PESC.2001.954179
[32]  
Chandran-Wadia L, 2002, PROCEEDINGS OF THE ICCC 2002: 15TH INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION, VOLS 1 AND 2, P36
[33]   An Improved MPPT Controller for Photovoltaic System Under Partial Shading Condition [J].
Chen, Kai ;
Tian, Shulin ;
Cheng, Yuhua ;
Bai, Libing .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (03) :978-985
[34]   Unified Control of Photovoltaic Grid-connection and Power Quality managements [J].
Chen, Xiaogao ;
Fu, Qing ;
Yu, Shijie ;
Zhou, Longhua .
2008 WORKSHOP ON POWER ELECTRONICS AND INTELLIGENT TRANSPORTATION SYSTEM, PROCEEDINGS, 2008, :360-365
[35]   Accurate and Less-Disturbing Active Antiislanding Method Based on PLL for Grid-Connected Converters [J].
Ciobotaru, Mihai ;
Agelidis, Vassilios G. ;
Teodorescu, Remus ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1576-1584
[36]   Improving the Lifetime of Non-Penetrable Barrier Coverage in Sensor Networks [J].
Cobb, Jorge A. .
2015 IEEE 35TH INTERNATIONAL CONFERENCE ON DISTRIBUTED COMPUTING SYSTEMS WORKSHOPS (ICDCSW), 2015, :1-7
[37]   Review of multilevel voltage source inverter topologies and control schemes [J].
Colak, Ilhami ;
Kabalci, Ersan ;
Bayindir, Ramazan .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) :1114-1128
[38]   New hysteresis current controller for single-phase full-bridge inverters [J].
Dahono, P. A. .
IET POWER ELECTRONICS, 2009, 2 (05) :585-594
[39]   Space-Vector Versus Nearest-Level Pulse Width Modulation for Multilevel Converters [J].
Deng, Yi ;
Harley, Ronald G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (06) :2962-2974
[40]   A modified active frequency drift method for anti-islanding of grid-connected PV systems [J].
Ding Qiang ;
Xu Zheng ;
Li You-Chun .
2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, :2730-2733