Determination of ammonium in wastewaters by capillary electrophoresis on a column-coupling chip with conductivity detection

被引:14
作者
Luc, Milan [1 ]
Kruk, Pavol [1 ]
Masar, Marian [1 ]
机构
[1] Comenius Univ, Dept Analyt Chem, Fac Nat Sci, SK-84215 Bratislava, Slovakia
关键词
Ammonium; Chip electrophoresis; Conductivity detection; ITP sample pre-treatment; Wastewater; TOTAL ANALYSIS SYSTEMS; INDIRECT-UV DETECTION; ALKALINE-EARTH METAL; ZONE-ELECTROPHORESIS; CONCENTRATION RATIOS; ION CHROMATOGRAPHY; INORGANIC ANIONS; CATIONS; SEPARATION; ISOTACHOPHORESIS;
D O I
10.1002/jssc.201100201
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analytical potentialities of a chip-based CE in determination of ammonium in wastewaters were investigated. CZE with the electric field and/or ITP sample stacking was performed on a column-coupling (CC) chip with integrated conductivity detectors. Acetate background electrolytes (pH similar to 3) including 18-crown-6-ether (18-crown-6) and tartaric acid were developed to reach rapid (in 7-8 min) CZE and ITP-CZE resolutions of ammonium from other cations (sodium, potassium, calcium and magnesium) present in wastewater samples. Under preferred working conditions (suppressed hydrodynamic flow (HDF) and EOF on the column-coupling chip), both the employed methods did provide very good repeatabilities of the migration (RSD of 0.2-0.8% for the migration time) and quantitative (RSD of 0.3-4.9% for the peak area) parameters in the model and wastewater samples. Using a 900-nL sample injection volume, LOD for ammonium were obtained at 20 and 40 mu g/L concentrations in CZE and ITP-CZE separations, respectively. Very good agreements of the CZE and ITP-CZE determinations of ammonium in six untreated wastewater samples (only filtration and dilution) with the results obtained by a reference spectrometric method indicate a very good accuracy of both the CE methods presented.
引用
收藏
页码:1561 / 1567
页数:7
相关论文
共 37 条
  • [1] Sustainable nitrogen elimination biotechnologies: A review
    Ahn, Young-Ho
    [J]. PROCESS BIOCHEMISTRY, 2006, 41 (08) : 1709 - 1721
  • [2] [Anonymous], 1998, 149111 ISO
  • [3] [Anonymous], 2005, ISO 11732:2005-Water Quality-Determination of Ammonium Nitrogen-Method by Flow Analysis (CFA and FIA) and Spectrometric Detection
  • [4] [Anonymous], 1984, ISO 7150-1
  • [5] Latest Developments in Micro Total Analysis Systems
    Arora, Arun
    Simone, Giuseppina
    Salieb-Beugelaar, Georgette B.
    Kim, Jung Tae
    Manz, Andreas
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (12) : 4830 - 4847
  • [6] Miniaturised isotachophoresis analysis
    Chen, L
    Prest, JE
    Fielden, PR
    Goddard, NJ
    Manz, A
    Day, PJR
    [J]. LAB ON A CHIP, 2006, 6 (04) : 474 - 487
  • [7] Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis
    Felhofer, Jessica L.
    Blanes, Lucas
    Garcia, Carlos D.
    [J]. ELECTROPHORESIS, 2010, 31 (15) : 2469 - 2486
  • [8] CLARIFICATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY
    FOLEY, JP
    DORSEY, JG
    [J]. CHROMATOGRAPHIA, 1984, 18 (09) : 503 - 511
  • [9] DETERMINATION OF AMMONIUM ION IN SEA-WATER BY CAPILLARY ISOTACHOPHORESIS
    FUKUSHI, K
    HIIRO, K
    [J]. TALANTA, 1988, 35 (10) : 799 - 802
  • [10] Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection
    Fukushi, K
    Ito, H
    Kimura, K
    Yokota, K
    Saito, K
    Chayama, K
    Takeda, S
    Wakida, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1106 (1-2) : 61 - 66