Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT

被引:13
|
作者
Gong, Hao [1 ]
Marsh, Jeffrey F. [1 ]
D'Souza, Karen N. [1 ]
Huber, Nathan R. [1 ]
Rajendran, Kishore [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia H. [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
virtual monoenergetic image; dual-energy CT; deep learning; convolutional neural network; photon counting detector; noise reduction; artifact reduction; PULMONARY ANGIOGRAPHY; NOISE-REDUCTION; SINGLE-SOURCE; IODINE LOAD; CONTRAST; RECONSTRUCTION; QUALITY; EXTRAPOLATION; EXPERIENCE; ACCURACY;
D O I
10.1117/1.JMI.8.5.052104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We developed a deep learning method to reduce noise and beam-hardening artifact in virtual monoenergetic image (VMI) at low x-ray energy levels. Approach: An encoder-decoder type convolutional neural network was implemented with customized inception modules and in-house-designed training loss (denoted as Incept-net), to directly estimate VMI from multi-energy CT images. Images of an abdomen-sized water phantom with varying insert materials were acquired from a research photon-counting-detector CT. The Incept-net was trained with image patches (64 x 64 pixels) extracted from the phantom data, as well as synthesized, random-shaped numerical insert materials. The whole CT images (512 x 512 pixels) with the remaining real insert materials that were unseen in network training were used for testing. Seven contrast-enhanced abdominal CT exams were used for preliminary evaluation of Incept-net generalizability over anatomical background. Mean absolute percentage error (MAPE) was used to evaluate CT number accuracy. Results: Compared to commercial VMI software, Incept-net largely suppressed beam-hardening artifact and reduced noise (53%) in phantom study. Incept-net presented comparable CT number accuracy at higher-density (P-value [0.0625, 0.999]) and improved it at lower-density inserts (P-value=0.0313) with overall MAPE: Incept-net [2.9%, 4.6%]; commercial-VMI [6.7%, 10.9%]. In patient images, Incept-net suppressed beam-hardening artifact and reduced noise (up to 50%, P-value=0.0156). Conclusion: In this preliminary study, Incept-net presented the potential to improve low-energy VMI quality. (C) 2021 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms
    Greffier, Joel
    Van Ngoc Ty, Claire
    Fitton, Isabelle
    Frandon, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (19)
  • [2] Deep learning-based reconstruction of virtual monoenergetic images of kVp-switching dual energy CT for evaluation of hypervascular liver lesions: Comparison with standard reconstruction technique
    Seo, June Young
    Joo, Ijin
    Yoon, Jeong Hee
    Kang, Hyo Jin
    Kim, Sewoo
    Kim, Jong Hyo
    Ahn, Chulkyun
    Lee, Jeong Min
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [3] Low-KeV Virtual Monoenergetic Dual-Energy CT with Deep Learning Reconstruction for Assessing Hepatocellular Carcinoma
    Ota, Takashi
    Nakamoto, Atsushi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Matsumoto, Shohei
    Fukui, Hideyuki
    Kaketaka, Koki
    Honda, Toru
    Kiso, Kengo
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (02) : 293 - 306
  • [4] Energy-Specific Optimization of Attenuation Thresholds for Low-Energy Virtual Monoenergetic Images in Renal Lesion Evaluation
    Patel, Bhavik N.
    Farjat, Alfredo
    Schabel, Christoph
    Duvnjak, Petar
    Mileto, Achille
    Ramirez-Giraldo, Juan Carlos
    Marin, Daniele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : W205 - W217
  • [5] Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [6] Deep learning-based image reconstruction of 40-keV virtual monoenergetic images of dual-energy CT for the assessment of hypoenhancing hepatic metastasis
    Lee, Taehee
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Bae, Jae Seok
    Yoo, Jeongin
    Kim, Jae Hyun
    Ahn, Chulkyun
    Kim, Jong Hyo
    EUROPEAN RADIOLOGY, 2022, 32 (09) : 6407 - 6417
  • [7] Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis
    Lahuna, Loris
    Greffier, Joel
    Goupil, Jean
    Frandon, Julien
    Pastor, Maxime
    De Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (23)
  • [8] The synthesis of high-energy CT images from low-energy CT images using an improved cycle generative adversarial network
    Zhou, Haojie
    Liu, Xinfeng
    Wang, Haiyan
    Chen, Qihang
    Wang, Rongpin
    Pang, Zhi-Feng
    Zhang, Yong
    Hu, Zhanli
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 28 - 42
  • [9] Performance improvements of virtual monoenergetic images in photon-counting detector CT compared with dual source dual-energy CT: Fourier-based assessment
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Yoshida, Ryoichi
    Katayama, Takuto
    Arimoto, Makoto
    Kataoka, Jun
    Nagata, Hiroji
    Kobayashi, Satoshi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, : 143 - 153
  • [10] A Deep-Learning-Based Optimal Energy Flow Method for Reliability Assessment of Integrated Energy Systems
    Dong, Ziheng
    Hou, Kai
    Liu, Zeyu
    Yu, Xiaodan
    Jia, Hongjie
    Xiao, Qian
    IEEE ACCESS, 2022, 10 : 91092 - 91102