Highly Sensitive TiO2/Au/Graphene Layer-Based Surface Plasmon Resonance Biosensor for Cancer Detection

被引:79
|
作者
Mostufa, Shahriar [1 ]
Akib, Tarik Bin Abdul [1 ]
Rana, Md Masud [1 ]
Islam, Md Rabiul [2 ]
机构
[1] Rajshahi Univ Engn & Technol, Dept Elect & Elect Engn, Rajshahi 6204, Bangladesh
[2] Univ Wollongong, Sch Elect Comp & Telecommfiunicat Engn, Wollongong, NSW 2522, Australia
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 08期
关键词
cancer detection; surface plasmon resonance biosensor; FEM; angular interrogation; biosensor; numerical approach; REFRACTIVE-INDEX SENSOR; LABEL-FREE; NUMERICAL APPROACH; SPR BIOSENSOR; BREAST-CANCER; GRAPHENE; CELLS; ENHANCEMENT; PERFORMANCE; DESIGN;
D O I
10.3390/bios12080603
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a hybrid TiO2/Au/graphene layer-based surface plasmon resonance (SPR) sensor with improved sensitivity and capability for cancer detection is presented. The finite element method (FEM) was used for numerical analysis. The proposed SPR biosensor was structured based on the angular analysis of the attenuated total reflection (ATR) method for the detection of various types of cancer using the refractive index component. The resonance angle shifted owing to the increment of normal and cancerous cells' refractive index, which varied between 1.36 and 1.401 for six different types of normal and cancerous cells. According to numerical results, the obtained sensitivities for skin (basal), cervical (HeLa), adrenal gland (PC12), blood (Jurkat), and breast (MCF-7 and MDA-MB-231) cancer cells were 210 deg/RIU, 245.83 deg/RIU, 264.285 deg/RIU, 285.71 deg/RIU, 292.86 deg/RIU, and 278.57 deg/RIU, respectively. Furthermore, the detection accuracy (DA), figure of merits (EOM), and signal-to-noise ratio (SNR) were also obtained, with values of 0.263 deg(-1), 48.02 RIU-1, and 3.84, respectively. Additionally, the distribution of the electric field and the propagation of the magnetic field for resonant and non-resonant conditions of the proposed structure were illustrated. It was found that an enhanced field was exhibited on the surface of the plasmonic material for resonant conditions. We also measured the penetration depth of 180 nm using decayed electric field intensity. Furthermore, the impact of using a TiO2/Au/graphene layer was demonstrated. We further conducted analyses of the effects of the thickness of the gold layer and the effects of additional graphene layers on overall sensitivities for six different types of cancer. The proposed TiO2/Au/graphene layered structure exhibited the highest overall sensitivity in terms of detecting cancerous cells from healthy cells. Moreover, the proposed sensor was numerically analyzed for a wide range of biological solutions (refractive index 1.33-1.41), and the sensor linearity was calculated with a linear regression coefficient (R-2) of 0.9858. Finally, numerical results obtained in this manuscript exhibited high sensitivity in comparison with previously reported studies.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Surface Plasmon-Enhanced Photoelectrochemical Sensor Based on Au Modified TiO2 Nanotubes
    Liu, Wanqing
    Duan, Wei
    Jia, Liqun
    Wang, Siyu
    Guo, Yuan
    Zhang, Guoqing
    Zhu, Baolin
    Huang, Weiping
    Zhang, Shoumin
    NANOMATERIALS, 2022, 12 (12)
  • [42] High-Performance Tapered Fiber Surface Plasmon Resonance Sensor Based on the Graphene/Ag/TiO2 Layer
    Wang, Dan
    Li, Wei
    Zhang, Qinrong
    Liang, Benquan
    Peng, Zhenkai
    Xu, Jie
    Zhu, Chen
    Li, Jinze
    PLASMONICS, 2021, 16 (06) : 2291 - 2303
  • [43] The fiber surface plasmon resonance sensor based on TiO2 /Au-NPs sensitization
    Du, Hua-Long
    Kari, Nuerguli
    Li, Ben
    Wang, Qi
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [44] Localized Surface Plasmon Resonance-Based Label-Free Biosensor for Highly Sensitive Detection of Dopamine
    Choi, Jee-Hyun
    Lee, Jin-Ho
    Oh, Byung-Keun
    Choi, Jeong-Woo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (08) : 5658 - 5661
  • [45] Streptavidin-enhanced surface plasmon resonance biosensor for highly sensitive and specific detection of microRNA
    Decai Zhang
    Yurong Yan
    Wei Cheng
    Wei Zhang
    Yahui Li
    Huangxian Ju
    Shijia Ding
    Microchimica Acta, 2013, 180 : 397 - 403
  • [46] Hemoglobin detection in blood samples using a graphene-based surface plasmon resonance biosensor
    Karki, Bhishma
    Vasudevan, B.
    Uniyal, Arun
    Pal, Amrindra
    Srivastava, Vivek
    OPTIK, 2022, 270
  • [47] Design and Optimization of a Highly Sensitive Surface Plasmon Resonance Biosensor for Accurate Detection of Mycobacterium tuberculosis
    Mondal, Tanu Prava
    Mahmud, Russel Reza
    Rafi, Shah Ali
    Islam, M. Shariful
    Barua, Bobby
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9216 - 9223
  • [48] Sensitivity enhancement of surface plasmon resonance biosensor based on graphene and barium titanate layers
    Sun, Peng
    Wang, Mei
    Liu, Lili
    Jiao, Lipeng
    Du, Wei
    Xia, Feng
    Liu, Meijie
    Kong, Weijin
    Dong, Lifeng
    Yun, Maojin
    APPLIED SURFACE SCIENCE, 2019, 475 : 342 - 347
  • [49] Experimental and theoretical investigation for surface plasmon resonance biosensor based on graphene/Au film/D-POF
    Gong, Wei
    Jiang, Shouzhen
    Li, Zhen
    Li, Chonghui
    Xu, Jihua
    Pan, Jie
    Huo, Yanyan
    Man, Baoyuan
    Liu, Aihua
    Zhang, Chao
    OPTICS EXPRESS, 2019, 27 (03): : 3483 - 3495
  • [50] Optical Sensitive Detection of Cervical Cancer Based on Surface Plasmon Resonance Nanostructure
    Daher, Malek G.
    Trabelsi, Youssef
    Rashed, Ahmed Nabih Zaki
    Yahia, Ibrahim S.
    Prajapati, Yogenra Kumar
    Almawgani, Abdulkarem H. M.
    Alzahrani, Ahmad
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2024, 221 (16):