Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals in environmental samples

被引:116
作者
Huang, Chaozhang [1 ]
Jiang, Zucheng [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
mesoporous titanium dioxide; flow injection; ICP-OES; on-line micro-column preconcentration; trace elements; environmental samples;
D O I
10.1016/j.talanta.2007.03.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals (Co, Cd, Cr, Cu, Mn, Ni, V, Ce, Dy, Eu, La and Yb) in environmental samples was described. Possessing a high adsorption capacity towards the metal ions, mesoporous titanium dioxide has found to be of great potential as an adsorbent for the preconcentration of trace metal ions in samples with complicated matrix. The experimental parameters including pH, sample flow rate, volume, elution and interfering ions on the recovery of the target analytes were investigated, and the optimal experimental conditions were established. Under the optimized operating conditions, a preconcentration time of 90 sand elution time of 18s with enrichment factor of 10 and sampling frequency of 20 h(-1) were obtained. The detection limits of this method for the target elements were between 0.03 and 0.36 mu g L-1, and the relative standard deviations (R.S.D.s) were found to be less than 6.0% (n =7, c =5 ng mL(-1)). The proposed method was validated using a certified reference material, and has been successfully applied for the determination of the afore mentioned trace metals in natural water samples and coal fly ash with satisfactory results. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:274 / 281
页数:8
相关论文
共 45 条
[1]   Selective water sorbents for multiple applications .2. CaCl2 confined in micropores of silica gel: Sorption properties [J].
Aristov, YI ;
Tokarev, MM ;
Restuccia, G ;
Cacciola, G .
REACTION KINETICS AND CATALYSIS LETTERS, 1996, 59 (02) :335-342
[2]   On-line preconcentration of some rare earth elements in water samples using C18-cartridge modified with 1-(2-pyridylazo) 2-naphtol (PAN) prior to simultaneous determination by inductively coupled plasma optical emission spectrometry (ICP-OES) [J].
Bahramifar, N ;
Yamini, Y .
ANALYTICA CHIMICA ACTA, 2005, 540 (02) :325-332
[3]   Determination of total mercury in whole blood by flow injection cold vapor atomic absorption spectrometry with room temperature digestion using tetramethylammonium hydroxide [J].
Barbosa, F ;
Palmer, CD ;
Krug, FJ ;
Parsons, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :1000-1005
[4]   A NEW FAMILY OF MESOPOROUS MOLECULAR-SIEVES PREPARED WITH LIQUID-CRYSTAL TEMPLATES [J].
BECK, JS ;
VARTULI, JC ;
ROTH, WJ ;
LEONOWICZ, ME ;
KRESGE, CT ;
SCHMITT, KD ;
CHU, CTW ;
OLSON, DH ;
SHEPPARD, EW ;
MCCULLEN, SB ;
HIGGINS, JB ;
SCHLENKER, JL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (27) :10834-10843
[5]   Development of an on-line preconcentration system for zinc determination in biological samples [J].
Dutra, RL ;
Maltez, HF ;
Carasek, E .
TALANTA, 2006, 69 (02) :488-493
[6]   DETERMINATION OF ARSENIC, CHROMIUM, SELENIUM AND VANADIUM IN BIOLOGICAL SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY USING ONLINE ELIMINATION OF INTERFERENCE AND PRECONCENTRATION BY FLOW-INJECTION [J].
EBDON, L ;
FISHER, AS ;
WORSFOLD, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :611-614
[7]   Functionalized monolayers on ordered mesoporous supports [J].
Feng, X ;
Fryxell, GE ;
Wang, LQ ;
Kim, AY ;
Liu, J ;
Kemner, KM .
SCIENCE, 1997, 276 (5314) :923-926
[8]   Lewis acid-containing mesoporous molecular sieves as solid efficient catalysts for solvent-free Mukaiyama-type aldol condensation [J].
Garro, R ;
Navarro, MT ;
Primo, J ;
Corma, A .
JOURNAL OF CATALYSIS, 2005, 233 (02) :342-350
[9]   Preconcentration and speciation of chromium in drinking water samples by coupling of on-line sorption on activated carbon to ETAAS determination [J].
Gil, RA ;
Cerutti, S ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
TALANTA, 2006, 68 (04) :1065-1070
[10]   Solar energy conversion by dye-sensitized photovoltaic cells [J].
Grätzel, M .
INORGANIC CHEMISTRY, 2005, 44 (20) :6841-6851