A near-infrared spectroscopy method to determine aminoglycosides in pharmaceutical formulations

被引:16
作者
Sarraguca, Mafalda Cruz [1 ]
Soares, Sandra Oliveira [1 ]
Lopes, Joao Almeida [1 ]
机构
[1] Univ Porto, REQUIMTE, Dept Quim, Fac Farm, P-4090030 Oporto, Portugal
关键词
Aminoglycosides; Neomycin sulphate; Near-infrared spectroscopy; Partial least squares regression; Pharmaceutical industry; LIQUID-CHROMATOGRAPHIC METHOD; TANDEM MASS-SPECTROMETRY; NEOMYCIN SULFATE; PERFORMANCE; ANTIBIOTICS; PHASE; DERIVATIZATION; CHEMOMETRICS; QUANTITATION; GENTAMICIN;
D O I
10.1016/j.vibspec.2011.02.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical determination of aminoglycosides in pharmaceutical formulations is very difficult due to the lack of chromophores or fluorophores. Several analytical methods have been developed along the years mainly based on derivatization reactions. The European Pharmacopeia (EP) and the United States Pharmacopeia (USP) describe a microbiological assay to the quantification of aminoglycosides. Near infrared spectroscopy (NIRS) can be used alternatively to analyse aminoglycosides without the need of derivatization reactions or other type of sample processing. A new NIRS based method was developed for the analysis of the aminoglycoside antibiotic neomycin. The method was developed with samples based on a commercial formulation containing neomycin sulphate and three excipients: lactose, talc and magnesium stearate. Synthetic and doped samples were manufactured for this purpose. Three lots of a commercial solid formulation were also used to assess the validity of the method to quantify neomycin sulphate in the industrial pharmaceutical product. The method proposes measurements in reflectance mode using a Fourier-transform near infrared (FT-NIR) spectrometer. Partial least squares regression was the multivariate method adopted to calibrate the NIR spectra with the neomycin sulphate mass fraction. The concentration of neomycin sulphate present in the commercial samples was confirmed by H PLC with pre-column derivatization with phenylisocyanate. Results show that neomycin sulphate was determined successfully in the commercial samples using the method calibrated with the doped samples (mass fraction error of 6.6%). Moreover, the synthetic samples were found to be unqualified to develop the method, producing a biased calibration. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 53 条
[1]   Modified determination of dihydrostreptomycin in kidney, muscle and milk by HPLC [J].
Abbasi, H ;
Hellenäs, KE .
ANALYST, 1998, 123 (12) :2725-2727
[2]   Liquid chromatographic analysis of a formulation containing polymyxin, gramicidin and neomycin [J].
Adams, E ;
Schepers, R ;
Gathu, LW ;
Kibaya, R ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (04) :505-511
[3]   Determination of neomycin sulfate by liquid chromatography with pulsed electrochemical detection [J].
Adams, E ;
Schepers, R ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (02) :233-240
[4]   Ion-association method for the colorimetric determination of neomycin sulphate in pure and dosage forms [J].
Amin, AS ;
Issa, YM .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2003, 59 (04) :663-670
[5]  
[Anonymous], 2005, EUR PHARM 5 0
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF NEOMYCIN IN PETROLATUM-BASED OINTMENTS AND IN VETERINARY FORMULATIONS [J].
BINNS, RB ;
TSUJI, K .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (01) :69-72
[7]   Simultaneous quantitation of five active principles in a pharmaceutical preparation:: Development and validation of a near infrared spectroscopic method [J].
Blanco, M ;
Alcalá, M .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 27 (2-3) :280-286
[8]   Near-infrared spectroscopy in the pharmaceutical industry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
de la Pezuela, C .
ANALYST, 1998, 123 (08) :135R-150R
[9]   Influence of the procedure used to prepare the calibration sample set on the performance of near infrared spectroscopy in quantitative pharmaceutical analyses [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pou, N .
ANALYST, 2001, 126 (07) :1129-1134
[10]   An expeditious method for determining particle size distribution by near infrared spectroscopy: Comparison of PLS2 and ANN models [J].
Blanco, Marcelo ;
Peguero, Anna .
TALANTA, 2008, 77 (02) :647-651