Experimental investigation on the thermal performance of a vertical greening system with green roof in wet and cold climates during winter

被引:56
|
作者
Xing, Qingwei [1 ]
Hao, Xiaoli [1 ]
Lin, Yaolin [2 ]
Tan, Hang [1 ]
Yang, Ke [1 ]
机构
[1] Hunan Univ Sci & Technol, Coll Civil Engn, Xiangtan 411201, Hunan, Peoples R China
[2] Wuhan Univ Technol, Sch Civil Engn & Architecture, Wuhan 430070, Hubei, Peoples R China
关键词
Vertical greening system; Energy saving; Thermal performance; Indoor environment; URBAN HEAT-ISLAND; RESIDENTIAL BUILDINGS; ENERGY PERFORMANCE; WALLS; SURFACE; IMPACT; MITIGATION; VEGETATION; SAVINGS; FACADE;
D O I
10.1016/j.enbuild.2018.10.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, a novel vertical greening system has begun to spread worldwide. This system can provide several environmental benefits, such as alleviating urban heat island effects, increasing the number of green sceneries, improving atmospheric quality, relieving urban drainage pressures, and improving building energy efficiency. To evaluate the effect of a vertical greening system on indoor climate and the energy consumption of buildings under wet and cold climatic conditions during winter, contrastive experiments were performed in this study. Two experimental rooms of equal size with the same wall structures were set up in Hunan Province, China. One room had a vertical greening system, whereas the other room did not have one and was used as the reference room. Two types of experimental conditions, that is, with and without heating, were investigated. The experimental data were collected from December 2017, to January 2018. Results showed that without heating, the indoor air temperature swing of the room with vertical greening was significantly suppressed, in comparison with that of the reference room. The indoor air temperature of the room with vertical greening was 1-3 degrees C higher than that of the reference room at night. Meanwhile, the air layer temperature was 1-2 degrees C higher than that of the outdoor air throughout the day. Under heating conditions, the average heat flux through the walls of the reference room was 3.1 W/m(2) larger than that of the room with vertical greening. The measured electric energy consumption of the reference room was 1.22 times that of the vertical green room. An energy saving rate of 18% was achieved during the heating experiment owing to the extra thermal insulation provided by the vertical greening system. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 117
页数:13
相关论文
共 50 条
  • [41] Experimental and computational investigation of the thermal performance of a vertical tube evaporative condenser
    Wei, Junqing
    Liu, Jinpingi
    Xu, Xiongwen
    Ruan, Jiangao
    Li, Guoli
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [42] EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF WET COOLING TOWER WITH SPLASH FILLS PACKING
    Ahmed, Shaymaa A.
    Aljaberi, Forat Yasir
    Makki, Hasan F.
    THERMAL SCIENCE, 2022, 26 (02): : 1603 - 1613
  • [43] Dynamic thermal performance of inclined double-skin roof: Modeling and experimental investigation
    Zingre, Kishor T.
    Yang, En-Hua
    Wan, Man Pun
    ENERGY, 2017, 133 : 900 - 912
  • [44] Understanding the hydrological performance of green and grey roofs during winter in cold climate regions
    Maurin, Noelie
    Abdalla, Elhadi H. M.
    Muthanna, Tone Merete
    Sivertsen, Edvard
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 945
  • [45] EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF A MANIFOLD HIERARCHICAL MICROCHANNEL COLD PLATE
    Dede, Ercan M.
    PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 59 - 67
  • [46] Influence of plant and soil layer on energy balance and thermal performance of green roof system
    He, Yang
    Yu, Hang
    Ozaki, Akihito
    Dong, Nannan
    Zheng, Shiling
    ENERGY, 2017, 141 : 1285 - 1299
  • [47] Effect of of irrigation on the experimental thermal performance of a green roof in a semi-warm climate in Mexico
    Chagolla-Aranda, M. A.
    Sima, E.
    Xaman, J.
    Alvarez, G.
    Hernandez-Perez, I.
    Tellez-Velazquez, E.
    ENERGY AND BUILDINGS, 2017, 154 : 232 - 243
  • [48] Experimental Investigation on Wide-span Cold-formed Steel Roof Truss System
    Mohammad, Shahrin
    Tahir, Mahmood Md
    Tan, Cher-Siang
    Shek, Poi-Ngian
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 1304 - 1307
  • [49] Comparative experimental study on the thermal and energy performance of photovoltaic and green roofs in hot-humid climates
    Zhan, Qiaosheng
    Ma, Yuchan
    Lin, Zhenghao
    Yin, Shi
    Xiao, Yiqiang
    BUILDING AND ENVIRONMENT, 2025, 271
  • [50] Energy performance of ETFE cushion roof integrated photovoltaic/thermal system on hot and cold days
    Hu, Jianhui
    Chen, Wujun
    Yang, Deqing
    Zhao, Bing
    Song, Hao
    Ge, Binbin
    APPLIED ENERGY, 2016, 173 : 40 - 51