Improved scatter correction using adaptive scatter kernel superposition

被引:206
作者
Sun, M. [1 ]
Star-Lack, J. M. [1 ]
机构
[1] Varian Med Syst, Ginzton Technol Ctr, Mountain View, CA 94043 USA
关键词
CONE-BEAM-CT; X-RAY SCATTER; FLAT-PANEL IMAGER; GUIDED RADIATION-THERAPY; COMPUTED-TOMOGRAPHY; CORRECTION ALGORITHM; ANTISCATTER GRIDS; DETECTOR CT; ARTIFACT; QUALITY;
D O I
10.1088/0031-9155/55/22/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate scatter correction is required to produce high-quality reconstructions of x-ray cone-beam computed tomography (CBCT) scans. This paper describes new scatter kernel superposition (SKS) algorithms for deconvolving scatter from projection data. The algorithms are designed to improve upon the conventional approach whose accuracy is limited by the use of symmetric kernels that characterize the scatter properties of uniform slabs. To model scatter transport in more realistic objects, nonstationary kernels, whose shapes adapt to local thickness variations in the projection data, are proposed. Two methods are introduced: (1) adaptive scatter kernel superposition (ASKS) requiring spatial domain convolutions and (2) fast adaptive scatter kernel superposition (fASKS) where, through a linearity approximation, convolution is efficiently performed in Fourier space. The conventional SKS algorithm, ASKS, and fASKS, were tested with Monte Carlo simulations and with phantom data acquired on a table-top CBCT system matching the Varian On-Board Imager (OBI). All three models accounted for scatter point-spread broadening due to object thickening, object edge effects, detector scatter properties and an anti-scatter grid. Hounsfield unit (HU) errors in reconstructions of a large pelvis phantom with a measured maximum scatter-to- primary ratio over 200% were reduced from -90 +/- 58 HU(mean +/- standard deviation) with no scatter correction to 53 +/- 82 HU with SKS, to 19 +/- 25 HU with fASKS and to 13 +/- 21 HU with ASKS. HU accuracies and measured contrast were similarly improved in reconstructions of a body-sized elliptical Catphan phantom. The results show that the adaptive SKS methods offer significant advantages over the conventional scatter deconvolution technique.
引用
收藏
页码:6695 / 6720
页数:26
相关论文
共 38 条
[1]   Scatter correction for flat detector cone-beam CT based on simulated sphere models [J].
Bertram, M. ;
Hohmann, S. ;
Wiegert, J. .
MEDICAL PHYSICS, 2007, 34 (06) :2342-2343
[2]  
BRIESMEISTER J. F., 2000, MCNP GEN MONTE CARLO
[3]  
BROMBERG N, 1982, ACCEPTANCE TESTING R, P45
[4]   Accelerated simulation of cone beam X-ray scatter projections [J].
Colijn, AP ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :584-590
[5]  
Cranley K., 1997, CATALOGUE DIAGNOSTIC
[6]   Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype [J].
Daly, M. J. ;
Siewerdsen, J. H. ;
Moseley, D. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2006, 33 (10) :3767-3780
[7]   Advances in image-guided radiation therapy [J].
Dawson, Laura A. ;
Jaffray, David A. .
JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (08) :938-946
[8]   X-RAY TRANSMISSION FORMULA FOR ANTISCATTER GRIDS [J].
DAY, GJ ;
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (12) :1429-1433
[9]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[10]   Efficiency of antiscatter grids for flat-detector CT [J].
Kyriakou, Yiannis ;
Kalender, Willi .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6275-6293