Ex Vivo Evaluation of a Pressure-Sensitive Device to Aid Big Bubble Intrastromal Dissection in Deep Anterior Lamellar Keratoplasty

被引:1
作者
Iovieno, Alfonso [1 ,2 ]
Fontana, Luigi [2 ]
Coassin, Marco [2 ,3 ]
Bovio, Dario [4 ]
Salito, Caterina [4 ]
机构
[1] Univ British Columbia, Dept Ophthalmol & Visual Sci, Vancouver, BC, Canada
[2] IRCCS Azienda Osped Univ Bologna, Bologna, Italy
[3] Univ Campus Bio Med, Dept Ophthalmol, Rome, Italy
[4] Biocub Biomed Engn, Milan, Italy
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2022年 / 11卷 / 12期
关键词
DALK; big bubble; medical device; keratoplasty; OPTICAL COHERENCE TOMOGRAPHY; PENETRATING KERATOPLASTY; CORNEAL TRANSPLANTATION; DESCEMETS-MEMBRANE; KERATOCONUS; OUTCOMES;
D O I
10.1167/tvst.11.12.17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop and perform ex vivo testing for a device designed for semiquantitative determination of intracorneal dissection depth during big bubble (BB) deep anterior lamellar keratoplasty. Methods: A prototype device connected to a syringe and cannula was designed to determine depth of intrastromal placement based on air rebound pressure emitted by a software controlled generator. Ex vivo testing of the device was conducted on human corneas mounted on an artificial anterior chamber in three experiments: (1) cannula purposely introduced at different depths measured with anterior segment optical coherence tomography, (2) cannula introduced as per the BB technique, and (3) simulation of the BB technique guided by the device. Results: A positive pressure differential and successful BB were observed only when the cannula was positioned within 150 microns from the endothelial plane. In all successful BB cases (21/40), a repeatable increase in tissue rebound pressure was detected, which was not recorded in unsuccessful cases. The device was able to signal to the surgeon correct placement of the cannula (successful BB) in 16 of 17 cases and incorrect placement of the cannula (unsuccessful BB) in 8 of 8 cases (94.1% sensitivity, 100% specificity). Conclusions: In our ex vivo model, this novel medical device could reliably signal cannula positioning in the deep stroma for effective pneumatic dissection and possibly aid technical execution of BB deep anterior lamellar keratoplasty. Translational Relevance: A medical device that standardizes big bubble deep anterior lamellar keratoplasty could increase the overall success rate of the surgical procedure and aid popularization of deep anterior lamellar keratoplasty.
引用
收藏
页数:8
相关论文
共 36 条
  • [1] [Anonymous], 2021, 2021 EYE BANK ASS AM
  • [2] Big-bubble technique to bare Descemet's membrane in anterior lamellar keratoplasty
    Anwar, M
    Teichmann, KD
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03) : 398 - 403
  • [3] Long-term Results of Deep Anterior Lamellar versus Penetrating Keratoplasty
    Borderie, Vincent M.
    Sandali, Otman
    Bullet, Julien
    Gaujoux, Thomas
    Touzeau, Olivier
    Laroche, Laurent
    [J]. OPHTHALMOLOGY, 2012, 119 (02) : 249 - 255
  • [4] Chaniyara Manthan Hasmukhbhai, 2017, BMJ Case Rep, V2017, DOI 10.1136/bcr-2017-221495
  • [5] Deep Anterior Lamellar Keratoplasty Versus Penetrating Keratoplasty: A Meta-Analysis of Randomized Controlled Trials
    Chen, Guohai
    Tzekov, Radouil
    Li, Wensheng
    Jiang, Fangzheng
    Mao, Sihong
    Tong, Yuhua
    [J]. CORNEA, 2016, 35 (02) : 169 - 174
  • [6] Endothelial Cell Loss and Visual Outcome of Deep Anterior Lamellar Keratoplasty versus Penetrating Keratoplasty: A Randomized Multicenter Clinical Trial
    Cheng, Yanny Y. Y.
    Visser, Nienke
    Schouten, Jan S.
    Wijdh, Robert-Jan
    Pels, Elisabeth
    van Cleynenbreugel, Hugo
    Eggink, Catharina A.
    Zaal, Michel J. W.
    Rijneveld, Wilhelmina J.
    Nuijts, Rudy M. M. A.
    [J]. OPHTHALMOLOGY, 2011, 118 (02) : 302 - 309
  • [7] Intraoperative Anterior Segment Optical Coherence Tomography: A Novel Assessment Tool during Deep Anterior Lamellar Keratoplasty
    De Benito-Llopis, Laura
    Mehta, Jodhbir S.
    Angunawela, Romesh I.
    Ang, Marcus
    Tan, Donald T. H.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) : 334 - 341
  • [8] Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty
    Draelos, Mark
    Tang, Gao
    Keller, Brenton
    Kuo, Anthony
    Hauser, Kris
    Izatt, Joseph A.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (07) : 2073 - 2083
  • [9] Dynamics of big bubble formation in deep anterior lamellar keratoplasty by the big bubble technique: invitro studies
    Dua, Harminder S.
    Faraj, Lana A.
    Kenawy, Mohamed B.
    AlTaan, Saief
    Elalfy, Mohamed S.
    Katamish, Tarek
    Said, Dalia G.
    [J]. ACTA OPHTHALMOLOGICA, 2018, 96 (01) : 69 - 76
  • [10] Big-bubble deep anterior lamellar keratoplasty using central vs peripheral air injection: a clinical trial
    Feizi, Sepehr
    Daryabari, Seyed-Hashem
    Najdi, Danial
    Javadi, Mohammad Ali
    Karimian, Farid
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (04) : 297 - 302