COBRA-STAR, a five frame point-projection x-ray imaging system for 1 MA scale wire-array Z pinches

被引:32
作者
Douglass, J. D. [1 ]
Hammer, D. A. [1 ]
机构
[1] Cornell Univ, Plasma Studies Lab, Ithaca, NY 14853 USA
关键词
D O I
10.1063/1.2884707
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new imaging system for 1 MA scale wire-array Z-pinch experiments that produces up to five high-resolution x-ray images per experimental pulse has been developed. Calibrated areal density measurements of the Z-pinch plasma can be obtained from each pulse. The system substitutes five molybdenum (Mo) X pinches for the normal copper return-current conductors to provide point sources of x-rays for point-projection radiography. Each backlighting X pinch consists of four Mo wires, the x-ray burst timing of which was controlled by varying the wire diameter (mass) from 10.2 to 30 mu m in the five X pinches. Typical images have a 16 x 8 mm(2) field of view at the wire array and a magnification of about 6.5:1 on the x-ray-sensitive film. Titanium (Ti) filters in front of the films transmit continuum radiation in the spectral range of 3-5 keV. Inclusion on the Ti of a step wedge having known thickness increments of the same material as the wires enables the calibrated areal density measurements to be made of the exploding wire plasmas. Here, we used tungsten (W) step wedges with step thicknesses ranging from 0.015 to 1.1 mu m to obtain accurate (+/- 10%) areal density measurements of W plasmas from the spatial profile of film exposure. When imaging arrays that produce intense radiation pulses, a plastic monofilament "quencher" is placed on axis to avoid film saturation. Images have subnanosecond temporal resolution and about 7 mu m spatial resolution. (C) 2008 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 17 条
[11]   High energy density Z-pinch plasma conditions with picosecond time resolution -: art. no. 035003 [J].
Pikuz, SA ;
Sinars, DB ;
Shelkovenko, TA ;
Chandler, KM ;
Hammer, DA ;
Ivanenkov, GV ;
Stepniewski, W ;
Skobelev, IY .
PHYSICAL REVIEW LETTERS, 2002, 89 (03) :350031-350034
[12]   Studies of plasma formation from exploding wires and multiwire arrays using x-ray backlighting [J].
Shelkovenko, TA ;
Pikuz, SA ;
Mingaleev, AR ;
Hammer, DA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :667-670
[13]   Multiwire X-pinches at 1-MA current on the COBRA pulsed-power generator [J].
Shelkovenko, Tatiana A. ;
Pikuz, Sergey A. ;
Douglass, Jonathan D. ;
McBride, Ryan D. ;
Greenly, John B. ;
Hammer, David A. .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (05) :2336-2341
[14]  
SHELLASS J, 2005, OJPUB IEEE PULSED PO, P273
[15]   Exploding aluminum wire expansion rate with 1-4.5 kA per wire [J].
Sinars, DB ;
Shelkovenko, TA ;
Pikuz, SA ;
Greenly, JB ;
Hammer, DA .
PHYSICS OF PLASMAS, 2000, 7 (05) :1555-1563
[16]   Determination of the size and structure of an X-pinch x-ray source from the diffraction pattern produced by microfabricated slits [J].
Song, BM ;
Pikuz, SA ;
Shelkovenko, TA ;
Hammer, DA .
APPLIED OPTICS, 2005, 44 (12) :2349-2358
[17]   Steady-state radiation ablation in the wire-array Z pinch [J].
Yu, Edmund P. ;
Oliver, B. V. ;
Sinars, D. B. ;
Mehlhorn, T. A. ;
Cuneo, M. E. ;
Sasorov, P. V. ;
Haines, M. G. ;
Lebedev, S. V. .
PHYSICS OF PLASMAS, 2007, 14 (02)