A comparison of a monofocal acrysoft IOL using the "blended monovision" formula with the multifocal array IOL for glasses independence after cataract surgery

被引:18
作者
Chen, Ming
Atebara, Neal H.
Chen, Te Tsaw
机构
[1] Univ Hawaii, Sch Med, Honolulu, HI 96813 USA
[2] Taipei Med Univ, Dept Ophthalmol, Taipei, Taiwan
关键词
D O I
10.1007/s12009-007-0035-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We compared the Acrysoft monofocal intraocular lens (IOL) in the mini monovision formula (n = 20) with the Array multifocal intraocular lens (n = 20) for glasses independence after cataract surgery. The Acrysoft monofocal IOL group showed similar and even slightly better results than the Array multifocal IOL group. The monofocal Acrysoft IOL using the mini monovision (blended vision) formula is a good alternative for providing post-cataract surgery glasses independence.
引用
收藏
页码:237 / 240
页数:4
相关论文
共 11 条
[1]   Comparison of a diffractive bifocal and a monofocal intraocular lens [J].
Allen, ED ;
Burton, RL ;
Webber, SK ;
Haaskjold, E ;
Sandvig, K ;
Jyrkkio, H ;
Leite, E ;
Nystrom, A ;
Wollensak, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (04) :446-451
[2]   MULTIFOCAL VERSUS MONOFOCAL INTRAOCULAR LENSES VISUAL AND REFRACTIVE COMPARISONS [J].
ELMAGHRABY, A ;
MARZOUKY, A ;
GAZAYERLI, E ;
VANDERKARR, M ;
DELUCA, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02) :147-152
[3]   Clear-lens extraction with multifocal lens implantation [J].
Fine, IH ;
Hoffman, RS ;
Packer, M .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 2001, 41 (02) :113-121
[4]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[5]   Contrast sensitivity and depth of focus with aspheric multifocal versus conventional monofocal intraocular lens [J].
Kamlesh, MS ;
Dadeya, S ;
Kaushik, S .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2001, 36 (04) :197-201
[6]   Multifocal versus monofocal intraocular lenses in cataract surgery [J].
Leyland, M ;
Zinicola, E .
OPHTHALMOLOGY, 2003, 110 (09) :1789-1798
[7]   Prospective randomised double-masked trial of bilateral multifocal, bifocal or monofocal intraocular lenses [J].
Leyland, MD ;
Langan, L ;
Goolfee, F ;
Lee, N ;
Bloom, PA .
EYE, 2002, 16 (04) :481-490
[8]   Accommodation obtained per 1.0 mm forward movement of a posterior chamber intraocular lens [J].
Nawa, Y ;
Ueda, T ;
Nakatsuka, M ;
Tsuji, H ;
Marutani, H ;
Hara, Y ;
Uozato, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2069-2072
[9]   PROSPECTIVELY RANDOMIZED TRIAL COMPARING THE PSEUDOACCOMMODATION OF THE AMO-ARRAY MULTIFOCAL LENS AND A MONOFOCAL LENS [J].
PERCIVAL, SPB ;
SETTY, SS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01) :26-31
[10]   PERFORMANCE OF DIFFRACTIVE MULTIFOCAL INTRAOCULAR LENSES IN EXTRACAPSULAR CATARACT-SURGERY [J].
ROSSETTI, L ;
CARRARO, F ;
ROVATI, M ;
ORZALESI, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (02) :124-128