Percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion: a radiological and cadaveric study

被引:7
|
作者
Wu, Ai-Min [1 ]
Ni, Wen-Fei [1 ]
Shao, Zhen-Xuan [1 ]
Kong, Xiang-Jie [1 ]
Tian, Nai-Feng [1 ]
Huang, Yi-Xing [1 ]
Lin, Zhong-Ke [1 ]
Xu, Hua-Zi [1 ]
Chi, Yong-Long [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Zhejiang Spinal Res Ctr, Dept Spinal Surg, Wenzhou 325027, Zhejiang, Peoples R China
关键词
Percutaneous; Oblique lumbar screw fixation; Transdiscal screw fixation; Lateral interbody fusion; Minimally invasive; LUMBAR; SURGERY;
D O I
10.1007/s00586-014-3663-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To design and investigate a novel technique of percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion. CT scans of 45 patients were collected and imported into Mimics software for three-dimensional (3D) reconstruction. Cylinders were drawn to simulate the trajectory of the oblique screw. Six measurements were obtained for each unit to design a right size cage: a the distance between the intersection of the simulated trajectory of the screw with the inferior border of the upper vertebra and its anteroinferior corner; b the distance between the intersection of the simulated trajectory of the screw with the superior border of the inferior vertebra and its anterosuperior corner; h the height of the intervertebral space; theta the angle between simulated trajectory of screw and the upper endplate of inferior vertebra; uw: the width of the inferior endplate of upper vertebra; iw: the width of upper endplate of inferior vertebra. Three intact adult fresh-frozen cadaveric specimens were obtained, percutaneous posterior transdiscal oblique screw fixation was performed under X-ray apparatus, and interbody cage was implanted by assistance with special self-retaining retractor system and endoscope. According to the results of data measured from 3D images, trapezoid shape interbody cages with suitable size were designed. Percutaneous posterior oblique screw fixation with lateral interbody fusion was performed on three cadaveric specimens successfully. Using specially designed trapezoid shape interbody cages, assisted by intra-operative image intensification and endoscope, it is feasible to perform percutaneous posterior transdiscal oblique screw fixation with lateral interbody fusion technique.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 50 条
  • [31] Prospective evaluation of 1-year outcomes in single-level percutaneous lumbar transfacet screw fixation in the lateral decubitus position following lateral transpsoas interbody fusion
    Rhee, Jay W.
    Petteys, Rory J.
    Anaizi, Amjad N.
    Sandhu, Faheem A.
    Voyadzis, Jean-Marc
    EUROPEAN SPINE JOURNAL, 2015, 24 (11) : 2546 - 2554
  • [32] The Influence of Screw Positioning on Cage Subsidence in Patients with Oblique Lumbar Interbody Fusion Combined with Anterolateral Fixation
    Wang, Kai
    Wang, Xiandi
    Li, Zhuhai
    Xie, Tianhang
    Wang, Lihang
    Luo, Chuan
    Huang, Shishu
    Zeng, Jiancheng
    ORTHOPAEDIC SURGERY, 2023, 15 (12) : 3263 - 3271
  • [33] Biomechanical evaluation of two-level oblique lumbar interbody fusion combined with posterior four-screw fixation:A finite element analysis
    Ge, Ting
    Hu, Baiwen
    Zhang, Qiaolin
    Xiao, Jin
    Wu, Xiaochuan
    Xia, Dongdong
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2023, 225
  • [34] Comparison of transforaminal lumbar interbody fusion performed with unilateral pedicle screw fixation or unilateral pedicle screw-contralateral percutaneous transfacet screw fixation
    Luo, Peng
    Chen, Yi-Heng
    Wu, Yao-Sen
    Dou, Hai-Cheng
    Chi, Yong-Long
    Lin, Yan
    BRITISH JOURNAL OF NEUROSURGERY, 2016, 30 (01) : 86 - 90
  • [35] Clinical and Radiologic Comparisons Between Oblique Lumbar Interbody Fusion Combined with Percutaneous Pedicle Screw Fixation and Transforaminal Lumbar Interbody Fusion for Adult Isthmic Spondylolisthesis: A 2-year Follow-Up Study
    Jung, Choong-Won
    Soh, Jaewan
    Park, Jin-Sung
    Park, Se-Jun
    Lee, Chong-Suh
    Kim, Hyun-Jun
    WORLD NEUROSURGERY, 2025, 193 : 605 - 612
  • [36] Lateral lumbar interbody fusion via a unilateral true percutaneous approach associated with minimally invasive pedicle screw fixation for degenerative disc disease and lumbar instability
    Agrillo, U.
    Panagiotopoulos, K.
    Corbino, L.
    Schettini, G.
    Puzzilli, F.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2010, 54 (02) : 65 - 69
  • [37] Posterior Lumbar Interbody Fusion: Comparison of Single Intervertebral Cage and Single Side Pedicle Screw Fixation versus Bilateral Cages and Screw Fixation
    Moreland, D. B.
    Asch, H. L.
    Czajka, G. A.
    Overkamp, J. A.
    Sitzman, D. M.
    MINIMALLY INVASIVE NEUROSURGERY, 2009, 52 (03) : 132 - 136
  • [38] Comparing oblique lumbar interbody fusion with lateral screw fixation and percutaneous endoscopic transforaminal discectomy (OLIF-PETD) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of lumbar disc herniation complicated with lumbar instability
    Deng, Chen
    Feng, Haoyu
    Ma, Xun
    Chen, Chen
    Mei, Jun
    Sun, Lin
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [39] Minimally Invasive Lateral Lumbar Interbody Fusion for Clinical Adjacent Segment Pathology A Comparative Study With Conventional Posterior Lumbar Interbody Fusion
    Park, Hyung-Youl
    Kim, Young-Hoon
    Ha, Kee-Yong
    Kim, Sang-Il
    Min, Hyung-Ki
    Oh, In-Soo
    Seo, Jun-Yeong
    Chang, Dong-Gune
    Park, Jong-Tae
    CLINICAL SPINE SURGERY, 2019, 32 (10): : 2019 - E433
  • [40] Oblique, Unilateral, or Bilateral Rods Configurations for Single-Level Interbody Fusion and Posterior Spinal Fixation: A Finite Element Study
    Redaelli, Andrea
    Panico, Matteo
    Cecchinato, Riccardo
    Damilano, Marco
    Vanni, Daniele
    Ponzo, Matteo
    Galbusera, Fabio
    Langella, Francesco
    TURKISH NEUROSURGERY, 2023, 33 (04) : 584 - 590