Management principles of osteoporotic fractures

被引:10
作者
Gardner, Michael J. [1 ]
Collinge, Cory [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Med Ctr East South Tower, Nashville, TN 37205 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2016年 / 47卷
关键词
Fixation; Osteoporotic fractures; Locked plating; Augmentation; DISTAL FEMUR FRACTURES; BIOMECHANICAL EVALUATION; MECHANICAL EVALUATION; INTERNAL-FIXATION; COMPRESSION PLATE; MODEL; SCREW; NAIL; LCP;
D O I
10.1016/S0020-1383(16)47006-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Osteoporotic fractures are difficult to manage. They pose a number of difficulties to the surgeon arising from the underlying poor bone stock compromising the intention to achieve optimum fixation. Moreover, the frail elderly patients present with a variety of medical co-morbidities increasing the risk of developing perioperative complications. Despite these recognized challenges, there are currently a number of improving technologies and strategies at the surgeon's disposal to provide more confidence with fracture fixation and maximize the chance of success. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S33 / S35
页数:3
相关论文
共 20 条
[1]   Biomechanical evaluation of periprosthetic refractures following distal femur locking plate fixation [J].
Alexander, Jamie ;
Morris, Randal P. ;
Kaimrajh, David ;
Milne, Edward ;
Latta, Loren ;
Flink, Adam ;
Lindsey, Ronald W. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (12) :2368-2373
[2]   Failure of fixation of tibial plateau fractures [J].
Ali, AM ;
El-Shafie, M ;
Willett, KM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :323-329
[3]   Locking Plates for Extremity Fractures [J].
Anglen, Jeffrey ;
Kyle, Richard F. ;
Marsh, John Lawrence ;
Virkus, Walter W. ;
Watters, William C., III ;
Keith, Michael Warren ;
Turkelson, Charles M. ;
Wies, Janet L. ;
Boyer, Kevin M. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (07) :465-472
[4]  
[Anonymous], ORTH TRAUM ASS ANN M
[5]   Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model [J].
Collinge, Cory ;
Merk, Bradley ;
Lautenschlager, Eugene P. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (02) :124-128
[6]  
Cornell Charles N, 2003, J Am Acad Orthop Surg, V11, P109
[7]   The importance of medial support in locked plating of proximal humerus fractures [J].
Gardner, Michael J. ;
Weil, Yoram ;
Barker, Joseph U. ;
Kelly, Bryan T. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) :185-191
[8]   Influence of osteoporosis on fracture fixation - a systematic literature review [J].
Goldhahn, J. ;
Suhm, N. ;
Goldhahn, S. ;
Blauth, M. ;
Hanson, B. .
OSTEOPOROSIS INTERNATIONAL, 2008, 19 (06) :761-772
[9]   PMMA-augmented SI screw: a biomechanical analysis of stiffness and pull-out force in a matched paired human cadaveric model [J].
Grechenig, Stephan ;
Gaensslen, Axel ;
Gueorguiev, Boyko ;
Berner, Arne ;
Mueller, Michael ;
Nerlich, Michael ;
Schmitz, Paul .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 :S125-S128
[10]   Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate [J].
Heiney, Jake P. ;
Barnett, Michael D. ;
Vrabec, Gregory A. ;
Schoenfeld, Andrew J. ;
Baji, Avinash ;
Njus, Glen O. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02) :443-449