Three-Year Outcomes Following Sirolimus- Versus Paclitaxel-Eluting Stent Implantation in an Unselected Population With Coronary Artery Disease (from the REWARDS Registry)

被引:17
作者
Hanna, Nicholas N. [1 ]
Gaglia, Michael A., Jr. [1 ]
Torguson, Rebecca [1 ]
Ben-Dor, Itsik [1 ]
Gonzalez, Manuel A. [1 ]
Collins, Sara D. [1 ]
Syed, Asmir I. [1 ]
Maluenda, Gabriel [1 ]
Kaneshige, Kimberly [1 ]
Xue, Zhenyi [1 ]
Satler, Lowell F. [1 ]
Kent, Kenneth M. [1 ]
Suddath, William O. [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
COLLABORATIVE NETWORK METAANALYSIS; LARGE 2-INSTITUTIONAL COHORT; RANDOMIZED CLINICAL-TRIALS; BARE-METAL STENTS; DIABETES-MELLITUS; COMPETING RISK; THROMBOSIS; EFFICACY; SAFETY;
D O I
10.1016/j.amjcard.2010.04.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Registry Experience at the Washington Hospital Center with Drug-Eluting Stents (REWARDS) study includes unselected patients with coronary artery disease treated with sirolimus-eluting stents (SESs; n = 2,392) or paclitaxel-eluting stents (PES; n = 1,119). This study aimed to examine the long-term safety profile of the 2 stents in a "real-world" population, especially in relation to stent thrombosis, and to compare differences in the diabetic cohort. Patients were followed for 3 years with regard to major adverse cardiac events (MACEs), including death, Q-wave myocardial infarction, and target lesion revascularization. Rates of stent thrombosis were also studied. Baseline characteristics were similar between stents. Although MACE rates at 3 years were similar (SES 28.1% vs PES 28.9%, p = 0.62), there was a significant difference in unadjusted rates of target lesion revascularization (SES 15.6% vs PES 12.6%, p = 0.03), death (SES 15.7% vs PES 19.0%, p = 0.02), and Q-wave myocardial infarction (SES 0.8% vs PES 2.1%, p = 0.003). After multivariable Cox regression to adjust for confounders, there was no significant difference in overall MACEs. Incidence of stent thrombosis was higher in the SES group (SES 2.2% vs PES 1.6%, p = 0.22), but this was not statistically significant (hazard ratio 1.6, 95% confidence interval 0.8 to 2.9, p = 0.17). Overall, diabetics had a higher MACE rate, but there was no difference between insulin-and noninsulin-dependent diabetics. In conclusion, at 3 years, PES and SES achieved similar results in MACEs and stent thrombosis. This should foster confidence that SES or PES can be compared to second-generation drug-eluting stents without concerns for safety or efficacy. (C) 2010 Elsevier Inc. All rights reserved. (Am J Cardiol 2010;106:504-510)
引用
收藏
页码:504 / 510
页数:7
相关论文
共 33 条
[1]   Late thrombosis of drug-eluting stents: A meta-analysis of randomized clinical trials [J].
Bavry, Anthony A. ;
Kumbhani, Dharam J. ;
Helton, Thomas J. ;
Borek, Przemyslaw P. ;
Mood, Girish R. ;
Bhatt, Deepak L. .
AMERICAN JOURNAL OF MEDICINE, 2006, 119 (12) :1056-1061
[2]   DEATH AND OTHER TIME-RELATED EVENTS AFTER VALVE-REPLACEMENT [J].
BLACKSTONE, EH ;
KIRKLIN, JW .
CIRCULATION, 1985, 72 (04) :753-767
[3]  
BODNAR E, 1979, BRIT HEART J, V42, P541
[4]   Comparable clinical outcomes with paclitaxel- and sirolimus-eluting stents in unrestricted contemporary practice [J].
Cosgrave, John ;
Melzi, Gloria ;
Corbett, Simon ;
Biondi-Zoccai, Giuseppe G. L. ;
Agostoni, Pierfrancesco ;
Babic, Rade ;
Airoldi, Flavio ;
Chieffio, Alaide ;
Sangiorgi, Giuseppe M. ;
Montorfano, Matteo ;
Michev, Iassen ;
Carlino, Mauro ;
Colombo, Antonio .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (24) :2320-2328
[5]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[6]  
Daemen Joost, 2006, EuroIntervention, V2, P330
[7]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[8]  
Dawkins Keith D, 2006, EuroIntervention, V2, P61
[9]   A proportional hazards model for the subdistribution of a competing risk [J].
Fine, JP ;
Gray, RJ .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1999, 94 (446) :496-509
[10]   Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice -: The SORT OUT II Randomized trial [J].
Galloe, Anders M. ;
Thuesen, Leif ;
Kelbaek, Henning ;
Thayssen, Per ;
Rasmussen, Klaus ;
Hansen, Peter R. ;
Bligaard, Niels ;
Saunamaki, Kari ;
Junker, Anders ;
Aaroe, Jens ;
Abildgaard, Ulrik ;
Ravkilde, Jan ;
Engstrom, Thomas ;
Jensen, Jan S. ;
Andersen, Henning R. ;
Botker, Hans E. ;
Galatius, Soren ;
Kristensen, Steen D. ;
Madsen, Jan K. ;
Krusell, Lars R. ;
Abildstrom, Steen Z. ;
Stephansen, Ghita B. ;
Lassen, Jens F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 299 (04) :409-416