Effect of Cementless Acetabular Component Orientation, Position, and Containment in Total Hip Arthroplasty for Congenital Hip Disease

被引:50
|
作者
Georgiades, George [1 ]
Babis, George C. [2 ]
Kourlaba, Georgia [3 ]
Hartofilakidis, George [4 ]
机构
[1] Dept Tripoli Hosp, Athens 11525, Greece
[2] Univ Athens, Sch Med, Dept Orthoped 1, Athens 14576, Greece
[3] Harokopio Univ, Off Biostat, Athens 11528, Greece
[4] Univ Athens, Sch Med, Athens 11471, Greece
关键词
cementless acetabular component; position; orientation; containment; congenital hip disease; LOW-FRICTION ARTHROPLASTY; FOLLOW-UP; DEVELOPMENTAL DYSPLASIA; POLYETHYLENE WEAR; FEMORAL COMPONENTS; PELVIC OSTEOLYSIS; DISLOCATION; REPLACEMENT; PLACEMENT; ADULTS;
D O I
10.1016/j.arth.2009.12.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated the effect of the inclination angle, position, and containment of 53 cementless cups inserted in patients with congenital hip disease (CHD), after a minimum of 10 years of follow-up. The polyethylene wear rate was significantly greater when the cup was placed in more than 45 degrees inclination (P = .045) or if the cup was placed lateral to the teardrop position by more than 25 mm (P = .001). Aseptic loosening of the femoral component was significantly greater when the cup was placed more than 25 mm superiorly to the teardrop (P = .049). Cup placement of more than 25 mm lateral to the teardrop affected significantly periacetabular osteolysis (P = .032). In CHD cases, it is preferable to avoid excessive vertical inclination, lateral, and superior placement of cementless cups in an attempt to obtain better containment.
引用
收藏
页码:1143 / 1150
页数:8
相关论文
共 50 条
  • [41] Acetabular Components in Total Hip Arthroplasty: Is There Evidence That Cementless Fixation Is Better?
    Toossi, Nader
    Adeli, Bahar
    Timperley, Andrew J.
    Haddad, Fares S.
    Maltenfort, Mitchell
    Parvizi, Javad
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (02) : 168 - 174
  • [42] The outcome of cementless total hip arthroplasty in haemophilic hip arthropathy
    Yoo, M. C.
    Cho, Y. J.
    Kim, K. I.
    Ramteke, A.
    Chun, Y. S.
    HAEMOPHILIA, 2009, 15 (03) : 766 - 773
  • [43] Redefining the Acetabular Component Safe Zone for Posterior Approach Total Hip Arthroplasty
    Danoff, Jonathan R.
    Bobman, Jacob T.
    Cunn, Gregory
    Murtaugh, Taylor
    Gorroochurn, Prakash
    Geller, Jeffrey A.
    Macaulay, William
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02) : 506 - 511
  • [44] Digitalized analyses of intraoperative acetabular component position using image-matching technique in total hip arthroplasty
    Kawahara, S.
    Hara, T.
    Sato, T.
    Kitade, K.
    Shimoto, T.
    Nakamura, T.
    Mawatari, T.
    Higaki, H.
    Nakashima, Y.
    BONE & JOINT RESEARCH, 2020, 9 (07): : 360 - 367
  • [45] Acetabular component position significantly influences the rebalancing of pelvic sagittal inclination following total hip arthroplasty in patients with Crowe type III/IV developmental dysplasia of the hip
    Zhai, Z.
    Zhang, J.
    Li, H.
    Mao, Y.
    Zhu, Z.
    Zhao, J.
    Yu, D.
    Zhao, C.
    BONE & JOINT JOURNAL, 2025, 107B (02) : 149 - 156
  • [46] Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia
    Bicanic, Goran
    Delimar, Domagoj
    Delimar, Marko
    Pecina, Marko
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 397 - 402
  • [47] Inferomedial Hip Center Decreases Failure Rates in Cementless Total Hip Arthroplasty for Crowe II and III Hip Dysplasia
    Watts, Chad D.
    Martin, John R.
    Fehring, Keith A.
    Griffin, William L.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : 2177 - 2181
  • [48] A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip Arthroplasty
    Dorr, Lawrence D.
    Wan, Zhinian
    Malik, Aamer
    Zhu, Jinjun
    Dastane, Manish
    Deshmane, Prashant
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) : 2598 - 2604
  • [49] The effect of orientation of the acetabular component on outcome following total hip arthroplasty with small diameter hard-on-soft bearings
    Grammatopoulos, G.
    Thomas, G. E. R.
    Pandit, H.
    Beard, D. J.
    Gill, H. S.
    Murray, D. W.
    BONE & JOINT JOURNAL, 2015, 97B (02) : 164 - 172
  • [50] Catastrophic Wear of an Acetabular Component Misdiagnosed as Total Hip Arthroplasty Dislocation
    Papaioannou, Ioannis
    Pantazidou, Georgia
    Chatziperi, Stamatia
    Baikousis, Andreas
    Korovessis, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (11)