BREATH-HOLD TARGET LOCALIZATION WITH SIMULTANEOUS KILOVOLTAGE/MEGAVOLTAGE CONE-BEAM COMPUTED TOMOGRAPHY AND FAST RECONSTRUCTION

被引:19
作者
Blessing, Manuel [1 ]
Stsepankou, Dzmitry [1 ]
Wertz, Hansjoerg [1 ]
Arns, Anna [1 ]
Lohr, Frank [1 ]
Hesser, Juergen [1 ]
Wenz, Frederik [1 ]
机构
[1] Heidelberg Univ, Med Fak Mannheim, Univ Med Ctr Mannheim, Dept Radiat Oncol, D-68167 Mannheim, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 78卷 / 04期
关键词
Image guidance; treatment verification; cone-beam computed tomography; CBCT; kilovoltage/megavoltage imaging; fast tomographic reconstruction; CT; RADIOTHERAPY; KILOVOLTAGE; THERAPY;
D O I
10.1016/j.ijrobp.2010.01.030
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90 within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180 degrees-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future. (C) 2010 Elsevier Inc.
引用
收藏
页码:1219 / 1226
页数:8
相关论文
共 50 条
  • [31] An offline technique to evaluate residual motion of the diaphragm during deep inspiratory breath-hold from cone-beam CT datasets
    Blessing, Manuel
    Hofmann, Julian
    Vogel, Lena
    Boda-Heggemann, Judit
    Lohr, Frank
    Wenz, Frederik
    Stieler, Florian
    Simeonova-Chergou, Anna
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (09) : 855 - 860
  • [32] Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: First clinical results
    Nijkamp, Jasper
    Pos, Floris J.
    Nuver, Tonnis T.
    De Jong, Rianne
    Remeijer, Peter
    Sonke, Jan-Jakob
    Lebesque, Joos V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 75 - 82
  • [33] Ultrafast single breath-hold cone-beam CT lung cancer imaging with faster linac gantry rotation
    Arns, Anna
    Wertz, Hansjoerg
    Boda-Heggemann, Judit
    Schneider, Frank
    Blessing, Manuel
    Abo-Madyan, Yasser
    Steil, Volker
    Wenz, Frederik
    Fleckenstein, Jens
    RADIOTHERAPY AND ONCOLOGY, 2019, 135 : 78 - 85
  • [34] Tetrahedron-based orthogonal simultaneous scan for cone-beam computed tomography
    Ye, Ivan B.
    Wang, Ge
    OPTICAL ENGINEERING, 2012, 51 (08)
  • [35] Anatomical localization of posterior superior alveolar artery: A retrospective study by cone-beam computed tomography
    Tofangchiha, Maryam
    Hematzadeh, Somayeh
    Vali, Mohammad Erfan
    Ghonche, Muhammad Reza Asgari
    Mirzadeh, Monirsadat
    Reda, Rodolfo
    Testarelli, Luca
    DENTAL AND MEDICAL PROBLEMS, 2022, 59 (03) : 407 - 412
  • [36] Investigation of effect of reconstruction filters on cone-beam computed tomography image quality
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 607 - 614
  • [37] PROSTATE LOCALIZATION ON DAILY CONE-BEAM COMPUTED TOMOGRAPHY IMAGES: ACCURACY ASSESSMENT OF SIMILARITY METRICS
    Kim, Jinkoo
    Hammoud, Rabih
    Pradhan, Deepak
    Zhong, Hualiang
    Jin, Ryan Y.
    Movsas, Benjamin
    Chetty, Indrin J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04): : 1257 - 1265
  • [38] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    JOURNAL OF DIGITAL IMAGING, 2023, 36 (01) : 250 - 258
  • [39] Interior Reconstruction from Truncated Projection Data in Cone-beam Computed Tomography
    Wang Xianchao
    Li Shaoyi
    Hou Changhui
    Journal of Digital Imaging, 2023, 36 : 250 - 258
  • [40] Fast Katsevich Algorithm Based on GPU for Helical Cone-Beam Computed Tomography
    Yan, Guorui
    Tian, Jie
    Zhu, Shouping
    Qin, Chenghu
    Dai, Yakang
    Yang, Fei
    Dong, Di
    Wu, Ping
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (04): : 1053 - 1061