Erroneous production of PAPP-A kits: the impact of a downward shift in PAPP-A concentration on the test performance of first-trimester combined screening for Down syndrome

被引:1
作者
van Heesch, P. N. A. C. M. [1 ]
de Rijke, Y. B. [2 ,3 ]
Laudy, J. A. M. [3 ]
Wildschut, H. I. J. [1 ]
机构
[1] Univ Med Ctr, Div Obstet & Prenatal Med, Dept Obstet & Gynecol, Rotterdam, Netherlands
[2] Univ Med Ctr, Erasmus MC, Dept Clin Chem, Rotterdam, Netherlands
[3] Star Med Diagnost Ctr, Prenatal Ctr Rijnmond, Rotterdam, Netherlands
关键词
beta-hCG; biochemical screening; Down syndrome; first-trimester screening; NT; PAPP-A; PLASMA PROTEIN-A; GENETIC AMNIOCENTESIS; CHROMOSOMAL DEFECTS; RISK; NETHERLANDS; MULTICENTER;
D O I
10.1002/pd.2775
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Objective To evaluate a 20% downward shift in the pregnancy-associated plasma protein A (PAPP-A) concentration on the test performance of first-trimester combined screening (FTS) for Down syndrome (DS) following a flaw in the production of PAPP-A kits on FTS for DS. Methods A retrospective re-evaluation of PAPP-A in stored sera. Inclusion criteria were a maternal weight-corrected PAPP-A multiple of the median value >= 0.9 and a biochemical risk of DS <= 1 : 200 at the time of testing. Results Of the 3100 women, 473 (15%) fulfilled the inclusion criteria. After combining the biochemical risk based on the incorrect PAPP-A values with nuchal translucency findings, an increased risk for DS was initially found in 107 women [false positive rate (FPR): 3.1]. Eighty-two (77%) of the 107 women opted for invasive testing. Following re-analysis of PAPP-A, the biochemical risk and the combined risk were statistically significantly different from the initial risk estimates (p < 0.001.). We noticed that 25 women (30%) had invasive testing, while this was unjustified given the re-analysed PAPP-A. Conclusion Erroneous PAPP-A kits resulted in an increase in the FPR by 1.2%. There were no reports of iatrogenic miscarriage. The occurrence of this problem reaffirms the importance of continuous monitoring of quality in FTS. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:821 / 826
页数:6
相关论文
共 31 条
  • [31] Prenatal diagnosis and molecular cytogenetic characterization of a de novo deletion of 4q34.1/qter associated with low PAPP-A and low PlGF in the first-trimester maternal serum screening, congenital heart defect on fetal ultrasound and a false negative non-invasive prenatal testing (NIPT) result
    Chen, Chih-Ping
    Chen, Shin-Wen
    Wang, Liang-Kai
    Chern, Schu-Rern
    Wu, Peih-Shan
    Wu, Fang-Tzu
    Chen, Li-Feng
    Wang, Wayseen
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2022, 61 (06): : 1039 - 1043