A thermoanalytical, X-ray diffraction and petrographic approach to the forensic assessment of fire affected concrete in the United Arab Emirates

被引:19
作者
Alqassim, M. A. [1 ]
Jones, M. R. [2 ]
Berlouis, L. E. A. [3 ]
Daeid, N. Nic [1 ]
机构
[1] Univ Dundee, Sch Sci & Engn, CAHID, Dow St, Dundee DD1 5EH, Scotland
[2] Univ Dundee, Sch Sci & Engn, Div Civil Engn, Concrete Technol Unit, Dundee DD1 4HN, Scotland
[3] Univ Strathclyde, Dept Pure & Appl Chem, WESTCHEM, 295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
关键词
Forensic investigation; Concrete; Fire; Thermal analysis; X-ray diffraction; Colour change; DAMAGED CONCRETE; REHYDRATION PROCESSES; THERMAL-ANALYSIS; CEMENT PASTE; TEMPERATURE; DEHYDRATION;
D O I
10.1016/j.forsciint.2016.03.015
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
For most fires, forensic investigation takes place well after building materials have cooled and knowledge of the structural damage due to heat exposure can reveal the temperature reached during an incident. Recently, there have been significant changes in the types and hence characteristics of cementitious materials used in the United Arab Emirates. Few studies focus on the application of thermo-analytical, X-ray diffraction and petrographic techniques on newly developed structures and this work aims to address this deficiency by utilising a series of parametric laboratory-based tests to assess the effects of heat on hardened concrete. Specimens were made with a design mix typically used for low-rise residential homes and storage facilities. The key constituents were: Portland cement (PC), crushed gabbro stone and dune sand with water/cement ratios of 0.4-0.5. Portland cement substitutes included ground granulated blast-furnace slag (GGBS), and silica fume (SF) at replacement percentages of up to 50% and 4%, respectively. The concrete cubes of 100-mm size were produced and standard cured to 28 days and then exposed to heat inside an electric furnace with pre-determined temperature regimes of 150 degrees C, 300 degrees C, 600 degrees C and 900 degrees C. Petrographic examination was utilised to compare the discolouration of the cooled concrete. Data derived from thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) are reported in order to assess the usefulness of these techniques in fire scene investigation to differentiate between these temperature regimes. The results from the TGA indicate that the majority of the percentage weight loss for all the mixtures occurred in the range 650-700 degrees C, which corresponds to the decarbonation of calcium carbonate, mainly from the aggregates. The endothermic DSC peak at 70-120 degrees C relates to the loss of evaporable water. Since both of these reactions are irreversible, this information can help fire investigators estimate the temperature history of concrete after exposure to fire. On the other hand, the portlandite in the cement matrix dehydroxylates at 450-550 degrees C but then reforms as the concrete cools. The onset temperature for the dehydroxylation of the reformed mineral is always lower than in virgin samples and its enthalpy furthermore depends strongly on the thermal history of the portlandite. Thus, this feature can be used to establish the temperature to which the material was exposed to during a fire incident. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 23 条
[1]  
Abu Saleh M., 2014, DEV SUSTAINABLE LOW
[2]   The use of thermal analysis in assessing the effect of temperature on a cement paste [J].
Alarcon-Ruiz, L ;
Platret, G ;
Massieu, E ;
Ehrlacher, A .
CEMENT AND CONCRETE RESEARCH, 2005, 35 (03) :609-613
[3]   Dehydration and rehydration processes of cement paste exposed to high temperature environments [J].
Alonso, C ;
Fernandez, L .
JOURNAL OF MATERIALS SCIENCE, 2004, 39 (09) :3015-3024
[4]   Methods to quantify the colour development of concrete exposed to fire [J].
Annerel, E. ;
Taerwe, L. .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (10) :3989-3997
[5]   Revealing the temperature history in concrete after fire exposure by microscopic analysis [J].
Annerel, E. ;
Taerwe, L. .
CEMENT AND CONCRETE RESEARCH, 2009, 39 (12) :1239-1249
[6]   Effects of elevated temperatures on properties of concrete [J].
Arioz, Omer .
FIRE SAFETY JOURNAL, 2007, 42 (08) :516-522
[7]   New NDT techniques for the assessment of fire-damaged concrete structures [J].
Colombo, Matteo ;
Felicetti, Roberto .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :461-472
[8]  
Elchalakani M., 2014, Case Stud. Constr. Mater., V1, P10, DOI DOI 10.1016/J.CSCM.2013.11.001
[9]  
Flick E.W., 1989, Handbook of Adhesives Raw Materials, V2nd
[10]  
Gabrovsek R, 2006, ACTA CHIM SLOV, V53, P159