An environmental monitoring system for trace metals using stripping voltammetry

被引:65
作者
Desmond, D [1 ]
Lane, B
Alderman, J
Hill, M
Arrigan, DWM
Glennon, JD
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Lab B16, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Natl Microelect Res Ctr, Inst Adv Microelect, Cork, Ireland
[3] Univ Salford, Div Chem Sci, Sci Res Inst, Salford M5 4WT, Lancs, England
关键词
trace metals; ppb; anodic stripping voltammetry (ASV); reference electrode; disposable sensor;
D O I
10.1016/S0925-4005(98)00078-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is increasing pressure on industry and regulatory bodies to monitor the discharge of trace metals into the aquatic environment. The determination of trace metals can be.achieved to parts per billion (ppb) levels using anodic stripping voltammetry (ASV) at screen printed electrodes, controlled using an NMRC potentiostat coupled with software control. The disposable testheads consist of inexpensive materials and allow for low-cost production in batch processes. Voltammetric (the measurement of current as a function of potential) methods of analysis are attractive for the determination of copper, cadmium, lead and zinc. A three electrode set-up is used both in the preparation of the mercury film on a carbon electrode and in the subsequent anodic stripping voltammetric detection step. The performances of the reference electrodes, the screen-printed carbon and the FPGA based unit have been investigated in this paper. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 20 条
[11]  
REHN D, 1995, ANAL P, V32, P319
[12]  
RYAN JG, 1995, IEEE INT SOLID STATE
[13]   Novel potentiometric silicon sensor for medical devices [J].
Schnakenberg, U ;
Lisec, T ;
Hintsche, R ;
Kuna, I ;
Uhlig, A ;
Wagner, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :476-480
[14]  
SUCHOTIN AM, 1981, HDB ELECTROCHEMISTRY, P488
[15]  
UHLIG A, 1995, SENSOR ACTUAT B-CHEM, V24, P899
[16]   SCREEN-PRINTED ELECTRODES FOR STRIPPING MEASUREMENTS OF TRACE MERCURY [J].
WANG, J ;
TIAN, B .
ANALYTICA CHIMICA ACTA, 1993, 274 (01) :1-6
[17]   SCREEN-PRINTED ULTRAMICROELECTRODE ARRAYS FOR ON-SITE STRIPPING MEASUREMENTS OF TRACE-METALS [J].
WANG, J ;
LU, JM ;
TIAN, BM ;
YARNITZKY, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 361 (1-2) :77-83
[18]   SCREEN-PRINTED STRIPPING VOLTAMMETRIC POTENTIOMETRIC ELECTRODES FOR DECENTRALIZED TESTING OF TRACE LEAD [J].
WANG, J ;
TIAN, BM .
ANALYTICAL CHEMISTRY, 1992, 64 (15) :1706-1709
[19]   MERCURY-FREE DISPOSABLE LEAD SENSORS BASED ON POTENTIOMETRIC STRIPPING ANALYSIS AT GOLD-COATED SCREEN-PRINTED ELECTRODES [J].
WANG, J ;
TIAN, B .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1529-1532
[20]  
Wang J., 1985, STRIPPING ANAL PRINC