ISCEV Standard for full-field clinical electroretinography (2015 update)

被引:1113
作者
McCulloch, Daphne L. [1 ]
Marmor, Michael F. [2 ]
Brigell, Mitchell G. [3 ]
Hamilton, Ruth [4 ,5 ]
Holder, Graham E. [6 ]
Tzekov, Radouil [7 ]
Bach, Michael [8 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON N2L 3G1, Canada
[2] Stanford Univ, Sch Med, Dept Ophthalmol, Byers Eye Inst, Stanford, CA 94305 USA
[3] Aerpio Therapeut, Clin Res Ophthalmol, Cincinnati, OH USA
[4] NHS Greater Glasgow & Clyde, Royal Hosp Sick Children, Dept Clin Phys, Glasgow, Lanark, Scotland
[5] Univ Glasgow, Coll Med Vet & Life Sci, Glasgow, Lanark, Scotland
[6] Moorfields Eye Hosp, London, England
[7] Univ S Florida, Dept Ophthalmol, Tampa, FL USA
[8] Univ Freiburg, Ctr Eye, Sect Visual Funct, D-79106 Freiburg, Germany
关键词
Clinical standards; Electroretinogram (ERG); Full-field ERG; International Society of Clinical Electrophysiology of Vision (ISCEV);
D O I
10.1007/s10633-014-9473-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for full-field clinical electroretinography (ffERG or simply ERG). The parameters for Standard flash stimuli have been revised to accommodate a variety of light sources including gas discharge lamps and light emitting diodes. This ISCEV Standard for clinical ERGs specifies six responses based on the adaptation state of the eye and the flash strength: (1) Dark-adapted 0.01 ERG (rod ERG); (2) Dark-adapted 3 ERG (combined rod-cone standard flash ERG); (3) Dark-adapted 3 oscillatory potentials; (4) Dark-adapted 10 ERG (strong flash ERG); (5) Light-adapted 3 ERG (standard flash "cone" ERG); and (6) Light-adapted 30 Hz flicker ERG. ISCEV encourages the use of additional ERG protocols for testing beyond this minimum standard for clinical ERGs.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 7 条
  • [1] ISCEV standard for clinical pattern electroretinography (PERG): 2012 update
    Bach, Michael
    Brigell, Mitchell G.
    Hawlina, Marko
    Holder, Graham E.
    Johnson, Mary A.
    McCulloch, Daphne L.
    Meigen, Thomas
    Viswanathan, Suresh
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2013, 126 (01) : 1 - 7
  • [2] Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision
    Brigell, M
    Bach, M
    Barber, C
    Moskowitz, A
    Robson, J
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (02) : 185 - 193
  • [3] ISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition)
    Hood, Donald C.
    Bach, Michael
    Brigell, Mitchell
    Keating, David
    Kondo, Mineo
    Lyons, Jonathan S.
    Marmor, Michael F.
    McCulloch, Daphne L.
    Palmowski-Wolfe, Anja M.
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2012, 124 (01) : 1 - 13
  • [4] ISCEV Standard for full-field clinical electroretinography (2008 update)
    Marmor, M. F.
    Fulton, A. B.
    Holder, G. E.
    Miyake, Y.
    Brigell, M.
    Bach, M.
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2009, 118 (01) : 69 - 77
  • [5] MARMOR MF, 1989, ARCH OPHTHALMOL-CHIC, V107, P816, DOI 10.1007/BF00154486
  • [6] ISCEV standard for clinical electro-oculography (2010 update)
    Marmor, Michael F.
    Brigell, Mitchell G.
    McCulloch, Daphne L.
    Westall, Carol A.
    Bach, Michael
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2011, 122 (01) : 1 - 7
  • [7] ISCEV standard for clinical visual evoked potentials (2009 update)
    Odom, J. Vernon
    Bach, Michael
    Brigell, Mitchell
    Holder, Graham E.
    McCulloch, Daphne L.
    Tormene, Alma Patrizia
    Vaegan