Real-Time Monitoring of Power Quality for Web Based Electrical Power Panel Using LabVIEW

被引:0
|
作者
Nadhiroh, Isdawimah Nuha [1 ]
Aji, A. Damar [1 ]
Ismujianto [1 ]
机构
[1] Politekn Negeri Jakarta, Elect Dept, Depok, Indonesia
来源
2019 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND COMPUTER SCIENCE (ICECOS 2019) | 2019年
关键词
Harmonics; LabVIEW; monitoring; power quality;
D O I
10.1109/icecos47637.2019.8984441
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Utilization of electricity loads and the application of various power electronic equipment has experienced very rapid growth last years. Therefore, the power quality pollution is becoming a serious problem. This paper introduces a design and implementation of virtual instrument tool for real-time online monitoring of power quality using LabVIEW. Process of measuring an electrical or physical phenomenon in DAQ system is using NI cDAQ-9174 that consist of NI 9225 and NI9227 for voltage and current sensors, respectively. The system calculates and displays the waveform of three-phase current and voltage, frequency, power factor, the root mean square (RMS) value, and the total harmonic distortion (THD). The web based monitoring system function has been designed and integrated into the system that can be used to monitor electricity consumption on the customer's side. The experimental results show that the proposed power quality monitoring system can be implemented well and has an average error of 0.61%. The system can also be monitored via a web browser; https://monitoringpqpnj.com/lab2/. Different type of load (resistive, inductive, combination of R&L) are measured every second in 3 hours for the whole weekdays. The results show that the system voltage is -5.47% and +0.5% from nominal and the active power in each phase is not evenly distributed.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 50 条
  • [31] Real-Time Wireless Vibration Monitoring System Using LabVIEW
    Upadhye, Manish Y.
    Borole, P. B.
    Sharma, Ashok K.
    2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC), 2015, : 925 - 928
  • [32] Real-Time Power System Oscillation Monitoring using Synchrophasor Measurements
    van Rooyen, Tian
    Rens, Johan
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [33] Real-Time Aging Monitoring for Power MOSFETs Using Threshold Voltage
    Ren, Lei
    Shen, Qian
    Gong, Chunying
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 441 - 446
  • [34] Integrated circuit for real-time poly-phase power quality monitoring
    de Araujo, V. V.
    Simas Filho, E. F.
    Oliveira, A.
    de Oliveira, W. L. A.
    Esteves, L. T. C.
    MICROELECTRONICS JOURNAL, 2018, 79 : 57 - 63
  • [35] Real time data center intelligent power alarm monitoring using the web
    Silverman, Lionel
    2006 IEEE/PES Power Systems Conference and Exposition. Vols 1-5, 2006, : 1856 - 1859
  • [36] A real-time system for power quality testing
    Lakshmikanth, A
    Morcos, MM
    White, WN
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 1019 - 1023
  • [37] REAL-TIME POWER-SUPPLY QUALITY MEASUREMENT AND MONITORING MULTICHANNEL SYSTEM
    RUIZ, J
    ORTUONDO, J
    PALACIOS, N
    IZQUIERDO, J
    LETURIONDO, LA
    ARAMENDI, E
    AMANTEGUI, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) : 1190 - 1199
  • [38] An Efficient Frequency and Amplitude Tracking Method for Real-time Power Quality Monitoring
    Cai Tao
    Duan Shanxu
    Chen Changsong
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1766 - 1770
  • [39] Application of real-time operating system QNX in power quality monitoring system
    China University of Mining and Technology, Beijing 100083, China
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2006, 11 (79-82):
  • [40] A real-time system for power quality testing
    Lakshmikanth, A
    Morcos, MM
    White, WN
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (06) : 1464 - 1468