Effect of wind curtain on dust extraction in rock tunnel working face: CFD and field measurement analysis

被引:90
作者
Hua, Yun [1 ,2 ]
Nie, Wen [1 ,2 ]
Liu, Qiang [1 ,2 ]
Yin, Shuai [1 ,2 ]
Peng, Huitian [1 ,2 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofo, Qingdao 266590, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Dust pollution; Rock tunnel; Dust extraction; Exhaust air rate; Dust control wind curtain; MECHANIZED MINING FACE; GAS-PARTICLE FLOWS; EXTERNAL SPRAYING SYSTEM; LARGE-EDDY SIMULATION; ATOMIZATION CHARACTERISTICS; AIR-CURTAIN; STRUCTURAL PARAMETERS; INSTALLATION POSITION; NUMERICAL-SIMULATION; VENTILATION SYSTEMS;
D O I
10.1016/j.energy.2020.117214
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dust pollution in fully mechanized working faces of rock tunnels seriously threatens the safe operation and workers' health. In order to effectively control the dust and improve the working environment in the working face, we simulated the effect of dust suction position, d(s )and the exhaust air rate, Q(s) on dust diffusion at the working face by the CFD method. The accuracy and reliability of the numerical simulation were verified by field measurements. It was shown that when d(s) was 0, 1/4, 1/2, and 3/4, the overall airflow in the tunnel was in a disordered state. The dust, carried by the airflow, was eventually spread to the whole tunnel. When (s )was 1, an effective dust control wind curtain with the airflow direction pointing to the working face was achieved under the joint action of exhaust air and pressing air. A uniform flow covering the full section of the tunnel was formed within the range of 4.2-6.5m from the working face. The dust was controlled in an enclosed space between the road-header and the working face. When Q(s )was 330-500 m(3)/min, an effective dust control wind curtain was always formed in front of the roadheader. Consequently, the recommended air exhaust rate under the minimum energy consumption was 330 m(3)/min. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:25
相关论文
共 86 条
[81]   Synthesis and performance measurement of environment-friendly solidified dust suppressant for open pit coalmine [J].
Zhang, Haihan ;
Nie, Wen ;
Liu, Yanghao ;
Wang, Hongkun ;
Jin, Hu ;
Bao, Qiu .
JOURNAL OF APPLIED POLYMER SCIENCE, 2018, 135 (29)
[82]   Two-fluid turbulence modeling of swirling gas-particle flows - A review [J].
Zhou, Lixing .
POWDER TECHNOLOGY, 2017, 314 :253-263
[83]   Two-Phase Turbulence Models in Eulerian-Eulerian Simulation of Gas-Particle Flows and Coal Combustion [J].
Zhou, Lixing .
NEW PARADIGM OF PARTICLE SCIENCE AND TECHNOLOGY, PROCEEDINGS OF THE 7TH WORLD CONGRESS ON PARTICLE TECHNOLOGY, 2015, 102 :1677-1696
[84]   Optimization of dust removal performance of ventilation system in tunnel constructed using shield tunneling machine [J].
Zhou, Wenjie ;
Nie, Wen ;
Liu, Xiaofei ;
Zhou, Cong ;
Wei, Cunhou ;
Liu, Changqi ;
Liu, Qiang ;
Yin, Shuai .
BUILDING AND ENVIRONMENT, 2020, 173
[85]   Modelling of ventilation and dust control effects during tunnel construction [J].
Zhou, Wenjie ;
Nie, Wen ;
Liu, Changqi ;
Liu, Qiang ;
Wang Hetang ;
Wei, Cunhou ;
Yan, Jiayi ;
Yin, Shuai ;
Xiu, Zihao ;
Xu, Changwei .
INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2019, 160 :358-371
[86]  
ZHU CP, 2020, POWDER TECHNOL, DOI DOI 10.1016/J.POWTEC.2019.10.082