Real-time system for respiratory-cardiac gating in positron tomography

被引:99
作者
Klein, GJ
Reutter, BW
Ho, MH
Reed, JH
Huesman, RH
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Ctr Funct Imaging, Berkeley, CA 94720 USA
[2] CTI Inc, Knoxville, TN 37932 USA
关键词
D O I
10.1109/23.708323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Macintosh-based signal processing system has been developed to support simultaneous respiratory and cardiac gating on the ECAT EXACT HR PET scanner. Using the Lab-View real-time software environment, the system reads analog inputs from a pneumatic respiratory bellows and an ECG monitor to compute an appropriate histogram memory location for the PET data. Respiratory state is determined by the bellows signal amplitude; cardiac state is based on the time since the last R-wave. These two states are used in a 2D lookup table to determine a combined respiratory-cardiac state. A 4-bit address encoding the selected histogram is directed from the system to the ECAT scanner, which dynamically switches the destination of tomograph events as respiratory-cardiac state changes. To test the switching efficiency of the combined Macintosh/ECAT system, a rotating emission phantom was built, Acquisitions with 25 msec states while the phantom was rotating at 240 rpm demonstrate the system could effectively stop motion at this rate, with approximately 5 msec switching time between states.
引用
收藏
页码:2139 / 2143
页数:5
相关论文
共 11 条
[1]  
Budinger T. F., 1996, Journal of Nuclear Medicine, V37, p130P
[2]   THE ELECTRONICS FOR THE DONNER 600-CRYSTAL POSITRON TOMOGRAPH [J].
CAHOON, JL ;
HUESMAN, RH ;
DERENZO, SE ;
GEYER, AB ;
UBER, DC ;
TURKO, BT ;
BUDINGER, TF .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :570-574
[3]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE [J].
HOFFMAN, EJ ;
HUANG, SC ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) :299-308
[4]  
Huesman R. H., 1997, Journal of Nuclear Medicine, V38, p114P
[5]   Non-rigid summing of gated PET via optical flow [J].
Klein, GJ ;
Reutter, BW ;
Huesman, RH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) :1509-1512
[6]   A 3D optical flow approach to addition of deformable PET volumes [J].
Klein, GJ ;
Huesman, RH .
IEEE NONRIGID AND ARTICULATED MOTION WORKSHOP, PROCEEDINGS, 1997, :136-143
[7]   PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY [J].
MOORE, SC ;
JUDY, PF ;
GARNIC, JD ;
KAMBIC, GX ;
BONK, F ;
COCHRAN, G ;
MARGOSIAN, P ;
MCCROSKEY, W ;
FOOTE, F .
MEDICAL PHYSICS, 1983, 10 (06) :846-855
[8]   EFFICIENT BIPHASIC SPIN-ECHO MAGNETIC-RESONANCE IMAGING [J].
PARKER, DL ;
CAPUTO, GR ;
FREDERICK, PR .
MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) :98-113
[9]  
Reutter B. W., 1997, Journal of Nuclear Medicine, V38, p203P
[10]   Automated 3-D segmentation of respiratory-gated PET transmission images [J].
Reutter, BW ;
Klein, GJ ;
Huesman, RH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) :2473-2476