Measurement of the contralateral breast photon and neutron dose in breast cancer radiotherapy: A Monte Carlo study

被引:1
|
作者
Bagheri, Hamed [1 ]
Farhood, Bagher [2 ]
Mahdavi, Seied Rabi [3 ]
Shekarchi, Babak [1 ]
Manouchehri, Farhad [4 ]
Esfandbod, Malahat [5 ]
机构
[1] Aja Univ Med Sci, Radiat & Wave Res Ctr, Tehran, Iran
[2] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[3] Iran Univ Med Sci, Dept Med Phys, Tehran, Iran
[4] Radiat Applicat Sch, Nucl Sci & Technol Res Inst, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Fac Med, Tehran, Iran
关键词
Contralateral breast; Monte Carlo; neutron dose; physical wedge; radiotherapy; MODULATED RADIATION-THERAPY; 20-YEAR FOLLOW-UP; RANDOMIZED-TRIAL; CONSERVING SURGERY; DYNAMIC WEDGE; LYMPH-NODES; IRRADIATION; FIELD; IMRT; CONTAMINATION;
D O I
10.4103/jcrt.JCRT_1426_16
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: This study aimed to calculate the photon and neutron doses received to the contralateral breast (CB) during breast cancer radiotherapy for various field sizes in the presence of a physical wedge. Materials and Methods: Varian 2100 C/D linear accelerator was simulated using a MCNP4C Monte Carlo code. Then, a phantom of real female chest was simulated and the treatment planning was carried out on tumoral breast (left breast). Finally, the received photon and neutron doses to CB (right breast) were calculated in the presence of a physical wedge for 18 MV photon beam energy. These calculations were performed for different field sizes including 11 cm x 13 cm, 11 cm x 17 cm, and 11 cm x 21 cm. Results: The findings showed that the received doses (both of the photon and neutron) to CB in the presence of a physical wedge for 11 cm x 13 cm, 11 cm x 17 cm, and 11 cm x 21 cm field sizes were 9.87%, 12.91%, and 27.37% of the prescribed dose, respectively. In addition, the results showed that the received photon and neutron doses to CB increased with increment in the field size. Conclusion: From the results of this study, it is concluded that the received photon and neutron doses to CB in the presence of a physical wedge is relatively more, and therefore, they should be reduced to as low as possible. Therefore, using a dynamic wedge instead of a physical wedge or field-in-field technique is suggested.
引用
收藏
页码:1018 / 1023
页数:6
相关论文
共 50 条
  • [1] Measurement of the photon and thermal neutron doses of contralateral breast surface in breast cancer radiotherapy
    Bagheri, Hamed
    Firouzjah, Razzagh Abedi
    Farhood, Bagher
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (03) : 226 - 232
  • [2] MEASUREMENT OF THE CONTRALATERAL BREAST PHOTON AND THERMAL NEUTRON DOSES IN BREAST CANCER RADIOTHERAPY: A COMPARISON BETWEEN PHYSICAL AND DYNAMIC WEDGES
    Bagheri, Hamed
    Mahdavi, Seyed Rabie
    Shekarchi, Babak
    Manouchehri, Farhad
    Farhood, Bagher
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 73 - 81
  • [3] Patient-specific skin dose evaluation in breast cancer radiotherapy: A Monte Carlo study
    Atarod, Maryam
    Shami, Nahid
    Pourmoghaddas, Amir
    Saeb, Mohsen
    RADIATION PHYSICS AND CHEMISTRY, 2025, 231
  • [4] DOSE TO THE CONTRALATERAL BREAST FROM RADIOTHERAPY AND RISK OF SECOND PRIMARY BREAST CANCER IN THE WECARE STUDY
    Stovall, Marilyn
    Smith, Susan A.
    Langholz, Bryan M.
    Boice, John D., Jr.
    Shore, Roy E.
    Andersson, Michael
    Buchholz, Thomas A.
    Capanu, Marinela
    Bernstein, Leslie
    Lynch, Charles F.
    Malone, Kathleen E.
    Anton-Culver, Hoda
    Haile, Robert W.
    Rosenstein, Barry S.
    Reiner, Anne S.
    Thomas, Duncan C.
    Bernstein, Jonine L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1021 - 1030
  • [5] Dose perturbation in the radiotherapy of breast cancer patients implanted with the Magna-Site: a Monte Carlo study
    Chatzigiannis, Christos
    Lymperopoulou, Georgia
    Sandilos, Panagiotis
    Dardoufas, Constantinos
    Yakoumakis, Emmanouil
    Georgiou, Evaggelos
    Karaiskos, Pantelis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 58 - 70
  • [6] Calculation of organ doses from breast cancer radiotherapy: a Monte Carlo study
    Berris, T.
    Mazonakis, M.
    Stratakis, J.
    Tzedakis, A.
    Fasoulaki, A.
    Damilakis, J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 133 - 146
  • [7] Determining the contralateral breast dose during radiotherapy of breast cancer using rainbow dosimeter
    Rather, Sajad A.
    Haq, M. Mohib-ul
    Khan, Nazir A.
    Khan, Ajaz A.
    Sofi, A. G.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2014, 7 (04) : 384 - 389
  • [8] Simple shielding reduces dose to the contralateral breast during prone breast cancer radiotherapy
    Goyal, Uma
    Locke, Angela
    Smith-Raymond, Lexie
    Georgiev, Georgi N.
    MEDICAL DOSIMETRY, 2016, 41 (02) : 159 - 165
  • [9] Monte Carlo skin dose simulation in intraoperative radiotherapy of breast cancer using spherical applicators
    Moradi, F.
    Ung, N. M.
    Khandaker, M. U.
    Mahdiraji, G. A.
    Saad, M.
    Malik, R. Abdul
    Bustam, A. Z.
    Zaili, Z.
    Bradley, D. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16): : 6550 - 6566
  • [10] CANCER IN THE CONTRALATERAL BREAST AFTER RADIOTHERAPY FOR BREAST-CANCER
    BOICE, JD
    HARVEY, EB
    BLETTNER, M
    STOVALL, M
    FLANNERY, JT
    NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (12): : 781 - 785