摘要
Since the beginning of the Mars planet exploration, the characterization of carbon dioxide hypersonic flows to simulate a spaceship's Mars atmosphere entry conditions has been an important issue. We have developed a Tunable Diode Laser Absorption Spectrometer with a new room-temperature operating antimony-based distributed feedback laser (DFB) diode laser to characterize the velocity, the temperature and the density of such flows. This instrument has been tested during two measurement campaigns in a free piston tunnel cold hypersonic facility and in a high enthalpy arc jet wind tunnel. These tests also demonstrate the feasibility of mid-infrared fiber optics coupling of the spectrometer to a wind tunnel for integrated or local flow characterization with an optical probe placed in the flow.
引用
收藏
页码:6081 / 6091
页数:11
相关论文
共 13 条
  • [1] DIODE-LASER ABSORPTION TECHNIQUE FOR SIMULTANEOUS MEASUREMENTS OF MULTIPLE GASDYNAMIC PARAMETERS IN HIGH-SPEED FLOWS CONTAINING WATER-VAPOR
    ARROYO, MP
    LANGLOIS, S
    HANSON, RK
    [J]. APPLIED OPTICS, 1994, 33 (15): : 3296 - 3307
  • [2] Absorption sensor for CO in combustion gases using 2.3 μm tunable diode lasers
    Chao, X.
    Jeffries, J. B.
    Hanson, R. K.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (11)
  • [3] CHARBONNIER JM, 1997, P 87 SUP TUNN ASS MO
  • [4] CO2 concentration and temperature sensor for combustion gases using diode-laser absorption near 2.7 μm
    Farooq, A.
    Jeffries, J. B.
    Hanson, R. K.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2008, 90 (3-4): : 619 - 628
  • [5] Measurements of CO2 concentration and temperature at high pressures using 1f-normalized wavelength modulation spectroscopy with second harmonic detection near 2.7 μm
    Farooq, A.
    Jeffries, J. B.
    Hanson, R. K.
    [J]. APPLIED OPTICS, 2009, 48 (35) : 6740 - 6753
  • [6] FRANCOIS G, 1994, P 82 M SUP TUNN ASS
  • [7] LEFRANCOIS E, 2002, P AER THERM HIGH SPE, P57
  • [8] Meyers JM, 2009, THESIS U LIBRE BRUXE
  • [9] Tunable diode laser measurements on nitric oxide in a hypersonic wind tunnel
    Mohamed, A
    Rosier, B
    Henry, D
    Louvet, Y
    Varghese, PL
    [J]. AIAA JOURNAL, 1996, 34 (03) : 494 - 499
  • [10] The HITRAN 2008 molecular spectroscopic database
    Rothman, L. S.
    Gordon, I. E.
    Barbe, A.
    Benner, D. Chris
    Bernath, P. E.
    Birk, M.
    Boudon, V.
    Brown, L. R.
    Campargue, A.
    Champion, J. -P.
    Chance, K.
    Coudert, L. H.
    Dana, V.
    Devi, V. M.
    Fally, S.
    Flaud, J. -M.
    Gamache, R. R.
    Goldman, A.
    Jacquemart, D.
    Kleiner, I.
    Lacome, N.
    Lafferty, W. J.
    Mandin, J. -Y.
    Massie, S. T.
    Mikhailenko, S. N.
    Miller, C. E.
    Moazzen-Ahmadi, N.
    Naumenko, O. V.
    Nikitin, A. V.
    Orphal, J.
    Perevalov, V. I.
    Perrin, A.
    Predoi-Cross, A.
    Rinsland, C. P.
    Rotger, M.
    Simeckova, M.
    Smith, M. A. H.
    Sung, K.
    Tashkun, S. A.
    Tennyson, J.
    Toth, R. A.
    Vandaele, A. C.
    Vander Auwera, J.
    [J]. JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2009, 110 (9-10) : 533 - 572