Towards in field miniaturized liquid chromatography: Biocides in wastewater as a proof of concept

被引:8
作者
Cortes-Bautista, S. [1 ]
Navarro-Utiel, R. [1 ]
Ballester-Caudet, A. [1 ]
Campins-Falco, P. [1 ]
机构
[1] Univ Valencia, Dept Quim Analit, Fac Quim, MINTOTA Res Grp, Valencia 46100, Spain
关键词
Portable; Miniaturized liquid chromatography; Water analysis; Biocides; BETTER criteria; HEXAGON tool; SYSTEM;
D O I
10.1016/j.chroma.2022.463119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solving and/or evaluating given problems or decision making in place and in real time is a goal of the analytical chemistry science. In this context, the performance of a commercial portable miniaturized liquid chromatograph (minLC) with LED UV (255 nm) detector was compared with those provided by two lab minLCs (capillary and nano) coupled on-line to in-valve in-tube solid phase microextraction (IT-SPME) with diode array detector (DAD). In addition, responses of the portable LC for in-field analysis in several conditions were tested. Besides, two evaluation tools, BETTER criteria for portability and HEXAGON pictogram for sustainability and greenness were applied for comparison purposes. The benchtop LCs provided lower limits of detection (LODs) as expected, in the order of low mu g L -1 , than those achieved by the portable LC, with LODs around mg L -1 for compounds covering several polarities (logKow between -1.72 and 3.82). The used portable LC gave excellent resolution, reducing the analysis time and being the consumption of solvents negligible. As a practical application, fruit washing residual waters, which contained a suitable level of concentrations of several biocides for employing the portable minLC, were analyzed and quantified from the three minLCs as a proof of concept with comparable results. (c) 2022 The Authors. Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 29 条
[1]   On-site detection of fentanyl and its derivatives by field portable nano-liquid chromatography-electron lonization-mass spectrometry (nLC-EI-MS) [J].
Abonamah, Jocelyn V. ;
Eckenrode, Brian A. ;
Moini, Mehdi .
FORENSIC CHEMISTRY, 2019, 16
[2]  
Asensio-ramos M., 2017, Liquid Chromatography: Fundamentals and Instrumentation, P637
[3]   A new tool for evaluating and/or selecting analytical methods: Summarizing the information in a hexagon [J].
Ballester-Caudet, Ana ;
Campins-Falco, Pilar ;
Perez, Bibiana ;
Sancho, Raquel ;
Lorente, Monica ;
Sastre, Guadalupe ;
Gonzalez, Carina .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 118 :538-547
[4]   Portable liquid chromatograph for mobile laboratories .1. Aims [J].
Baram, GI .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :387-399
[5]  
Campns-Falc P., 2019, Encyclopedia of Analytical Science, P108, DOI DOI 10.1016/B978-0-12-409547-2.14218-0
[6]   Hand-portable HPLC with broadband spectral detection enables analysis of complex polycyclic aromatic hydrocarbon mixtures [J].
Chatzimichail, Stelios ;
Rahimi, Faraz ;
Saifuddin, Aliyah ;
Surman, Andrew J. ;
Taylor-Robinson, Simon D. ;
Salehi-Reyhani, Ali .
COMMUNICATIONS CHEMISTRY, 2021, 4 (01)
[7]   Zero electrical power pump for portable high-performance liquid chromatography [J].
Chatzimichail, Stelios ;
Casey, Duncan ;
Salehi-Reyhani, Ali .
ANALYST, 2019, 144 (21) :6207-6213
[8]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[9]   Portable capillary liquid chromatography for pharmaceutical and illicit drug analysis [J].
Foster, Samuel W. ;
Xie, Xiaofeng ;
Pham, Michelle ;
Peaden, Paul A. ;
Patil, Leena M. ;
Tolley, Luke T. ;
Farnsworth, Paul B. ;
Tolley, H. Dennis ;
Lee, Milton L. ;
Grinias, James P. .
JOURNAL OF SEPARATION SCIENCE, 2020, 43 (9-10) :1623-1627
[10]   A practical guide to analytical method validation, including measurement uncertainty and accuracy profiles [J].
Gustavo Gonzalez, A. ;
Angeles Herrador, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) :227-238