Noise and Sensitivity Analysis of Harmonic Radar System for Vital Sign Detection

被引:0
作者
Chioukh, Lydia [1 ]
Boutayeb, Halim [1 ]
Deslandes, Dominic [2 ]
Wu, Ke [1 ]
机构
[1] Ecole Polytech, Ctr Radiofrequency Elect Res Quebec CREER, Dept Elect Engn, Poly GRAMES Res Ctr, Montreal, PQ H3C 3A7, Canada
[2] Univ Quebec, Montreal, PQ H3C 3P8, Canada
来源
2013 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO) | 2013年
关键词
Harmonic radar; vital sign detection; noise; sensitivity; heartbeat rate; multi-frequency; flicker noise;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Harmonic radar architectures present systems of wireless detection operating at multiple harmonic carrier frequencies. The noise and sensitivity of a harmonic radar system, which is developed at 12 GHz and 24 GHz for vital signs detection, are studied numerically and experimentally. The received signal power of the radar system is analyzed numerically as a function of the distance, taking into account the radar cross section (RCS) of the patient chest. The numerical data are compared with results obtained with single carrier frequency system. The total noise is a combination of thermal noise, residual phase noise, and flicker noise that presents the most elevated factor influencing the detection at baseband. Experimental results show that with the harmonic radar, the flicker noise can be reduced by 20dB at around 1Hz baseband frequency.
引用
收藏
页码:163 / 165
页数:3
相关论文
共 8 条
  • [1] Budge M. C. Jr., 1993, Proceedings IEEE Southeastcon '93 (Cat. No.93CH3295-3), DOI 10.1109/SECON.1993.465731
  • [2] Chioukh L, 2012, EUR MICROW CONF, P25
  • [3] 60-GHz Millimeter-Wave Life Detection System (MLDS) for Noncontact Human Vital-Signal Monitoring
    Chuang, Huey-Ru
    Kuo, Hsin-Chih
    Lin, Fu-Ling
    Huang, Tzuen-Hsi
    Kuo, Chi-Shin
    Ou, Ya-Wen
    [J]. IEEE SENSORS JOURNAL, 2012, 12 (03) : 602 - 609
  • [4] Noise in RF-CMOS mixers: A simple physical model
    Darabi, H
    Abidi, AA
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2000, 35 (01) : 15 - 25
  • [5] Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
    Droitcour, AD
    Boric-Lubecke, O
    Lubecke, VM
    Lin, JS
    Kovacs, GTA
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (03) : 838 - 848
  • [6] A quadrature radar topology with Tx leakage canceller for 24-GHz radar applications
    Kim, Choul-Young
    Kim, Jeong-Geun
    Hong, Songcheol
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (07) : 1438 - 1444
  • [7] NONINVASIVE MICROWAVE MEASUREMENT OF RESPIRATION
    LIN, JC
    [J]. PROCEEDINGS OF THE IEEE, 1975, 63 (10) : 1530 - 1530
  • [8] Noise considerations for remote detection of life signs with microwave Doppler radar
    Nguyen, Dung
    Yamada, Shuhei
    Park, Byung-Kwon
    Lubecke, Victor
    Boric-Lubecke, Olga
    Host-Madsen, Anders
    [J]. 2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1667 - 1670