Automated construction of an intraoperative high-dose-rate treatment plan library for the Varian brachytherapy treatment planning system

被引:5
作者
Deufel, Christopher L. [1 ]
Furutani, Keith M. [1 ]
Dahl, Robert A. [1 ]
Haddock, Michael G. [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, 200 1st St SW, Rochester, MN 55905 USA
关键词
Intraoperative; IOHDR; Brachytherapy; Sarcoma; Atlas; Library; Optimization; THERAPY HDR-IORT; RADIATION-THERAPY; RECTAL-CANCER; PART; OPTIMIZATION; MANAGEMENT; RATIONALE; DELIVERY; SARCOMAS; AAPM;
D O I
10.1016/j.brachy.2016.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The ability to create treatment plans for intraoperative high-dose-rate (IOHDR) brachytherapy is limited by lack of imaging and time constraints. An automated method for creation of a library of high-dose-rate brachytherapy plans that can be used with standard planar applicators in the intraoperative setting is highly desirable. METHODS AND MATERIALS: Nonnegative least squares algebraic methods were used to identify dwell time values for flat, rectangular planar applicators. The planar applicators ranged in length and width from 2 cm to 25 cm. Plans were optimized to deliver an absorbed dose of 10 Gy to three different depths from the patient surface: 0 cm, 0.5 cm, and 1.0 cm. Software was written to calculate the optimized dwell times and insert dwell times and positions into a.XML plan template that can be imported into the Varian brachytherapy treatment planning system. The user may import the.XML template into the treatment planning system in the intraoperative setting to match the patient applicator size and prescribed treatment depth. RESULTS: A total of 1587 library plans were created for IOHDR brachytherapy. Median plan generation time was approximately 1 minute per plan. Plan dose was typically 100% +/- 1% (mean, standard deviation) of the prescribed dose over the entire length and width of the applicator. Plan uniformity was best for prescription depths of 0 cm and 0.5 cm from the patient surface. CONCLUSIONS: An IOHDR plan library may be created using automated methods. Thousands of plan templates may be optimized and prepared in a few hours to accommodate different applicator sizes and treatment depths and reduce treatment planning time. The automated method also enforces dwell time symmetry for symmetrical applicator geometries, which simplifies quality assurance. (C) 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:531 / 536
页数:6
相关论文
共 50 条
  • [41] High-dose-rate brachytherapy in combination with conformal external beam radiotherapy in the treatment of prostate cancer
    Zwahlen, Daniel R.
    Andrianopoulos, Nick
    Matheson, Bronwyn
    Duchesne, Gillian M.
    Millar, Jeremy L.
    BRACHYTHERAPY, 2010, 9 (01) : 27 - 35
  • [42] A fast multitarget inverse treatment planning strategy optimizing dosimetric measures for high-dose-rate (HDR) brachytherapy
    Guthier, Christian V.
    Damato, Antonio L.
    Viswanathan, Akila N.
    Hesser, Juergen W.
    Cormack, Robert A.
    MEDICAL PHYSICS, 2017, 44 (09) : 4452 - 4462
  • [43] Fast and insightful bi-objective optimization for prostate cancer treatment planning with high-dose-rate brachytherapy
    Ngoc Hoang Luong
    Alderliesten, Tanja
    Pieters, Bradley R.
    Bel, Arjan
    Niatsetski, Yury
    Bosman, Peter A. N.
    APPLIED SOFT COMPUTING, 2019, 84
  • [44] A basic treatment equivalent for high-dose-rate gynaecological brachytherapy - A pilot study
    Vinod, SK
    Delaney, GP
    Jalaludin, BB
    Macleod, CA
    Fowler, AR
    Barton, MB
    CLINICAL ONCOLOGY, 2002, 14 (05) : 394 - 398
  • [45] High-Dose-Rate Brachytherapy for Primary Treatment of Refractory Proliferative Verrucous Leukoplakia of the Hard Palate
    Mohiuddin, Jahan J.
    Shanti, Rabie M.
    Alawi, Faizan
    Chang, Brian M.
    Marcel, Jaclyn
    Taunk, Neil K.
    Lukens, John N.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [46] High-dose-rate brachytherapy as part of a multidisciplinary treatment of nasopharyngeal lymphoepithelioma in childhood
    Nakamura, RA
    Novaes, PERD
    Antoneli, CBG
    Fogaroli, RC
    Pellizzon, ACA
    Ferrigno, R
    Maia, MAC
    Salvajoli, JV
    Pereira, AJ
    Nishimoto, IN
    CANCER, 2005, 104 (03) : 525 - 531
  • [47] Workflow efficiency for the treatment planning process in CT-guided high-dose-rate brachytherapy for cervical cancer
    Michaud, Anthony L.
    Benedict, Stanley
    Montemayor, Eliseo
    Hunt, Jon Paul
    Wright, Cari
    Mathai, Mathew
    Mayadev, Jyoti S.
    BRACHYTHERAPY, 2016, 15 (05) : 578 - 583
  • [48] In regard to: "Dosimetric verification of a high dose rate brachytherapy treatment planning system in homogeneous and heterogeneous media"
    Zwierzchowski, Grzegorz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 865 - 866
  • [49] Intraoperative high-dose-rate Brachytherapy (IBT) for locally unresectable intraabdominal malignancy
    Houtmeyers, Ph.
    Breusegem, C.
    Ceelen, W.
    Gillardin, J. M.
    De Putte, D. Van
    Boterberg, T.
    Van Eijkeren, M.
    Pattyn, P.
    ACTA CHIRURGICA BELGICA, 2007, 107 (05) : 523 - 528
  • [50] A comparative study on the accuracy of an automated multi-parameter high-dose-rate brachytherapy quality assurance system
    Zhang, Jing
    Jia, Mengyu
    Yuan, Zhiyong
    Qian, Shaowen
    Zhang, Daguang
    Wang, Wei
    RADIATION PHYSICS AND CHEMISTRY, 2024, 217