共 25 条
Efficacy of Cataract Surgery With Trabecular Microbypass Stent Implantation in Combined-Mechanism Angle Closure Glaucoma Patients
被引:17
作者:
Chansangpetch, Sunee
[1
,2
,3
]
Lau, Kevin
[1
]
Perez, Claudio, I
[1
,4
]
Ngoc Nguyen
[5
]
Porco, Travis C.
[1
]
Lin, Shan C.
[1
,6
]
机构:
[1] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
[2] Chulalongkorn Univ, Fac Med, Glaucoma Res Unit, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Thai Red Cross Soc, Bangkok, Thailand
[4] Univ los Andes, Fdn Oftalmol Los Andes, Santiago, Chile
[5] Ngoc Nguyen Eye Clin, San Jose, CA USA
[6] Glaucoma Ctr San Francisco, San Francisco, CA USA
关键词:
MANCHESTER ISTENT;
LENS EXTRACTION;
PHACOEMULSIFICATION;
CONFIGURATION;
D O I:
10.1016/j.ajo.2018.08.003
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE: To evaluate the effectiveness of trabecular microbypass stent (iStent) implantation in combined mechanism glaucoma (CMG). DESIGN: Retrospective cohort study. METHODS: We reviewed the medical charts of patients with the following scenarios: (1) primary open-angle glaucoma (POAG) undergoing phacoemulsification (PE), (2) POAG undergoing PE with iStent (POAG-PE/iStent), (3) CMG undergoing PE (CMG-PE), and (4) CMG undergoing PE with iStent (CMG-PE/iStent). CMG was defined as narrow-angle glaucoma patients whose angle had opened after iridotomy. Linear mixed-effects models were performed to determine the effect of iStent on postoperative 1-year success rate (intraocular pressure [IOP] <= 18 without medication), TOP, and number of medications. RESULTS: Data from 301 eyes were available. The number of eyes (subjects) was 61 (45) in the POAG-PE, 60 (50) in POAG-PE/iStent, 93 (76) in CMG-PE, and 87 (70) in CMG-PE/iStent group. Success criteria were achieved in 13.1% for POAG-PE, 33.3% for POAG-PE/iStent (POAG-PE vs POAG-PE/iStent B 3.01; P < .001), 37.6% for CMG-PE, and 43.7% for CMG-PE/iStent (CMG-PE vs CMG-PE/iStent B 2.25; P < .001). There was no difference in the IOP between POAG-PE and POAG-PE/iStent, and between CMG-PE and CMG-PE/iStent. The iStent significantly reduced number of medications in the POAG (B - 0.70; P < .001) and CMG group (B -0.52; P < .001). Comparing the effect of iStent on POAG and CMG, the analysis showed similar iStent efficacy in terms of the success rate, IOP, and number of medications (P > .05). CONCLUSIONS: Combined PE/iStent significantly increased success rate and reduced number of medications in CMG patients compared to PE alone. The effects of iStent were comparable between POAG and CMG groups. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:191 / 198
页数:8
相关论文