A Prospective Comparative Evaluation of Handheld Ultrasound Examination (HHUS) or Automated Ultrasound Examination (ABVS) in Women with Dense Breast

被引:3
作者
Brunetti, Nicole [1 ]
De Giorgis, Sara [1 ]
Tosto, Simona [2 ]
Garlaschi, Alessandro [2 ]
Rescinito, Giuseppe [2 ]
Massa, Barbara [3 ]
Calabrese, Massimo [2 ]
Tagliafico, Alberto Stefano [1 ,2 ]
机构
[1] Univ Genoa, Dept Hlth Sci DISSAL, Radiol Sect, Via LB Alberti 2, I-16132 Genoa, Italy
[2] IRCCS Osped Policlin San Martino, Dept Radiol, Largo Rosanna Benzi 10, I-16132 Genoa, Italy
[3] IRCCS Osped Policlin San Martino, Cytohistopathol Unit, Largo Rosanna Benzi 10, I-16132 Genoa, Italy
关键词
breast cancer; breast density; ultrasound; mammography; automated breast ultrasound; CANCER DETECTION; LESION DETECTION; MAMMOGRAPHY; VOLUME; TOMOSYNTHESIS; PERFORMANCE; ABUS; US;
D O I
10.3390/diagnostics12092170
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Mammography is the gold standard examination for breast cancer screening. In women with high breast density, mammography has reduced sensitivity. In these women, an additional screening option is often recommended. This study prospectively compared ABVS and HHUS in women with mammography-negative examinations and dense breasts. Materials and methods: N = 222 women were evaluated prospectively and consecutively between January 2019 and June 2019 (average age 53 years; range 39-89). McNemar's test and ROC analysis were used with standard statistical software. We included in the study both symptomatic and asymptomatic women with dense breasts. Women included underwent both HHUS and ABVS after mammography with independent reading. Results: N = 33/222 (15%) women resulted in having breast cancer. Both ABVS and HHUS identified more cancers than standard mammography, and both HHUS and ABVS had false-positive examinations: n = 13 for HHUS and n = 12 for ABVS. We found that HHUS had better accuracy than ABVS. The AUC of the ROC was 0.788 (95% CI 0.687-0.890) for ABVS and 0.930 (95% CI 0.868-0.993) for HHUS. This difference was statistically significant (p < 0.05). Conclusions: HHUS was more accurate in breast cancer detection than ABVS. Multicentric studies must confirm these data for supplemental imaging in women with dense breasts.
引用
收藏
页数:9
相关论文
共 28 条
[11]   Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breasts [J].
Kelly, Kevin M. ;
Dean, Judy ;
Comulada, W. Scott ;
Lee, Sung-Jae .
EUROPEAN RADIOLOGY, 2010, 20 (03) :734-742
[12]   Automated Breast Ultrasound Screening for Dense Breasts [J].
Kim, Sung Hun ;
Kim, Hak Hee ;
Moon, Woo Kyung .
KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (01) :15-24
[13]   Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound [J].
Kim, Sung Hun ;
Kang, Bong Joo ;
Choi, Byung Gil ;
Choi, Jae Jung ;
Lee, Ji Hye ;
Song, Byung Joo ;
Choe, Byung Joo ;
Park, Sarah ;
Kim, Hyunbin .
KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (02) :154-163
[14]   A Review of Breast Density Implications and Breast Cancer Screening [J].
Lian, Jingge ;
Li, Kangan .
CLINICAL BREAST CANCER, 2020, 20 (04) :283-290
[15]   The diagnostic performance of automated versus handheld breast ultrasound and mammography in symptomatic outpatient women: a multicenter, cross-sectional study in China [J].
Lin, Xi ;
Jia, Mengmeng ;
Zhou, Xiang ;
Bao, Lingyun ;
Chen, Yaqing ;
Liu, Peifang ;
Feng, Ruimei ;
Zhang, Xi ;
Zhu, Luoxi ;
Wang, Hui ;
Zhu, Ying ;
Tang, Guoxue ;
Feng, Wenqi ;
Li, Anhua ;
Qiao, Youlin .
EUROPEAN RADIOLOGY, 2021, 31 (02) :947-957
[16]   3D Supine Automated Ultrasound (SAUS, ABUS, ABVS) for Supplemental Screening Women with Dense Breasts [J].
Mundinger, Alexander .
JOURNAL OF BREAST HEALTH, 2016, 12 (02) :52-55
[17]   Automated Breast Ultrasound vs. Handheld Ultrasound: BI-RADS Classification, Duration of the Examination and Patient Comfort [J].
Prosch, H. ;
Halbwachs, C. ;
Strobl, C. ;
Reisner, L. -M. ;
Hondl, M. ;
Weber, M. ;
Mostbeck, G. H. .
ULTRASCHALL IN DER MEDIZIN, 2011, 32 (05) :504-510
[18]   Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use [J].
Rella, Rossella ;
Belli, Paolo ;
Giuliani, Michela ;
Bufi, Enida ;
Carlino, Giorgio ;
Rinaldi, Pierluigi ;
Manfredi, Riccardo .
ACADEMIC RADIOLOGY, 2018, 25 (11) :1457-1470
[19]   Automated Ultrasound of the Breast for Diagnosis: Interobserver Agreement on Lesion Detection and Characterization [J].
Shin, Hee Jung ;
Kim, Hak Hee ;
Cha, Joo Hee ;
Park, Ju Hyun ;
Lee, Kyoung Eun ;
Kim, Jeoung Hyun .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :747-754
[20]   A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2) [J].
Tagliafico, Alberto S. ;
Mariscotti, Giovanna ;
Valdora, Francesca ;
Durando, Manuela ;
Nori, Jacopo ;
La Forgia, Daniele ;
Rosenberg, Ilan ;
Caumo, Francesca ;
Gandolfo, Nicoletta ;
Sormani, Maria Pia ;
Signori, Alessio ;
Calabrese, Massimo ;
Houssami, Nehmat .
EUROPEAN JOURNAL OF CANCER, 2018, 104 :39-46